• 제목/요약/키워드: $^{244}Cm$

검색결과 155건 처리시간 0.03초

Transmutation of Am-241, 243 and Cm-244 in a Conventional Pressurized Water Reactor

  • Koh, Duck-Joon;Lee, Myung-Chan;Jeong, Woo-Tae;Boris P. Kochurov
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(3)
    • /
    • pp.423-428
    • /
    • 1996
  • The feasibility study on burning Am-241, 243 and Cm-244 nuclides in a conventional PWR (Pressurized Water Reactor) was carried out by using the TRIFON code that was developed by the Institute of Theoretical and Experimental Physics in Russia in 1992. TRIFON code uses updated ABBN Russian nuclear cross section library. The reference reactor is the Korea nuclear power plant unit 8 (YGN 2). The burning effect of Am-241, 243 and Cm-244 nuclides was studied with UO$_2$(3.5 w/o)fuel assembly and MOX (4.44 w/o) fuel assembly. The loaded mass ratio of Am-241, 243 and Cm-244 nuclides was obtained from the mass ratio of Am-241, 243 and Cm-244 nuclides in 10 year cooling spent fuel with average discharge burnup of 33 GWD/MTU. The effective transmutation rates of Am-241, 243 and Cm-244 nuclides in UO$_2$ fuel assembly were found to be higher than those in MOX fuel assembly. The result from TRIFON code was compared to that from CASMO-3/NEM-3D code system. For more reliable calculation of transmutation for MA(Minor Actinides) more sophisticated decay chain scheme of MA should be investigated and nuclear cross section library of MA should be considerably improved.

  • PDF

Investigations on the Pu-to-244Cm ratio method for Pu accountancy in pyroprocessing

  • Sunil S. Chirayath;Heukjin Boo;Seung Min Woo
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3525-3534
    • /
    • 2023
  • Non-uniformity of Pu and Cm composition in used nuclear fuel was analyzed to determine its effect on Pu accountancy in pyroprocessing, while employing the Pu-to-244Cm ratio method. Burnup simulation of a typical pressurized water reactor fuel assembly, required for the analysis, was carried out using MCNP code. Used fuel nuclide composition, as a function of nine axial and two radial meshes, were evaluated. The axial variation of neutron flux and self-shielding effects were found to affect the uniformity of Pu and Cm compositions and in turn the Pu-to-244Cm ratio. However, the results of the study showed that these non-uniformities do not affect the use of Pu-to-244Cm ratio method for Pu accountancy, if the measurement samples are drawn from the voloxidized powder at the feed step of pyroprocessing. 'Material Unaccounted For' and its uncertainty estimates are also presented for a pyrprocessing facility to verify safeguards monitoring requirements of the IAEA.

방사성폐기물 시료 중 $\^{241}$Am과 $\^{244}$Cm의 정량 (Determination of $^{241}$Am and $^{241}$Cm in Radwaste Samples)

  • 조기수;김태현;전영신;지광용;김원호
    • 방사성폐기물학회지
    • /
    • 제3권1호
    • /
    • pp.1-7
    • /
    • 2005
  • 방사성폐기물 시료 중 $^{241}$Am 과 $^{244}$Cm 을 정량하기 위하여 음이온교환수지 및 DTPA-lactic acid 용리액을 사용하는 HDEHP 추출크로마토그래피로 이들 핵종을 분리하였다 분리된 핵종은 황산염 매질에서 전착한 다음 알파분광분석법으로 각 핵종의 방사능을 측정하였다. 모의 시료용액 중 $^{241}$Am 및 $^{244}$Cm 을 측정한 결과 각각 85.2$\pm$ $17\% 및 86.3$\pm$ $15.3\%$ 의 회수율을 나타내었다. 본 방법을 방사성 농축폐액 시료에 적용하여 $^{241}$Am 과 $^{244}$Cm 을 정량한 결과 각각 1.5-1.9 Bq/g 및 -1.7 Bq/g 의 방사능 값을 나타내었다.

  • PDF

원전발생 방사성폐기물 시료 중 초우란원소의 정량 (Determination of Transuranic Elements in Radwaste Samples from Nuclear Power Plant)

  • 조기수;김태현;전영신;지광용;김원호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.351-357
    • /
    • 2003
  • 원전발생 방사성폐기물 시료 중 TRU를 정량하기위해 모의 사용 후 핵연료 시료 용액 중 Pu, Am 및 Cm 을 이온교환수지 및 HDEHP 추출크로마토그래피로 분리한 다음 알파분광분석법으로 각 핵종의 함량을 정량하였다. Dowex AG1 음이온수지 에서 12M HC1-0.lMHI 용리액으로 Pu를 분리하고 이차분리관인 HDEHP 흡착 분리 관에서 DTPA-Lactic Acid 용리액으로 Am과 Cm을 군분리하였다. 분리된 Pu, Am 및 Cm은 0.1M $NaHSO_4$-0.53M $Na_2SO_4$ 매질에서 전착한 다음 알파분광분석법으로 $^{239}Pu$, $^{241}Am$$^{244}Cm$의 알파에너지의 방사능을 측정하여 회수율을 추하였다. 비방사성 금속원소 및 우라늄을 포함하는 합성용액 시료중 $^{239}Pu$, $^{241}Am$$^{244}Cm$ 을 측정한 결과 각각 83.8%, 85.2% 및 86.3% 의 회수율을 나타내었다.

  • PDF

Nuclide composition non-uniformity in used nuclear fuel for considerations in pyroprocessing safeguards

  • Woo, Seung Min;Chirayath, Sunil S.;Fratoni, Massimiliano
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1120-1130
    • /
    • 2018
  • An analysis of a pyroprocessing safeguards methodology employing the Pu-to-$^{244}Cm$ ratio is presented. The analysis includes characterization of representative used nuclear fuel assemblies with respect to computed nuclide composition. The nuclide composition data computationally generated is appropriately reformatted to correspond with the material conditions after each step in the head-end stage of pyroprocessing. Uncertainty in the Pu-to-$^{244}Cm$ ratio is evaluated using the Geary-Hinkley transformation method. This is because the Pu-to-$^{244}Cm$ ratio is a Cauchy distribution since it is the ratio of two normally distributed random variables. The calculated uncertainty of the Pu-to-$^{244}Cm$ ratio is propagated through the mass flow stream in the pyroprocessing steps. Finally, the probability of Type-I error for the plutonium Material Unaccounted For (MUF) is evaluated by the hypothesis testing method as a function of the sizes of powder particles and granules, which are dominant parameters to determine the sample size. The results show the probability of Type-I error is occasionally greater than 5%. However, increasing granule sample sizes could surmount the weakness of material accounting because of the non-uniformity of nuclide composition.

Evaluation of nuclear material accountability by the probability of detection for loss of Pu (LOPu) scenarios in pyroprocessing

  • Woo, Seung Min;Chirayath, Sunil S.
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.198-206
    • /
    • 2019
  • A new methodology to analyze the nuclear material accountability for pyroprocessing system is developed. The $Pu-to-^{244}Cm$ ratio quantification is one of the methods for Pu accountancy in pyroprocessing. However, an uncertainty in the $Pu-to-^{244}Cm$ ratio due to the non-uniform composition in used fuel assemblies can affect the accountancy of Pu. A random variable, LOPu, is developed to analyze the probability of detection for Pu diversion of hypothetical scenarios at a pyroprocessing facility considering the uncertainty in $Pu-to-^{244}Cm$ ratio estimation. The analysis is carried out by the hypothesis testing and the event tree method. The probability of detection for diversion of 8 kg Pu is found to be less than 95% if a large size granule consisting of small size particles gets sampled for measurements. To increase the probability of detection more than 95%, first, a new Material Balance Area (MBA) structure consisting of more number of Key Measurement Points (KMPs) is designed. This multiple KMP-measurement for the MBA shows the probability of detection for 8 kg Pu diversion is greater than 96%. Increasing the granule sample number from one to ten also shows the probability of detection is greater than 95% in the most ranges for granule and powder sizes.

Spectral Reconstruction for High Spectral Resolution in a Static Modulated Fourier-transform Spectrometer

  • Cho, Ju Yong;Lee, Seunghoon;Kim, Hyoungjin;Jang, Won Kweon
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.244-251
    • /
    • 2022
  • We introduce a spectral reconstruction method to enhance the spectral resolution in a static modulated Fourier-transform spectrometer. The optical-path difference and the interferogram in the focal plane, as well as the relationship of the interferogram and the spectrum, are discussed. Additionally, for better spectral reconstruction, applications of phase-error correction and apodization are considered. As a result, the transfer function of the spectrometer is calculated, and then the spectrum is reconstructed based on the relationship between the transfer function and the interferogram. The spectrometer comprises a modified Sagnac interferometer. The spectral reconstruction is conducted with a source with central wave number of 6,451 cm-1 and spectral width of 337 cm-1. In a conventional Fourier-transform method the best spectral resolution is 27 cm-1, but by means of the spectral reconstruction method the spectral resolution improved to 8.7 cm-1, without changing the interferometric structure. Compared to a conventional Fourier-transform method, the spectral width in the reconstructed spectrum is narrower by 20 cm-1, and closer to the reference spectrum. The proposed method allows high performance for static modulated Fourier-transform spectrometers.