• Title/Summary/Keyword: $^{123}In$

Search Result 7,594, Processing Time 0.037 seconds

Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects (분화 갑상선 암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교)

  • Lee, Hong-Je;Lee, Sang-Woo;Song, Bong-Il;Kang, Sung-Min;Seo, Ji-Hyoung;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.129-136
    • /
    • 2009
  • Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer(DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients(M:F = 55:443, Age $47.6{\pm}12.9$ years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq(5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients(88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients(11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue(4 patients) and cervical lymph node metastasis(3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC.

Flow Boiling of R-123/Oil Mixture in a Plain Tube Bundle (평활관군 내 R-123/오일의 흐름비등)

  • Lee, Jin-Wook;Lee, Jae-Ho;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.10
    • /
    • pp.704-709
    • /
    • 2010
  • The effect of oil on flow boiling of R-123 in a plain tube bundles was experimentally investigated for a range of quality and heat flux. It is shown that the heat transfer coefficient decreased as the oil concentration increased. Comparison with the previous pool boiling data reveals that the reduction of heat transfer coefficient by oil is more pronounced in pool boiling, and the difference increased with the increase of oil concentration and heat flux. Within the experimental range, the variation of mass flux or quality has negligible effect on the heat transfer coefficient.

Comparison Studies of SPECT Dopamine Transporter Imaging and Noninvasive Quantification using [Tc-99m]TRODAT-1 and [I-123]IPT ([Tc-99m]TRODAT-1과 [I-123]IPT SPECT를 이용한 도파민 운반체의 영상화 및 정량분석 비교)

  • Kim, Hee-Joung;Bong, Jung-Kyun;Lee, Hee Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.10-19
    • /
    • 1998
  • The SPECT radiopharmaceuticals labeled with I-123 for dopamine transporter imaging have been used to measure dopamine transporters in patients with movement disorders. However, a cyclotron produced I-123 limits its availiability and ease of use as a radioisotope to be labeled with pharmaceuticals in routine clinical diagnostic procedures. Recently, new radiophannaceuticals for Tc-99m which has optimal characteristic for SPECT imaging have been developed to overcome the limits of using I-123. The purpose of this study was to compare the quality of [Tc-99m]TRODAT-1 with [I-123]IPT SPECT data and then to evaluate the usefulness of [Tc-99m]TRODAT-1 SPECT by using three noninvasive simplified quantitative methods. TRODAT-1 labeled with Tc-99m($15.93{\pm}0.82mCi$) and IPT labeled with I-123($6.60{\pm}0.11mCi$) were injected into five normal controls. Dynamic [Tc-99m]TRODAT-1 SPECT scans of brain were performed for 10 minutes each over 180 minnutes, and for 20 minutes at 4 hrs and 5 hrs. [I-123]IPT SPECT scans were performed for 5 minutes each over 120 minutes. Time activity curves were generated for the left basal ganglia(LBG), right basal ganglia(RBG), and occipital cortex(OCC). Dopamine transporter parameters were ohtained using (BG-OCC)/OCC, graphical method($R_V$), and area ratio method($R_A$). TRODAT-1 and IPT SPECT imaging showed high uptake at the level of the basal ganglia. (BG-OCC)/OCC ratios for TRODAT-1 and IPT were $0.80{\pm}0.14$, and $3.22{\pm}0.81$, $R_Vs$ were $0.62{\pm}0.12$, and $2.30{\pm}0.35$, and $R_As$ were $0.37{\pm}0.08$ and $1.73{\pm}0.31$, respectively. In conclusion, further improvement of [Tc-99m]TRODAT-1 imaging characteristics may be required to estimate the dopamine transporter concentrations in human brains although it shows clear BG localization.

  • PDF

Seed melting during seeded-melt growth process of YBCO superconductors

  • Kim, Chan-Joong;Hong, Gye-Won;Kim, Ho-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.14-16
    • /
    • 2002
  • Melting and re-solidification nature of $SmBa_2Cu_3O_{7-y}$ (Sm123) grains in Ba-Cu-O (Ba:Cu=3:5) liquid containing 0.7 at.% yttrium were investigated at the temperature lower than its melt point. When Sm123 grains/liquid powder compacts were heated to a temperature between two melting points of Ba-Cu-O liquid ($1000^{\circ}C$) and a Sm123 phase ($1060^{\circ}C$) and held at this temperature for appropriate time, Sm123 grains melted partly in the liquid that was formed by melting of the liquid-forming powder. During subsequent slow cooling, (Sm,Y)$Ba_2Cu_3O_{7-y}$ solidified at the outer parts of the unmelted Sm12 grains, which is distinguished from the core regions by lower $Sm_2BaCuO_5$ (211) density.

  • PDF

Condensation Heat Transfer Characteristics of HCFC - 123 inside Horizontal Smooth Tube (HCFC-123의 수평 평활관내 응축 전열 특성에 관한 연구)

  • 권옥배;오후규;오종택;김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.3
    • /
    • pp.24-32
    • /
    • 1993
  • Experimental data on the heat transfer characteristics of HCFC-123 and CFC-11 during condensation in horizontal smooth tube are presented. The experimental apparatus consisted of a closed working fluid loop, coolant loop, and measuring system. The major components of the working fluid loop made of a refrigerant pump, boiler, superheater, refrigerant flow meter, receiver and test section. The tube-in-tube type test section was made of smooth tube which were constructed form 9.52 mm outer diameter of smooth copper tube with 50 mm outside diameter of PVC tube duct. The ranges of parameter, such as refrigerant mass velocity, coolant flow rate, and quality were 90-325kg/($m^2$.s), 60-360kg/h, 5-95% respectively. Data were obtained under steady state condition for annular flow. As a result of these, the condensation heat transfer coefficients for HCFC-123 were slightly lower than those of CFC-11 from 8% to 15% inside horizontal smooth tube. Furthermore, a new generalized correlation for the heat transfer coefficients of HCFC-123 and CFC-11 during condensation inside horizontal smooth tube is proposed.

  • PDF

Development of 1MW Organic Rankine Cycle System (1 MW급 유기랭킨 사이클 시스템 개발)

  • 박흥수;조한창;이용국
    • Journal of Energy Engineering
    • /
    • v.10 no.4
    • /
    • pp.318-326
    • /
    • 2001
  • To enhance thermal efficiency of thermal facility through recovery of low and medium temperature waste heat, 1 MW organic Rankine cycle system was designed and developed. The exhaust gases of 175$^{\circ}C$ at two 100 MW power plants in pohang steel works were selected as the representative of low and medium temperature waste heat in industrial process for the heat source of the organic Rankine cycle system. HCFC-123, a kind of harmless refrigerant, was chosen as the working fluid for Rankine cycle. The organic Rankine cycle system with selected exhaust gases and working fluid was designed and constructed. From the operation, it was confirmed that the organic Rankine cycle system is available for low and medium temperature waste heat recovery in industrial process. The optimum operating manuals, such as heat-up of hot water, turbine start-up, and the process of electric power generation, were derived. However, electric power generated was not 1 MW as designed but only 670 kW. It is due to deficiency of pump capacity for supply of HCFC-123. So it is necessary to increase the pump capacity or to decrease the pressure loss in pipe for more improved HCFC-123 supply.

  • PDF

Isolation, Identification, and Characterization of Pichia guilliermondii K123-1 and Candida fermentati SI, Producing Isoflavone β-Glycosidase to Hydrolyze Isoflavone Glycoside Efficiently, from the Korean Traditional Soybean Paste

  • Kim, Won-Chan;So, Jai-Hyun;Kim, Sang-In;Shin, Jae-Ho;Song, Kyung-Sik;Yu, Choon-Bal;Kho, Yung-Hee;Rhee, In-Koo
    • Journal of Applied Biological Chemistry
    • /
    • v.52 no.4
    • /
    • pp.163-169
    • /
    • 2009
  • A total of 155 microbial strains were isolated from the Korean traditional soybean paste based on their morphological features on the growth of agar plate. Among the isolated strains, a total of 28 strains were capable of hydrolyzing isoflavone glycoside to isoflavone aglycone efficiently in the soybean paste. Finally, two strains, K123-1 and SI, were selected because of their resistance to 15% NaCl and ability to convert isoflavone glycoside to isoflavone aglycone efficiently during the fermentation of soybean paste. The isolated strains K123-1 and SI were identified to be Pichia guilliermondii and Candida fermentati, respectively, using the partial 26S rDNA sequence analysis and phylogenic analysis. Pichia guilliermondii K123-1 and Candida fermentati SI converted daidzin to daidzein up to 96% and 95%, respectively, and genistin to genistein up to 92% when soybean pastes were fermented at $30^{\circ}C$ for 20 days with a single isolated strain. Pichia guilliermondii K123-1 and Candida fermentati SI were able to grow in the presence of 15% NaCl on both liquid medium and agar plate. We think that Pichia guilliermondii K123-1 and Candida fermentati SI might be one of good candidates for making functional soybean paste because they are isolated from the Korean traditional soybean paste and have a good ability to convert isoflavone glycosides to isoflavone aglycones and a high salt tolerance.

A Study of Lorentz-Meutzner's Two Evaporator Refrigeration System Using Alternative Refrigerant Mixtures (대체혼합냉매를 사용하는 Lorentz-Meutzner의 이중 증발기 냉동 시스템의 성능에 관한 연구)

  • Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.123-136
    • /
    • 1992
  • A preliminary thermodynamic design model of two-evaporator refrigerator/freezer system is constructed. This system is based on Lorentz-Meutzner cycle using refrigerant mixtures. This model screens alternative refrigerant (R32, R125, R143a, R22, R134a, R152a, R124, R142b, R123) mixtures to select the best performance-giving refrigerant mixtures and its composition for the system. Also, it estimates the effects of cooling temperatures of intercoolers, evaporator's area ratio, cooling load ratio on the performance of the system. The COP of the system ranges from 1.4 to 1.6, which is superior to that of the single evaporator system charged with R12 by 13% to 29%. Among 15 mixtures, R22/R123, R143a/R123, R32/R142b, and R32/R124 (in the order of high COP) are most recommendable. For the case of R22/R123, R22 mass fraction more than 0.5(Load Ratio=1.0) or 0.7(Load Ratio=0.33) is recomended in order to replace R12 without reduction in volumetric capacity when keeping the compressor as the same one. COP has the highest value with X(R22)=0.7 and 0.8, respectively. For the case of R143a/R123, in the similar manner, mass fraction of R143a is more than 0.5 or 0.6 while best performance occurs at X(R143a)=0.8. Higher temperature intercooler is more important for the performance of the system than lower temperature intercooler. The area ratio of evaporators is roughly proportional to load ratio of the evaporators.

  • PDF