대한핵의학회지 (The Korean Journal of Nuclear Medicine)
- 제38권3호
- /
- Pages.218-224
- /
- 2004
- /
- 1225-6714(pISSN)
좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 TI-201 재분포 SPECT와 휴식기 N-13 Ammonia PET: 분절 비교 및 불일치 분석
TI-201 Redistribution SPECT and N-13 Ammonia PET Images in Patients with Old Myocardial Infarction and Left Ventricular Dysfunction: Segmental Comparison and Discordance Analysis
- 최준영 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 이경한 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 김영환 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 이은정 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 정현우 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 이수진 (성균관대학교 의과대학 삼성서울병원 핵의학과) ;
- 이상훈 (성균관대학교 의과대학 삼성서울병원 순환기내과) ;
- 김병태 (성균관대학교 의과대학 삼성서울병원 핵의학과)
- Choi, Joon-Young (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Lee, Kyung-Han (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Kim, Young-Hwan (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Lee, Eun-Jeong (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Chung, Hyun-Woo (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Lee, Su-Jin (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Lee, Sang-Hoon (Department of Cardiovascular Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
- Kim, Byung-Tae (Department of Nuclear Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine)
- 발행 : 2004.06.30
초록
목적: 이 연구에서는 좌심실기능이상을 동반한 심근경색 병력이 있는 환자에서 생존 가능한 심근을 평가하기 위하여 시행한 휴식기 N-13 ammonia PET과 TI-201 재분포 SPECT를 분절단위로 비교해 보고, PET/SPECT 불일치를 일으키는 기전을 알아 보았다. 대상 및 방법 : 심근경색 병력과 좌심실기능이상, 그리고 약물 부하-휴식 TI-201 SPECT 상 1분절 이상의 고정관류결손이 있는 18명(남 17, 여 1; 나이
We compared rest perfusion PET with redistribution perfusion SPECT to investigate the concordant rate between PET and SPECT images and analyze the discordant pattern. Materials and Methods: Rest N-13 ammonia and F-18 FDG PET were performed on 18 patients with old myocardial infarction and left ventricular dysfunction whose dipyridamole - 4hr redistribution TI-201 SPECT showed one or more severe fixed defects. Regional perfusion and metabolism were evaluated visually and quantitatively with 5-segment myocardial model. Results: There were high concordant rate in uptake pattern (80/90 segments, 88.9%) and high correlation coefficient on quantitative analysis (R=0.81, p<0.001) between redistribution TI-201 SPECT and N-13 ammonia PET images. Nine of 18 patients had SPECT-PET concordant pattern (Group I). Ten segments (9 in inferior wall, 1 in apex) from the remaining 9 patients showed SPECT-PET discordant pattern with abnormal TI-201 defect and near normal N-13 ammonia uptake (Group II). The diastolic and systolic left ventricular dimensions were significantly increased in Group II compared to those of Group I. When attenuation uncorrected N-13 ammonia PET images were reconstructed in Group II, it resulted in PET images with severe inferior wall defects nearly identical to those seen in redistribution TI-201 SPECT images. Conclusion: Redistribution TI-201 SPECT images showed high concordant rate and correlation with rest N-13 ammonia PET images. Most of discordant segments had fixed thallium defects in inferior wall with nearly normal N-13 ammonia uptake, which may result from severe left ventricular dilatation and attenuation by the left hemidiaphragm and cardiac blood pool.
키워드