Determination of Transuranic Elements in Radwaste Samples from Nuclear Power Plant

원전발생 방사성폐기물 시료 중 초우란원소의 정량

  • Published : 2003.11.01

Abstract

Transuranic elements such as Pu, Am and Cm in synthetic solution of spent nuclear fuel samples were determined by electrodeposition followed by alpha-spectrometry after separation using anion exchange and extraction chromatography in order to determine the transuranic elements in radwaste samples from nuclear power plants. Plutonium was separated by 12M HC1-0.1M HI as an eluent on anion exchange column. As a second step Am and Cm were separated in a group by DTPA-Lactic acid as the eluent on HDEHP coated column. The nuclides of $^{239}Pu$, $^{241}Am$$^{244}Cm$ separated were determined by alpha-spectrometry after electrodeposition in 0.1M $NaHSo_4$-0.53M $Na_2SO_4$buffer solution as an electrolyte. The recovery yields of $^{239}Pu$, $^{241}Am$$^{244}Cm$ were 83.8%, 85.2% and 86.3%, respectively, from the synthetic solution containing uranium and non-radioactive metal elements.

원전발생 방사성폐기물 시료 중 TRU를 정량하기위해 모의 사용 후 핵연료 시료 용액 중 Pu, Am 및 Cm 을 이온교환수지 및 HDEHP 추출크로마토그래피로 분리한 다음 알파분광분석법으로 각 핵종의 함량을 정량하였다. Dowex AG1 음이온수지 에서 12M HC1-0.lMHI 용리액으로 Pu를 분리하고 이차분리관인 HDEHP 흡착 분리 관에서 DTPA-Lactic Acid 용리액으로 Am과 Cm을 군분리하였다. 분리된 Pu, Am 및 Cm은 0.1M $NaHSO_4$-0.53M $Na_2SO_4$ 매질에서 전착한 다음 알파분광분석법으로 $^{239}Pu$, $^{241}Am$$^{244}Cm$의 알파에너지의 방사능을 측정하여 회수율을 추하였다. 비방사성 금속원소 및 우라늄을 포함하는 합성용액 시료중 $^{239}Pu$, $^{241}Am$$^{244}Cm$ 을 측정한 결과 각각 83.8%, 85.2% 및 86.3% 의 회수율을 나타내었다.

Keywords