The Evaluation of SUV Variations According to the Errors of Entering Parameters in the PET-CT Examinations (PET/CT 검사에서 매개변수 입력오류에 따른 표준섭취계수 평가)

  • Kim, Jia;Hong, Gun Chul;Lee, Hyeok;Choi, Seong Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.43-48
    • /
    • 2014
  • Purpose: In the PET/CT images, The SUV (standardized uptake value) enables the quantitative assessment according to the biological changes of organs as the index of distinction whether lesion is malignant or not. Therefore, It is too important to enter parameters correctly that affect to the SUV. The purpose of this study is to evaluate an allowable error range of SUV as measuring the difference of results according to input errors of Activity, Weight, uptake Time among the parameters. Materials and Methods: Three inserts, Hot, Teflon and Air, were situated in the 1994 NEMA Phantom. Phantom was filled with 27.3 MBq/mL of 18F-FDG. The ratio of hotspot area activity to background area activity was regulated as 4:1. After scanning, Image was re-reconstructed after incurring input errors in Activity, Weight, uptake Time parameters as ${\pm}5%$, 10%, 15%, 30%, 50% from original data. ROIs (region of interests) were set one in the each insert areas and four in the background areas. $SUV_{mean}$ and percentage differences were calculated and compared in each areas. Results: $SUV_{mean}$ of Hot. Teflon, Air and BKG (Background) areas of original images were 4.5, 0.02. 0.1 and 1.0. The min and max value of $SUV_{mean}$ according to change of Activity error were 3.0 and 9.0 in Hot, 0.01 and 0.04 in Teflon, 0.1 and 0.3 in Air, 0.6 and 2.0 in BKG areas. And percentage differences were equally from -33% to 100%. In case of Weight error showed $SUV_{mean}$ as 2.2 and 6.7 in Hot, 0.01 and 0.03 in Tefron, 0.09 and 0.28 in Air, 0.5 and 1.5 in BKG areas. And percentage differences were equally from -50% to 50% except Teflon area's percentage deference that was from -50% to 52%. In case of uptake Time error showed $SUV_{mean}$ as 3.8 and 5.3 in Hot, 0.01 and 0.02 in Teflon, 0.1 and 0.2 in Air, 0.8 and 1.2 in BKG areas. And percentage differences were equally from 17% to -14% in Hot and BKG areas. Teflon area's percentage difference was from -50% to 52% and Air area's one was from -12% to 20%. Conclusion: As shown in the results, It was applied within ${\pm}5%$ of Activity and Weight errors if the allowable error range was configured within 5%. So, The calibration of dose calibrator and weighing machine has to conduct within ${\pm}5%$ error range because they can affect to Activity and Weight rates. In case of Time error, it showed separate error ranges according to the type of inserts. It showed within 5% error when Hot and BKG areas error were within ${\pm}15%$. So we have to consider each time errors if we use more than two clocks included scanner's one during the examinations.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF

Quantitative Evaluation of Regional Cerebral Blood Flow by Visual Stimulation in $^{99m}Tc-HMPAO$ Brain SPECT ($^{99m}Tc-HMPAO$ 뇌 SPECT에서 시각자극에 의한 국소 뇌 혈류변화의 정량적 검증)

  • Juh, Ra-Hyeong;Suh, Tae-Suk;Kwark, Chul-Eun;Choe, Bo-Young;Lee, Hyoung-Koo;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.3
    • /
    • pp.166-176
    • /
    • 2002
  • Purpose: The purpose of this study is to investigate the effects of visual activation and quantitative analysis of regional cerebral blood flow. Visual activation was known to increase regional cerebral blood flow in the visual cortex in occipital lobe. We evaluated that change in the distribution of $^{99m}Tc-HMPAO$ (Hexamethyl propylene amine oxime) to reflect in regional cerebral blood flow. Materials and Methods: The six volunteers were injected with 925 MBq (mean ages: 26.75 years, n=6, 3men, 3women) underwent MRI and $^{99m}Tc-HMPAO$ SPECT during a rest state with closed eyes and visual stimulated with 8 Hz LED. We delineate the legion of interest and calculated the mean count per voxel in each of the fifteen slices to quantitative analysis. The ROI to whole brain ratio and regional index was calculated pixel to pixel subtraction visual non-activation image from visual activation image and constructed brain map using a statistical parameter map (SPM99). Results: The mean regional cerebral blood flow was increased due to visual stimulation. The increase rate of the mean regional cerebral blood flow which of the activation region in primary visual cortex of occipital lobe was $32.50{\pm}5.67%$. The significant activation sites using a statistical parameter of brain constructed a rendering image and image fusion with SPECT and MRI. Conclusion: Visual activation was revealed significant increase through quantitative analysis in visual cortex. Activation region was certified in Talairach coordinate and primary visual cortex (Ba17),visual association area (Ba18,19) of Brodmann.

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Performance Evaluation of Reconstruction Algorithms for DMIDR (DMIDR 장치의 재구성 알고리즘 별 성능 평가)

  • Kwak, In-Suk;Lee, Hyuk;Moon, Seung-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.29-37
    • /
    • 2019
  • Purpose DMIDR(Discovery Molecular Imaging Digital Ready, General Electric Healthcare, USA) is a PET/CT scanner designed to allow application of PSF(Point Spread Function), TOF(Time of Flight) and Q.Clear algorithm. Especially, Q.Clear is a reconstruction algorithm which can overcome the limitation of OSEM(Ordered Subset Expectation Maximization) and reduce the image noise based on voxel unit. The aim of this paper is to evaluate the performance of reconstruction algorithms and optimize the algorithm combination to improve the accurate SUV(Standardized Uptake Value) measurement and lesion detectability. Materials and Methods PET phantom was filled with $^{18}F-FDG$ radioactivity concentration ratio of hot to background was in a ratio of 2:1, 4:1 and 8:1. Scan was performed using the NEMA protocols. Scan data was reconstructed using combination of (1)VPFX(VUE point FX(TOF)), (2)VPHD-S(VUE Point HD+PSF), (3)VPFX-S (TOF+PSF), (4)QCHD-S-400((VUE Point HD+Q.Clear(${\beta}-strength$ 400)+PSF), (5)QCFX-S-400(TOF +Q.Clear(${\beta}-strength$ 400)+PSF), (6)QCHD-S-50(VUE Point HD+Q.Clear(${\beta}-strength$ 50)+PSF) and (7)QCFX-S-50(TOF+Q.Clear(${\beta}-strength$ 50)+PSF). CR(Contrast Recovery) and BV(Background Variability) were compared. Also, SNR(Signal to Noise Ratio) and RC(Recovery Coefficient) of counts and SUV were compared respectively. Results VPFX-S showed the highest CR value in sphere size of 10 and 13 mm, and QCFX-S-50 showed the highest value in spheres greater than 17 mm. In comparison of BV and SNR, QCFX-S-400 and QCHD-S-400 showed good results. The results of SUV measurement were proportional to the H/B ratio. RC for SUV is in inverse proportion to the H/B ratio and QCFX-S-50 showed highest value. In addition, reconstruction algorithm of Q.Clear using 400 of ${\beta}-strength$ showed lower value. Conclusion When higher ${\beta}-strength$ was applied Q.Clear showed better image quality by reducing the noise. On the contrary, lower ${\beta}-strength$ was applied Q.Clear showed that sharpness increase and PVE(Partial Volume Effect) decrease, so it is possible to measure SUV based on high RC comparing to conventional reconstruction conditions. An appropriate choice of these reconstruction algorithm can improve the accuracy and lesion detectability. In this reason, it is necessary to optimize the algorithm parameter according to the purpose.

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.