• 제목/요약/키워드: $\rho$-power

검색결과 351건 처리시간 0.03초

PRT 시스템을 위한 무접촉전력전송 시스템 (A contactless power supply for the PRT system)

  • 노성찬;김수홍;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.895-902
    • /
    • 2005
  • This paper presents contactless power transfer system for an electric railway system which makes use of electromagnetic induction among the coils. A full bridge type series resonant inverter is used as a power conversion system. and MC14046 PLL of Motorola is used as a control device. Finally, presented system is verified by simulation.

  • PDF

m-분포 페이딩 환경하에서 부분대역 간섭을 받는 FH/MFSK신호의 오율특성 (Error Rate Performance of FH/MFSK Signal with Partial-Band Interference in m-distribution Fading Environment)

  • 강희조;조성준
    • 한국통신학회논문지
    • /
    • 제17권11호
    • /
    • pp.1320-1331
    • /
    • 1992
  • 부분대역 간섭 환경하에서 m-분포 페이딩 채널을 통해 수신되는 반복다이버시티 방식의 FH/MFSK 신호에 대한 오율식을 유도하고 이를 수치계산하여 비트 에너지 대 잡음 전력 밀도 비 $(E_b/N_0)$, 비트에너지 대 간섭 전력 밀도 비 $(E_b/N_1)$, 페이딩 지수(m), 부분대역 간섭의 대역 점유율$(\rho)$, 반복 정송수(L), 신호와 간섭 사이의 전력 상관계수 값을 함수로 하여 그림으로 나타내고 이를 분석했다. 본 논문에서는 이동무선 채널에서 발생하는 페이딩에 대처하기 위해 송신기에서 반복 전송 다이버시티를 사용할 때를 생각했는데 다이버시티를 사용할 때와 사용하지 않을 때의 오율을 비교한 결과 반복 전송 다이버시티가 페이딩에 매우 효과적이라는 것을 알 수 있었으며 다이버 시티 기법에 의해 얻어지는 오율의 개선정도를 알아내었다. 얻어진 결과로 부터 부분대역 간섭의 대역 점유율인 $\rho$가 작아지면 작아질수록 오율이 열화되는 것으로 보아 전대역 간섭보다는 부분대역 간섭의 영향이 더 크다는 것을 알 수 있었다. 아울러 $E_b/N_1$가 작고 $\rho$가 작을때는 페이딩의 심도가 깊으면 깊을수록 반복다이버 시티를 도입하므로서 오율특성의 개선이 현저하다는 것도 알수 있었다.

  • PDF

시험용 이상전원(異狀電源) 발생장치의 개발에 관한 연구 (A Study on the Development of Abnormal Power Source Generator to Evaluate Electronic Appliances)

  • 박찬원;노재관
    • 산업기술연구
    • /
    • 제24권A호
    • /
    • pp.83-90
    • /
    • 2004
  • Generally, electronic appliances are used on the basis of normal power source supply. The power source inevitably includes the abnormal condition, such as, sudden voltage sagging, power interrupt, and induced noises. As the electronic appliances which include micro-controller-based circuits are being increased recently, the controller circuit sometimes malfunctions by the abnormal condition of the power source. This situation causes serious problems such as hitch of electric appliance, fire and medical instrument glitch, which produces serious situations. In this paper, development of power interrupt tester which is highly suitable for an endurance test device under abnormal power source to microprocessor-based circuits is proposed 89C2051 microcontroller is performed to make power interrupt signal, and software controls peripheral hardwares and built-in functions. Experimental results of this study will offer a good application to electronic appliance maker as a test device of hardware and software debugging use.

  • PDF

엘리베이터 카 보조 전원을 위한 비접촉 전력전송 시스템 (Contactless power system for the elevator's car auxiliary power)

  • 임응규;노성찬;김수홍;김지민;김윤호;김은수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.49-51
    • /
    • 2007
  • 엘리베이터는 산업의 발전과 각종 건물의 고도화와 더불어 발전하여 왔다. 엘리베이터는 사람 또는 화물을 수송할 수 있는 카를 전동기를 통하여 견인하는 방식으로, 이동하는 카 내부에 전등 부하를 비롯한 공조시설, 제어설비 등 다양한 부하들이 존재한다. 지금까지의 엘리베이터는 전선을 사용하여 움직이는 카에 전원을 공급하는 방식을 사용함으로 부대설비가 복잡하여 지고 시공상에 어려움이 존재한다. 본 연구에서는 부대설비를 간소화하고 유지보수의 편리함을 제공하기 위하여 비접촉 전원장치를 이용한 이동하는 카에 전원을 공급하는 방식을 제안하고, 비접촉 전원장치에 사용되는 인버터와 변압기를 설계하여 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

다중일차권선 비접촉변압기를 이용한 비접촉 전원시스템의 공진주파수 추적에 관한 연구 (Study on resonant frequency tracking for contactless power system using multiple primary winding contactless transformer)

  • 김윤호;노성찬
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권3호
    • /
    • pp.182-188
    • /
    • 2006
  • Contactless power system is base on power transmission by magnetic force. The transformer loss is large because it separated with the gap. Also the system has unstable factor, since the parameters in the secondary can vary with the system movement. This paper proposes light train power transmission system using contactless transformer with multiple primary winding. To increase the system efficiency and to obtain the stable power transmission to the dynamic load, a resonant inverter is adopted. The proposed system was verified by the simulation using Spice and Maxwell. The designed contactless power transmission system is implemented for 5[kW] class and experimental results are discussed.

시동기의 정 출력 시동 기법에 의한 마이크로터빈 시동 구간의 운전 시뮬레이터 개발 (Simulator for a Micro-Turbine during Start-up by Constant Power Output Motoring Method using Starter)

  • 노민식
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2028-2037
    • /
    • 2009
  • This paper presents the simulator for dynamic modeling of a MT(micro turbine) during start-up period. The simulator is implemented by modeling a dynamic power of main components of a MT including compressor, combustor and turbine. A modeling for a MT under steady state operation can be accurately built from thermodynamics analysis. But dynamic modeling during start-up period is very difficult because efficiency of main components is very low and the designed value has big error and nonlinear characteristics during start-up. In this paper, new method without using thermodynamics analysis during start-up is proposed for the simulator. The power models of main components are derived from analysis of the experimental operation data by test motoring using a electric starter under constant power output. The simulator is developed using MATLAB/Simulink. For constant power output control, sensorless vector inverter is designed and algorithms for starting from stall and method for controling a output power are proposed. The performance of developed simulator is verified by comparing experimental and simulation start-up results.

3레벨 컨버터를 이용한 철도차량용 주 전력변환장치 (A Main Power Supply for Railway Vehicles using 3-level converters)

  • 노성찬;김윤호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2003년도 추계학술대회 논문집(III)
    • /
    • pp.646-652
    • /
    • 2003
  • AS a main Power Supply of the Railroad Vehicles, a three-Level ZVZCS DC/DC Converter is proposed in this paper. The proposed three-Level DC/DC Converter achieves zero voltage and zero current switching for the main switches. Its attribute is that the voltage across the switches is half the value of the input voltage. Also. using a diode and secondary side of the transformer, and simple auxiliary circuits it achieves zero current switching of the auxiliary switches. The principle operation and simulation results are included.

  • PDF

상관계수에 대한 검정법 비교 (A Comparative Study on Tests of Correlation)

  • 조현주;송명언;정동명;송재기
    • Journal of the Korean Data and Information Science Society
    • /
    • 제7권2호
    • /
    • pp.235-245
    • /
    • 1996
  • 확률변수 (X,Y)가 이변량 정규분포를 따르는 경우, 모상관계수 ${\rho}$에 관한 여러 가설들 중에서 $H_{0}:{\rho}={\rho}_{0}$인 경우에는 알려진 분포를 이용한 통계적 추론을 하기가 어렵다. 이러한 경우 Fisher에 의해 제안된 Z-변환을 이용한 근사적 검정법이 사용되어 오고 있으나 근사적인 방법이기 때문에 주어진 표본의 크기가 충분히 많지 않은 경우에는 적용에 무리가 있을 수 있다. 그래서 본 논문에서는 먼저 표본 상관계수 R의 분포를 모의실험을 통하여 직접 구하여 검정한 정확 검정법과, 붙스트랩(bootstrap) 방법을 이용하여 구한 붙스트랩 검정법을 제시하고, Fisher의 방법의 효율성과 실제성을 검토하고 제시된 방법들과 서로 비교하고자 한다.

  • PDF

비접촉 전력전송방식을 이용한 엘리베이터 카 보조 전원시스템 (Elevator's Car Auxiliary Power System using the Contactless Power Transmission Method)

  • 임응규;노성찬;김수홍;김지민;김윤호
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.80-84
    • /
    • 2008
  • 본 논문은 다중권선의 비접촉 변압기를 이용한 비접촉 전력공급 방식을 제안한 논문이다. 논문에서 제안한 전력공급 방식은 엘리베이터 카에 신뢰성 높은 전력을 전송하기 위하여 공진주파수 추적 기법을 사용하였다. 제안된 시스템을 검증하기 위하여 ICAP4와 Maxwell을 사용하여 시뮬레이션을 수행하였으며, 5[kW]급 비접촉 전력전송시스템을 제작하여 실험을 수행하였다.