• Title/Summary/Keyword: $^{201}TI$

Search Result 59, Processing Time 0.022 seconds

TI-201 Redistribution SPECT and N-13 Ammonia PET Images in Patients with Old Myocardial Infarction and Left Ventricular Dysfunction: Segmental Comparison and Discordance Analysis (좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 TI-201 재분포 SPECT와 휴식기 N-13 Ammonia PET: 분절 비교 및 불일치 분석)

  • Choi, Joon-Young;Lee, Kyung-Han;Kim, Young-Hwan;Lee, Eun-Jeong;Chung, Hyun-Woo;Lee, Su-Jin;Lee, Sang-Hoon;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.218-224
    • /
    • 2004
  • We compared rest perfusion PET with redistribution perfusion SPECT to investigate the concordant rate between PET and SPECT images and analyze the discordant pattern. Materials and Methods: Rest N-13 ammonia and F-18 FDG PET were performed on 18 patients with old myocardial infarction and left ventricular dysfunction whose dipyridamole - 4hr redistribution TI-201 SPECT showed one or more severe fixed defects. Regional perfusion and metabolism were evaluated visually and quantitatively with 5-segment myocardial model. Results: There were high concordant rate in uptake pattern (80/90 segments, 88.9%) and high correlation coefficient on quantitative analysis (R=0.81, p<0.001) between redistribution TI-201 SPECT and N-13 ammonia PET images. Nine of 18 patients had SPECT-PET concordant pattern (Group I). Ten segments (9 in inferior wall, 1 in apex) from the remaining 9 patients showed SPECT-PET discordant pattern with abnormal TI-201 defect and near normal N-13 ammonia uptake (Group II). The diastolic and systolic left ventricular dimensions were significantly increased in Group II compared to those of Group I. When attenuation uncorrected N-13 ammonia PET images were reconstructed in Group II, it resulted in PET images with severe inferior wall defects nearly identical to those seen in redistribution TI-201 SPECT images. Conclusion: Redistribution TI-201 SPECT images showed high concordant rate and correlation with rest N-13 ammonia PET images. Most of discordant segments had fixed thallium defects in inferior wall with nearly normal N-13 ammonia uptake, which may result from severe left ventricular dilatation and attenuation by the left hemidiaphragm and cardiac blood pool.

Usefulness and Comparison of $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA Single Photon Emission Computed Tomography in Distinguishing Lung Cancer from Benign Lesion (폐암과 양성질환의 감별에 $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA 단일광자전산화단층촬영술의 비교 및 가치)

  • Kim, Chang Ho;Chae, Sang Cheol;Park, Jae Yong;Jung, Tae Hoon;Ahn, Byeong Cheol;Lee, Jae Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.720-727
    • /
    • 1996
  • Objectives: $^{201}TI$ - chloride, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA SPECT has been used in distinguishing lung cancer from benign lesion. To compare the diagnostic efficacy of SPECT with these tumor - seeking agents, we perfonned three consecutive SPECT using $^{201}TI$, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA in same subjects with a solitary pulmonary lesion. Methods: SPECT was carried out at 10min and 3hr for $^{201}TI$ after injection of 20mCi, and 2hr for $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA after injection of 20mCi, respectively, in 37 patients with a solitary pulmonary lesion(27 lung cancer and 10 benign diseases). In patients showing visual uptake on lesion site, we obtained the lesion - to - background(target lesion/contralateral normal lung) uptake ratio from transverse slice for each radionuclide and also calculated the retention index for $^{201}TI$. Results: The diagnostic sensitivity of $^{201}TI$, $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA SPECT to lung cancer was 100%, 96% and 73%, and the specificity was 40%, 70% and 70%, respectively. The low specificities for these agents were mainly due to high positive uptake in patients with active pulmonary tuberculosis. There were no significant differences in uptake ratios and retention index between malignant and benign lesions, and among the histologic types of lung cancer. Conclusion : $^{201}TI$ and $^{99m}Tc$ - MIBI showed higher sensitivity than $^{99m}Tc$(V) - DMSA for detecting lung cancer, but was of limited usefulness in distinguishing lung cancer from benign lesion due to low specificity, especially in area with a high prevalence of active pulmonary tuberculosis.

  • PDF

Myocardial Tracer Uptake in SPECT Images after Direct Intracoronary Injection Of TI-201: Comparison with Stress-Reinjection Images (관동맥내 주사 TI-201 SPECT에서 심근 분절의 섭취: 부하-재주사 TI-201 영상과의 비교)

  • Seo, Ji-Hyoung;Kang, Seong-Min;Bae, Jin-Ho;Lee, Yong-Jin;Lee, Sang-Woo;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Cho, Yong-Geun;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.4
    • /
    • pp.291-298
    • /
    • 2007
  • Purpose: To investigate the feasibility of TI-201 SPECT with intra coronary injection (lC-I) in the detection of viable myocardium, we have performed SPECT imaging after direct intracoronary injection of TI-201 and images were compared with those of stress-reinjection (Re-I) SPECT. Methods: Fourteen coronary artery disease patients (male 11, mean age 54 years) who had myocardial infarction or demonstrated left ventricular wall motion abnormality on echocardiography were enrolled. Three mCi of TI-201 was injected into both coronary arteries during angiography and images were acquired between 6- and 24-hour after injection. Reinjection imaging with 1 mCi of TI-201 was performed at 4-hour after adenosine stress imaging with 3 mCi of TI-201. Images were interpreted according to 4-grade visual scoring system (grade 0-3). Segments with mild to moderated uptake (${\leq}$grade 1), and upgraded more than one score with reinjection, and were defined as viable myocardium. Results: Image quality was poor in two cases with IC-I. Numbers of non-viable segments were 60 (23.8%) with IC-I, and 38 (15.1%) with Re-I, respectively. Overall agreement for perfusion grade per myocardial segment in each IC-I and Re-I was 76.5%. Overall agreement for viable segment between IC-I and Re-I was 90.5%. Only one out of 38 segments interpreted as non-viable with Re-I were interpretated as viable with IC-I. And 23 out of 214 segments interpreted as viable with Re-I were interpreted as non-viable with IC-I. Conclusion: Intracoronary TI-201 SPECT seemed to be not advantageous over stress-rest reinjection imaging in the assessment of myocardial viability, mainly due to low count statistics at 6-hour or 24-hour delayed time points. The feasibility of intracoronary TI- 201 SPECT is considered to be limited.

Scintigraphic Assessment of Myocardial Viability (신티그라피에 의한 심근생존능 평가)

  • Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.155-160
    • /
    • 1993
  • The identification of viable myocardium in patients with coronary artery disease and left ventricular dysfunction is an issue of increasing clinical relavance in the current era of myocardial revascularization. There are at least two forms of reversible myocardial dysfunction. Early reperfusion does not always lead to immediate functional improvement; rather, the return of contractility in tissue salvaged by reperfusion is delayed for hours, days or even weeks, a phenomenon that has been termed "stunned myocardium". Some patients with coronary artery disease show myocardial dysfunction at rest which are associated with reduced perfusion, and which disappear after revascularization; this phenomenon has been termed "hibernating myocardium". Recently, cardiac imaging techniques that evaluate myocardial viability on the basis of perfusion-contraction mismatch and inotropic reserve have gained substantial popularity and clinical success. This review focus on the application of $^{201}TI$ and $^{99m}Tc-MIBI$ to address myocardial viability in patients with hibernating and stunned myocardium. It is clear that 4-hour redistribution images of $^{201}TI$ underestimate ischemia and overestimate scar. Delayed imaging and reinjection imaging have been developed for the assessment of viability. Among many protocols suggested, stress-redistribution-reinjection imaging gained most popularity. Although $^{99m}Tc-MIBI$ could identify myocardial viability, $^{201}TI$ reinjection technique was regarded as superior to it. In conclusion, $^{201}TI$ stress, 4-hr rest redistribution, and reinjection imaging technique may be the most preferable method for evaluation of myocardial viability.

  • PDF

Properties of MTiO3 (M = Sr, Ba) and PbM'O3(M'= Ti, Zr) Superlattice Thin Films Fabricated by Laser Ablation

  • Lim, T.M.;Park, J.Y.;Han, J.S.;Hwang, P.G.;Lee, K.H.;Jung, K.W.;Jung, D.
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.201-204
    • /
    • 2009
  • $BaTiO_3/SrTiO_3$ and $PbTiO_3/PbZrO_3$ superlattice thin films were fabricated on $Pt/Ti/SiO_2/Si$ substrate by the pulsed laser deposition process. The morphologies and physical properties of deposited films were characterized by using X-ray diffractometer, HR-SEM, and Impedance Analyzer. XRD data and SEM images of the films indicate that each layer was well deposited alternatively in the superlattice structure. The dielectric constant of $BaTiO_3/SrTiO_3$ superlattice thin film was higher than that of individual $BaTiO_3$ or $SrTiO_3$ film. Same result was obtained in the $PbTiO_3/PbZrO_3$system. The dielectric constant of a superlattice film was getting higher as the number of layer is increased.

폴리머 애자의 자기세정 코팅을 위한 스퍼터링되어진 $TiO_2$ 박막의 특성

  • Park, Cheol-Min;Jeong, Ho-Seong;Lee, Jae-Hyeong;Seo, Mun-Su;Park, Yong-Seop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.201.1-201.1
    • /
    • 2013
  • 자기애자는 전차선로 설비에서 가장 중요한 전기절연재료이지만, 내충격에 결함이 있고 파괴되기 쉽고, 무거워 취급에 어려움이 따른다. 이러한 자기애자의 단점을 해결하기 위하여 고분자 애자의 개발이 진행되어지고 있다. 그러나 고분자 애자의 경우 재질 특성상 자기 애자보다 분진의 부착이 쉽고 부착된 분진의 세척이 어려운 단점이 있어, 장기 사용 시 특성 변화가 우려된다. 본 연구에서는 TiO2 세라믹 타겟이 부착된 비대칭 마그네트론 스퍼터링 장치를 이용하여 TiO2 박막을 증착하였으며 증착되어진 TiO2 박막의 광촉매 특성과 트라이볼로지 특성을 고찰하였다. 광촉매 특성으로는 표면 접촉각 분석을 통하여 고찰하였으며, 트라이볼로지 특성으로는 경도, 잔류응력, 마찰계수, 표면 거칠기 등을 평가하였다. 또한 XRD, FESEM 분석 등 구조분석을 통하여 광촉매 특성과 트라이볼로지 특성등과의 연관성을 규명하였다.

  • PDF

Numerical investigation of cyclic performance of frames equipped with tube-in-tube buckling restrained braces

  • Maalek, Shahrokh;Heidary-Torkamani, Hamid;Pirooz, Moharram Dolatshahi;Naeeini, Seyed Taghi Omid
    • Steel and Composite Structures
    • /
    • v.30 no.3
    • /
    • pp.201-215
    • /
    • 2019
  • In this research, the behavior of tube-in-tube BRBs (TiTBRBs) has been investigated. In a typical TiTBRB, the yielding core tube is located inside the outer restraining one to dissipate energy through extensive plastic deformation, while the outer restraining tube remains essentially elastic. With the aid of FE analyses, the monotonic and cyclic behavior of the proposed TiTBRBs have been studied as individual brace elements. Subsequently, a detailed finite element model of a representative single span-single story frame equipped with such a TiTBRB has been constructed and both monotonic and cyclic behavior of the proposed TiTBRBs have been explored under the application of the AISC loading protocol at the braced frame level. With the aid of backbone curves derived from the FE analyses, a simplified frame model has been developed and verified through comparison with the results of the detailed FE model. It has been shown that, the simplified model is capable of predicting closely the cyclic behavior of the TiTBRB frame and hence can be used for design purposes. Considering type of connection detail used in a frame, the TiTBRB member which behave satisfactorily at the brace element level under cyclic loading conditions, may suffer global buckling due to the flexural demand exerted from the frame to the brace member at its ends. The proposed TiTBRB suit tubular members of offshore structures and the application of such TiTBRB in a typical offshore platform has been introduced and studied in a single frame level using detailed FE model.

Friction and wear characteristics behaviors of TiN and CrN coating on SKD61 extrusion mold material for 6xxx Aluminium (6xxx계 알루미늄 압출용 SKD61 금형소재에 TiN, CrN의 마찰.마모 거동)

  • Kim, Min-Seok;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.201-202
    • /
    • 2009
  • 열간금형용강인 SKD61은 압출금형재로서 널리 사용되고 있으며, Al압출금형의 장수명화를 위한 방안으로 SKD61에 높은 경도를 갖는 TiN, CrN을 코팅하여 마모 시험을 실시하였다. 마모시험하중과 온도의 변화를 통해 각각의 코팅층의 마찰.마모 특성을 비교할 수 있었으며, 마모시험의 데이터는 직선왕복동 마모시험기를 사용하여 수집하였다.

  • PDF