• Title/Summary/Keyword: $\rho$-power

Search Result 351, Processing Time 0.01 seconds

Correlation Development on Critical Power in a Spherical Narrow Gap (구형 간극에서의 임계 출력에 대한 상관식 개발)

  • Park, Rae-Joon;Ha, Kwang-Soon;Kim, Sang-Baik;Kim, Hee-Dong;Jeong, Ji-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.235-240
    • /
    • 2001
  • The CHFG (Critical Heat Flux in Gap) test results have been evaluated to quantify the critical power in hemispherical narrow gaps and a new correlation has been developed. The CHFG test results have shown that increases in the gap thickness and pressure lead to an increase in critical power. The pressure effect on the critical power was found to be much milder than predictions by CHF correlations of other researches. From the CHFG test results, a new correlation on critical power in the hemispherical gap has been developed using the non-dimensional parameters as follows: $$\frac{qCHF}{{\rho}g^hfg}{\cdot}4\sqrt{\frac{{\rho}_g^2}{g{\sigma}{\Delta}{\rho}}=\frac{0.1042}{1+0.1375({\rho}g/{\rho}l)^{0.21}(D/s)}$$ The developed correlation has been expanded to apply the spherical geometry using the Siemens/KWU's correlation.

  • PDF

Predistorter Design for a Memory-less Nonlinear High Power Amplifier Using the $rho$th-Order Inverse Method for OFDM Systems ($rho$차 역필터 기법을 이용한 OFDM 시스템의 메모리가 없는 비선형 고전력 증폭기의 전치 보상기 설계)

  • Lim, Sun-Min;Eun, Chang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.191-199
    • /
    • 2006
  • In this paper, we propose a method to implement a predistorter of the $rho$-th order inverse filter structure to prevent signal distortion and spectral re-growth due to the high PAPR (peak-to-average ratio) of the OFDM signals and the non-linearity of high-power amplifiers. We model the memory-less non-linearity of the high-power amplifier with a polynomial model and utilize the inverse of the model, the $rho$-th order inverse filter, for the predistorter. Once the non-linearity is modeled with a polynomial, since we can determine the $rho$-th order inverse filter only with the coefficients of the polynomial, large memory is not required. To update the coefficients of the non-linear high-power amplifier model, we can use LMS or RLS algorithms. The convergence speed is high since the number of coefficients is small, and the computation is simple since manipulation of complex numbers is not necessary.

Relationship between Maximum Stem Volume and Density during a Course of Self-thinning in a Cryptomeria japonica Plantation

  • Ogawa, Kazuharu;Hagihara, Akio
    • The Korean Journal of Ecology
    • /
    • v.27 no.1
    • /
    • pp.27-33
    • /
    • 2004
  • Cryptomeria japonica plantation was monitored every year during 15 years from 1983 to 1997 for stem diameter and volume. The reciprocal equation, 1/Y = A + B/N, was applied to the relationship between cumulative volume Y and cumulative number N from the largest tree in the stand each year. The parameters A and B, which means respectively the reciprocal of an asymptotic value of total stand stem volume and the reciprocal of the maximum stem volume, are related by a power function. The power functional relationship between A and B derived a linear relationship of B-points ( $N_{B}$, $V_{B}$; $N_{B}$ = B/A, $Y_{B}$ = 1/2A) of each Y-N curve on log-log coordinates. The gradient of B-point line was so steep that the Y-N curve moved parallel upward year by year. The time trajectory of mean stem volume (W) and density ($\rho$) provided evidence in favor of the 3/2 power law of self-thinning, because the gradient of W - $\rho$ trajectory on log-log coordinates approximated to -3/2 at the final stage of stand development. On the basis of the results of Y-N curves and W - $\rho$ trajectory, the time trajectory of maximum stem volume $W_{max obs}$ and $\rho$ was derived theoretically. The gradient of $W_{max obs}$ - $\rho$ trajectory on log-log coordinates is calculated to be -0.6105 at the final stage. The gradient of $W_{max obs}$ - $\rho$ trajectory was steeper than that of W - $\rho$ trajectory at the early stage, while the former is gentler than the latter at the later stage.stage.e.age.e.

Bayesian Model Selection in the Unbalanced Random Effect Model

  • Kim, Dal-Ho;Kang, Sang-Gil;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.15 no.4
    • /
    • pp.743-752
    • /
    • 2004
  • In this paper, we develop the Bayesian model selection procedure using the reference prior for comparing two nested model such as the independent and intraclass models using the distance or divergence between the two as the basis of comparison. A suitable criterion for this is the power divergence measure as introduced by Cressie and Read(1984). Such a measure includes the Kullback -Liebler divergence measures and the Hellinger divergence measure as special cases. For this problem, the power divergence measure turns out to be a function solely of $\rho$, the intraclass correlation coefficient. Also, this function is convex, and the minimum is attained at $\rho=0$. We use reference prior for $\rho$. Due to the duality between hypothesis tests and set estimation, the hypothesis testing problem can also be solved by solving a corresponding set estimation problem. The present paper develops Bayesian method based on the Kullback-Liebler and Hellinger divergence measures, rejecting $H_0:\rho=0$ when the specified divergence measure exceeds some number d. This number d is so chosen that the resulting credible interval for the divergence measure has specified coverage probability $1-{\alpha}$. The length of such an interval is compared with the equal two-tailed credible interval and the HPD credible interval for $\rho$ with the same coverage probability which can also be inverted into acceptance regions of $H_0:\rho=0$. Example is considered where the HPD interval based on the one-at- a-time reference prior turns out to be the shortest credible interval having the same coverage probability.

  • PDF

A Wilcoxon signed-rank test for random walk hypothesis based on slopes (기울기를 이용한 랜덤워크 윌콕슨 부호순위검정)

  • Kim, Tae Yoon;Park, Cheolyong;Kim, Seul Gee;Kim, Min Seok;Lee, Woo Jung;Kwon, Yunji
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.6
    • /
    • pp.1499-1506
    • /
    • 2014
  • Random walk is used for describing random phenomenon in various areas but tests for random walk developed so far are known to suffer from size distortion and low power. Kim et al. (2014) proposed a sign test for unit root (${\rho}=1$) hypothesis based on slopes. This article proposes a Wilcoxon signed rank test based on slopes for unit root hypothesis, and compares it with the augmented Dickey-Fuller test and the sign test by a simulation study. Our results confirm that the nonparametric tests are better than ADF test for small samples like n = 30. The results also show that the sign test is better than the Wilcoxon signed rank test and that for 0 < ${\rho}$ < 1 (-1 < ${\rho}$ < 0), the nonparametric tests suffer from power loss (improvement) as normal error changes to double exponential error.

Effect of Injection Parameters on Diesel Spray Characteristics (디젤분무 특성에 미치는 분사인자의 영향)

  • Sim Song-Cheol;Jung Byung-Kook;Ahn Byoung-Kyu;Kim Jang-Hein;Jung Jae-Yeon;Song Kyu-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • The characteristics of diesel spray have effect on the engine Performance such as power. fuel consumption and emissions. Therefore, This study was Performed to investigate the effect of various injection parameters. In this study. the experiment is performed by using the high temperature and high pressure chamber. Spray behaviors are visualized by using the high speed camera and spray angle. Penetration etc. are measured. Experimental results are summarized as follows ; 1) Correlations of spray Penetration is expressed as follows $$0 $$t_b 2) Correlations of spray Angle is expressed as follows $$T_a=293K \;;\; tan({\theta}/2)=0.59({\rho}_a/{\rho}_f)^{0.437}$$ $$T_a=473K\;;\; tan({\theta}/2)=0.588({\rho}_a/{\rho}_f)^{0.404}$$ 3) The measured macro characteristics - spray tip penetration and spray angle agreed well with established correlations.

Effect of the Injection Parameters on Diesel Spray Characteristics

  • Song Kyu Keun;Sim Sang Cherl;Jung Byong Koog;Kim Hyung Gon;Kim Jang Heon
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.1321-1328
    • /
    • 2005
  • The characteristics of the diesel spray have affected certain aspects of engine performance, such as the power, fuel consumption, and emissions. Therefore, this study was performed to investigate the effects of various injection parameters. In order to obtain the effect of injection parameters on diesel spray characteristics, the experiment is performed by using a high temperature and pressure chamber. The behaviors of the spray are visualized by using a high speed video camera, spray angle, penetration, and various other things. The results of the experiment are summarized as follows. (1) The correlation of the spray penetration can be expressed as follows. $$0< t $$t_{b} (2) The correlation of the spray angle can be expressed as follows $$T_a=293K\;tan({\theta}/2)=0.59({\rho}a/{\rho}f)^{0.437}$$ $$T_a=473K\;tan({\theta}/2)=0.588({\rho}a/{\rho}f)^{0.404}$$ (3) The measured macro characteristics that include the spray tip penetration and spray angle corresponded with the established correlations.

Research on the Relation between Transformer Oil Flow Electrification and Electrostatic Current

  • Fu, Qiang;Wang, Rui;Zou, Pinguo;Li, Zhao;Yang, Yang;Xie, Xuejun
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.610-615
    • /
    • 2015
  • In order to study and obtain the mathematical relation between the electrification degree of transformer oil flow and the electrostatic current, a small amount of data about the electrification degree of oil flow and the corresponding electrostatic current is studied by linear regression method and grey model method. The results show that the linear correlation between the electrification degree and the electrostatic current was not good, and the relation between the electrification degree of oil flow and electrostatic current (i) could be expressed as ${\rho}(0)=0.2049\;i^{(0)}+169.4419$ according to grey model GM (0, 2) when the electrification degree of oil flow is represented by the charge number generated from transformer oil per unit volume, namely the charge density (${\rho}$).

Hybrid Active Filter System for High Power Non-linear Loads (비선형 부하를 위한 복합전력필터)

  • Kang Min-Su;Rho Youn-Sung;Kim Soo-Gon;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.182-185
    • /
    • 2003
  • Proposed Hybrid System is composed of phase leading capacitor banks, LC passive filters and active power filter. The passive power filter in parallel connection eliminate the 5th and 7th harmonics. The Variable capacitor banks correct the most of power factor, and the active power filter takes charge of remainder,

  • PDF

INCLUSION THEOREMS INTO THE SPACE MΨ.

  • Lee, Chong-Sung;Cho, Kyu-Geun
    • Journal of applied mathematics & informatics
    • /
    • v.5 no.3
    • /
    • pp.877-888
    • /
    • 1998
  • We show that if dialation operator $\parallel\sigma_r\parallel\; E=\Psi(r)$ of E, then $\Lambda_\subset_{\Psi1}E\subset\;M_\Psi$, We also show that there are lattice-isomorphic copies of $l_\rho \; and \;l_\infty$ in $M \Psi$ under some condition.