• Title/Summary/Keyword: $^{60}Co\{\gamma}-ray$

Search Result 273, Processing Time 0.026 seconds

The Effective Sterilization of White Ginseng Powder (인삼분말에 대한 살균방법 비교)

  • Seong, Hyeong-Sun;Park, Myeong-Han;Lee, Gwang-Seung
    • Journal of Ginseng Research
    • /
    • v.6 no.2
    • /
    • pp.143-148
    • /
    • 1982
  • This study was conducted to investigate to select the optimum condition for the sterilization of white ginseng powder. The powder heated at 100-121 $^{\circ}C$ for 1-30 minutes in a autoclave and irradiated at 2450 MHz microwave for 0.5-3.0 minutes was significantly changed in it's color density and become coagulated state, but their sterilizing effect on a general bacteria and 5. coli group were negligible. Meanwhile W- irradiation to the powder with thickness 1.5-10.5mm for 120 minutes was no changes in it's color. coagulated state and sterilizing effect, but 60Co-${\gamma}$ray irradiation at various dose with 0.1-2.0 Mrad was significant effect for sterilization and stability of the powder during the storage for 4 months at 25 $^{\circ}C$. The optimum dose of 60Co-${\gamma}$ ray irradiation was 0.5-0.7 Mrad.

  • PDF

Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size (수직형 다엽 콜리메이터의 방사선 조사면 크기 결정을 통한 유용성 연구)

  • Lee, Chang-Yeol;Son, Ki-Hong;Shin, Sang-Hun;Park, Seung-Woo;Lee, Dong-Han;Jung, Hai-Jo;Choi, Mun-Sik;Oh, Won-Young;Kim, Kum-Bae;Yang, Gwang-Mo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.3-11
    • /
    • 2011
  • The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.

A Study on the Development of Electronic Personal Dosimeter with Silicon PIN Photodiode (실리콘 핀 포토다이오드를 이용한 전자 선량계의 설계 및 구현)

  • Yi, Un-Kun;Kwon, Seok-Geon;Kim, Jung-Seon;Sohn, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2285-2288
    • /
    • 2002
  • Recently, electronic personal dosimeters based upon silicon PIN photodiode or miniature GM tube were developed and have attracted a lot of attention because of the advantages of their nature such as indication of dose rate and the cumulative dose, and facilitation of record keeping. In this paper, we have developed a high-sensitivity electronic personal dosimeter with silicon PIN photodiode. The electronic personal dosimeter is constructed with silicon PIN photodiode, preamplifier, and shaping amplifier. To show the effectiveness of electronic personal dosimeter, we conducted nuclear radiation experiments using $\gamma$-ray Ba-133, Cs-137, and Co-60. The electronic personal dosimeter have a good linearity on $\gamma$-ray energy and activity.

  • PDF

Study on Decomposition of Several Pesticides by Gamma-Irradiation (감마선 조사에 의한 농약 성분의 분해 연구)

  • Lee, Joo-Sang;Jung, Su-Yeon;Oh, Seung-Yeol;Jang, Beom-Su;Park, Sang Hyun
    • Journal of Radiation Industry
    • /
    • v.6 no.3
    • /
    • pp.205-209
    • /
    • 2012
  • The decomposition of 50 pesticides present in an aqueous solution using ${\gamma}-irradiation$ from a $^{60}Co$ gamma-ray source was investigated using laboratory-scale experiment. The rates of decomposition were determined using a gas chromatography-electron capture detector (GC-ECD), high-performance liquid chromatography-photo diode array detector (HPLC-PDA), and HPLC-fluorescence detector (FLD). When the initial concentration of pesticides was 10 ppm, and the radiation dose was 2, 5, 10, 20, and 30 kGy, respectively, 14 pesticide samples showed high removal rates (>50%) at absorbed doses of more than 10 kGy. With the exception of procymidone, they were all completely removed at a 30 kGy irradiation dose. These results provide fundamental data on the reactivity between gamma-irradiation and pesticides in an aqueous solution. Further, an evaluation of the toxicity of radiolytic intermediate products is required.

Gamma-ray Dosimetry with Thin Plastic Film

  • Yoo, Young-Soo;Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.223-233
    • /
    • 1973
  • Thirty two different kinds of domestic plastic films for use in measuring high gamma-ray dose have been collected and their dosimetric characteristics investigated with the help of a Co-60 gamma radiation source. Among them a rigid polyvinyl chloride(PVC) film of 0.06mm in thickness which is manufactured by Lucky Chemical Co., Korea, seem to be the most suitable one for this purpose. The relation between optical density at 3100$\AA$ and radiation exposure in this PVC film was linear in the range of 0.6$\times$10$^{6}$ R to 1.3$\times$10$^{7}$ R, and also the film showed a good reproducibility within 9% under the standard experimental condition. The effect of absorbed dose, oxygen content of surrounding atmosphere and irradiation temperature have also been studied for this film. It appeared to have a good property in the dosimetrical point of view.

  • PDF

A Study of Tissue-equivalent Compensator for 10MV X-ray and Co-60 Gamma-ray (고에너지 방사선치료용 조직등가보상체에 관한 고찰)

  • CHOI Tae Jin;HONG Young Rak;LIM Charn Soo;JEUNG Ho Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.1 no.1
    • /
    • pp.47-51
    • /
    • 1985
  • Authors describe some useful data when constructing tissue-equivalent compensators which would compensate tissue deficit in the treatment field of high energy electromagnetic radiation Tissue equivalent compensator is made of lucite. The ratio of compensator thickness to the thickness of tissue deficit depends on radiation energy, field size and the distance from the compensator to patient skin. When the compensator is separated from skin surface, the thickness ratio is always smaller than 1.0. This means that the larger the separation, the contribution to the total dose by means of scattered radiation from a tissue equivalent compensator is smaller. Authors propose that the thickness of lucite as tissue equivalent compensator is 0.57 times tissue deficit and the separation between compensator and skin is at least 15m for Co-60 gamma ray and 25cm for 10MV X-ray.

  • PDF

Flexible liquid light-guide-based radiation sensor with LaBr3:Ce scintillator for remote gamma-ray spectroscopy

  • Jae Hyung Park;Siwon Song;Seunghyeon Kim;Taeseob Lim;Jinhong Kim;Bongsoo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1045-1051
    • /
    • 2023
  • In this study, we fabricated a liquid light-guide-based radiation sensor with a LaBr3:Ce scintillator for remote gamma-ray spectroscopy. We acquired the energy spectra of Cs-137 and Co-60 using the proposed sensor, estimated the energy resolutions of the full energy peaks, and compared the scintillation light output variations. The major peaks of the radionuclides were observed in each result, and the estimated energy resolutions were similar to that of a general NaI(Tl) scintillation detector without a liquid light guide. Moreover, we showed the relationships of energy resolution and analog-to-digital channel regarding the number of photoelectrons produced and confirmed the effects of light guide length on remote gamma-ray spectroscopy. The proposed sensor is expected to be utilized to perform remote gamma-ray spectroscopy for distances of 3 m or more and would find application in many fields of nuclear facilities and industry.

Radiation-Induced Chromosome Aberration in Human Peripheral Blood Lymphocytes In Vitro : RBE Study with Neutrons and $^{60}Co\;{\gamma}-rays$. (KCCH cyclotron neutron 및 $^{60}Co\;{\gamma}-ray$에 의한 인체 말초혈액 임파구의 염색체 이상측정)

  • Kim, Sung-Ho;Kim, Tae-Hwan;Chung, In-Yong;Cho, Chul-Koo;Koh, Kyoung-Hwan;Yoo, Seong-Yul
    • Journal of Radiation Protection and Research
    • /
    • v.17 no.1
    • /
    • pp.21-30
    • /
    • 1992
  • The frequencies of KCCH cyclotron neutron (30 cGy/min) or $^{60}Co\;{\gamma}-rays$ (210 cGy/min)-induced asymmetrical interchanges (dicentrics and centric rings) and acentric fragments (deletion) at several doses were measured in the normal human peripheral blood lymphocytes Chromosome aberrations were scored at the first nitosis after stimulation with phytohemagglutinin. The neutron and y-ray data were analysed on linear, power-law, quadratic and linear-quadratic model . When the dicentrics and centric rings of ${\gamma}-rays$ datas were pooled and fitted to these model, good fits were obtained to power-law $[Y=(5.81{\pm}1.96){\times}10^6D^{1.93+0.06},\; P=0.931]$, quadratic $[Y=(3.91{\pm}0.09){\times}10^{-6}D^2,\;P=0.972]$ an linear-Quadrati model $[Y=(6.55{\pm}6.83){\times}10^{-5}D+(3.72{\pm}0.22){\times}10^{-6}D^2\; P=0.922]$, except for linear model (P=0.067) As in the case of neutron data, the best fit was obtained to the linear model $(Y=(6.12{\pm}0.17){\times}10^{-3}\;D-0.22,\;P=0.987]$ and good fits were obtained to power-law$[Y=(5.36{\pm}3.02) {\times}10^{-4}D^{1.42+0.11},\; P=0.601]$ and linear-quadratic model$[Y=(2.43{\pm}0.70){\times}10^{-3}D+(1.21{\pm}0.39){\times}10^{-7}D^2$, \;P=0.415], except for quadratic model (P<0.005). The relative biological effectiveness (RBE) of neutron compared with y-ray was estimated by best fitting model. In the asymmetrical interchanges range between 0.1 and 1.5 per cell, the RBE was found to be $2.714{\pm}0.408$.

  • PDF

Evaluations of Poly{vinyl alcohol)/Alginate Hydrogels Cross-linked by r-ray Irradiation Technique

  • Nam, Sang-Yong;Nho, Young-Chang;Chae, Gue-Tae;Jang, Hong-Seok;Suh, Tae-Suk;Ahn, Woong-Shick;Ryu, Kyu-Eun;Chun, Heung-Jae
    • Macromolecular Research
    • /
    • v.12 no.2
    • /
    • pp.219-224
    • /
    • 2004
  • In this work, we prepared hydrogels for wound dressing from a mixture of poly(vinyl alcohol) (PVA) and alginate using the $\^$60/Co ${\gamma}$-ray irradiation technique. We examined the physical properties of these hydrogels, including gelation, water absorptivity, and gel strength, to evaluate the applicability of these hydrogels for wound dressings. The biocompatibility of these hydrogels was also evaluated in vitro, in cultures of mouse fibroblasts, and in vivo, by subcutaneous implantation studies in rats. The gel content and strength increased upon increasing the radiation dose and upon decreasing the concentration of alginate. The degree of swelling was inversely proportional to the gel content and strength. The degree of cytotoxicity of the ${\gamma}$-ray-treated hydrogels was ca. 60% compared to the (-) control (serum) after 1 day of incubation. When the incubations were prolonged up to 2 days, the toxicity of all the samples decreased remarkably and reached that of the control. Subcutaneous implantation studies in rats indicated that foreign body reactions occurring around the implanted hydrogels were moderate and became minimal upon increasing the implantation time.

A Study of Gamma-ray Irradiation Effects on Commercially Available Single-mode Optical Fiber using Fiber Bragg Grating Sensor Systems (광섬유 브래그 격자 센서를 이용한 국내외 상용 단일모드 광섬유의 감마선 영향 연구)

  • Kim, Jong-Yeol;Lee, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.10
    • /
    • pp.2287-2292
    • /
    • 2012
  • In this study, $Co^{60}$ gamma-ray induced loss on Ge-doped single mode (SM) fiber has been measured. Gamma-ray is irradiated for 4 hours at the dose rate of 0.5 kGy/hr, 2 kGy/hr, 8 kGy/hr. Consequently, gamma-ray induced loss based on radiation effects in Ge-doped SM fiber occur significantly. Furthermore, dose rate effect was observed, that dose rate using the same total dose increased higher, then optical fiber loss increased more. Also annealing effect was observed, that the loss after irradiation, increased higher, then the recovery rate of loss was increased. This results are foreseen to be base data in the future radiation-hardened optical fiber study.