• Title/Summary/Keyword: $\beta$-TCP

Search Result 114, Processing Time 0.028 seconds

Processing and Properties of 30 wt% β-Tricalcium Phosphate/Al2O3 Composites (30 wt% β-Tricalcium Phosphate/Al2O3 복합재료의 제조 및 특성)

  • Jeong, Heecheol;Ha, Jung-Soo
    • Korean Journal of Materials Research
    • /
    • v.28 no.3
    • /
    • pp.142-147
    • /
    • 2018
  • ${\beta}-Tricalcium$ phosphate (TCP) was added to $Al_2O_3$ to make a biomaterial with good mechanical properties. Using a TCP powder synthesized by a polymer complexation method, $Al_2O_3$ composites containing 30 wt% TCP were fabricated and characterized for densification, phase, microstructure, strength, and fracture toughness. With optimizing the powder preparation conditions, a high densification of 97 % was obtained by sintering at $1350^{\circ}C$ for 2 h. No reaction between the two components occurred and there was no transition to ${\alpha}-TCP$. TCP grains with a size of $2-4{\mu}m$ were well surrounded by $Al_2O_3$ grains with a size of $1{\mu}m$ or less. Strength 61(Brazilian) or 187(3-p MOR) MPa, and fracture toughness 1.7 (notched beam) or 2.5 (indentation) $MPa{\cdot}m^{1/2}$ were obtained, which are large improvements over the strength of $TCP/Al_2O_3$ composites and toughness of TCP and hydroxyapatite in previous studies.

Properties of the Ceramic Composites and Glass-Ceramics Prepared by Using the Natural Hydroxyapatite Derived from Tuna bone (참치 뼈에서 추출한 천연 Hydroxyapatite를 이용한 세라믹 복합체 및 Glass-Ceramics의 특성)

  • Choi, Jin-Sam;Lee, Chang-Kook;Jeon, You-Jin;Byun, Hee-Guk;Kim, Se-Kwon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.394-399
    • /
    • 1999
  • As the prosthetic application of natural mineral substituted for chemical reagent, composites and a glass-ceramics containing hydro-xyapatite isolated from tuna bone were prepared by solid state reaction. On x-ray examinations, the major phases of composites were identified as pseudowollastonite(${\alpha}-CaSiO_3$) and ${\beta}$-tricalcium phosphate($\beta$-TCP) and the phase of a glass-ceramics was observed as $\beta$-TCP and fluoroapatite caused by $CaF_2$ respectively. SEM images depict that the microstructures of grain at the composites were a function of temperature. The measured strength of a glass-ceramics prepared at $900^{\circ}C$ for 4 hr in air was 90 MPa as a 4-point bending method and this value was similar to the cortical bone, as 50~150 MPa but it was lower than its maximum strength.

  • PDF

A Study on Performance Parameter of TCP Vegas (TCP Vegas의 성능 파라미터에 관한 연구)

  • Pyo, Ji-Hun;Chung, Yun-Sick;Lim, Seog-Ku
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.290-292
    • /
    • 2007
  • 인터넷의 안정성에 가장 큰 영향을 미치는 요소는 종단간에 이루어지는 TCP 혼잡제어이다. 현재 TCP Vegas가 효율성과 안정성 측면에서 TCP Reno보다 우수함에도 불구하고, TCP Vegas와 TCP Reno를 혼용하여 사용하는 경우 충분한 성능을 발휘하지 못하는 경우와 또한 RTT가 서로 다른 TCP Vegas간에 존재하는 공정성 문제가 있다. 본 논문에서는 이러한 불공정성 문제에 대해 TCP Vegas의 알고리즘의 주요 파라미터인 $\alpha$, $\beta$, $\gamma$�璲だ� 변화에 따라 TCP Reno와의 공정성 향상과 RTT가 서로 다른 TCP Vegas끼리의 공정성 문제를 분석하였다.

  • PDF

Late-term healing in an augmented sinus with different ratios of biphasic calcium phosphate: a pilot study using a rabbit sinus model

  • Lim, Hyun-Chang;Hong, Ji-Youn;Lee, Jung-Seok;Jung, Ui-Won;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.1
    • /
    • pp.57-69
    • /
    • 2016
  • Purpose: The aim of this pilot study was to determine the osteoconductivity and dimensional stability of augmented sinuses using different ratios of biphasic calcium phosphate (BCP) in a rabbit sinus model. Methods: Each sinus of New Zealand white rabbits (2.5-3.5 kg) was assigned to one of two groups: BCP with a hydroxyapatite to ${\beta}$-tricalcium phosphate (HA:${\beta}$-TCP) ratio of 70:30 (group TCP30) and BCP with an HA:${\beta}$-TCP ratio of 30:70 (group TCP70). After preparing a window in the antral wall of a sinus, the Schneiderian membrane was elevated, and the applicable material was grafted. A fluorochrome calcein green was injected five days before euthanizing the animals at four months post-surgery. The specimens were analyzed histologically, histomorphometrically, and by using micro-computed tomography (micro-CT). Results: Micro-CT analysis revealed that the total augmented volume and the new bone volume did not differ significantly between the two groups whereas the resorption of materials was greater in the TCP70 group. The trabecular thickness, number, and separation also did not differ significantly between the two groups. Histomorphometrically, the areas of total augmentation, new bone, and residual material, as well as the ratio of new-bone-material contact did not differ significantly between the groups. Histologically, the residual particles were more scattered in the TCP70 group than in the TCP30 group. The fluorescence of the calcein green did not differ notably between the two groups. Conclusions: The osteoconductivity and dimensional stability of the two BCPs with different ratios tested in this study were comparable after four months of healing. Therefore, we conclude that both BCPs show promise as a bone substitute for sinus augmentation.

Fabrication of Porous β-TCP Bone Graft Substitutes Using PMMA Powder and their Biocompatibility Study (PMMA를 이용한 다공질 β-TCP 골충진제 제조 및 생체적합성 평가)

  • Song, Ho-Yeon;Youn, Min-Ho;Kim, Young-Hee;Min, Young-Ki;Yang, Hun-Mo;Lee, Byong-Taek
    • Korean Journal of Materials Research
    • /
    • v.17 no.6
    • /
    • pp.318-322
    • /
    • 2007
  • Porous ${\beta}-tricalcium$ phosphate $({\beta}-TCP)$ bioceramic was fabricated by pressureless sintering using commercial HAp and different volume percentages of PMMA powders (30-60 vol.%). The range of spherical pore size was about $200-250\;{\mu}m$ in diameter. By increasing the PMMA content, the number of pores and their morphology were dramatically changed as well as decreased the material properties. In case of using 60 vol.% PMMA content, network-type pores were found, due to the necking of the PMMA powders. The values of relative density, elastic modulus, bending strength and hardness of the 60 vol.% PMMA content sample, sintered at $1500^{\circ}C$, were about 46%, 22.2 GPa, 5MPa and 182 Hv respectively. Human osteoblast-like MG-63 cells and osteoclast-like Raw 264.7 cells were well grown and fully covered all of the porous ${\beta}-TCP$ bodies sintered at $1500^{\circ}C$.

A simple chemical method for conversion of Turritella terebra sea snail into nanobioceramics

  • Sahin, Yesim Muge;Orman, Zeynep;Yucel, Sevil
    • Journal of Ceramic Processing Research
    • /
    • v.19 no.6
    • /
    • pp.492-498
    • /
    • 2018
  • In this study, a sea shell was converted into bioceramic phases at three different sintering temperatures ($450^{\circ}C$, $850^{\circ}C$, $1000^{\circ}C$). Among the obtained bioceramic phases, a valuable ${\beta}-TCP$ was produced via mechanochemical conversion method from sea snail Turritella terebra at $1000^{\circ}C$ sintering temperature. For this reason, only the bioceramic sintered at $1000^{\circ}C$ was concentrated on and FT-IR, SEM/EDX, BET, XRD, ICP-OES analyses were carried out for the complete characterization of ${\beta}-TCP$ phase. Biodegradation test in Tris-buffer solution, bioactivity tests in simulated body fluid (SBF) and cell studies were conducted. Bioactivity test results were promising and high rate of cell viability was observed in MTT assay after 24 hours and 7 days incubation. Results demonstrated that the produced ${\beta}-TCP$ bioceramic is qualified for further consideration and experimentation with its features of pore size and ability to support bone tissue growth and cell proliferation. This study suggests an easy, economic method of nanobioceramic production.

Randomized clinical trial on the efficacy of Escherichia coli-derived rhBMP-2 with ${\beta}$-TCP/HA in extraction socket

  • Huh, Jung-Bo;Lee, Hyo-Jung;Jang, Ji-Woong;Kim, Myung-Jin;Yun, Pil-Young;Kim, Su-Hong;Choi, Kyung-Hee;Kim, Young-Kyun;Cho, Kyoo-Sung;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.161-165
    • /
    • 2011
  • PURPOSE. This randomized clinical trial was conducted to assess the safety and effectiveness of the ErhBMP-2 in alveolar bone regeneration as well as preservation of the ${\beta}$-TCP bone graft material that contains ErhBMP-2. MATERIALS AND METHODS. This study involved 72 patients at the 3 study centers. The patients, who were divided into 2 groups: the experiment group who had ErhBMP-2 coated TCP/HA and the control group who had TCP/HA graft material alone transplanted immediately after tooth extraction. CT was taken before and 3 months after the transplantation and healing status was compared between the two groups. The efficacy endpoints that were used to measure the degree of bone induction included alveolar bone height and 3 measurements of bone width. The paired t test was used to determine the significance of the changes (P<.05). RESULTS. Changes in alveolar bone height were $-1.087{\pm}1.413$ mm in the control group and $-.059{\pm}0.960$ mm in the experimental group (P<.01). At 25% extraction socket length [ESL], the changes were $0.006{\pm}1.149$ mm in the control group and $1.279{\pm}1.387$ mm in the experimental group. At 50% ESL, the changes were $0.542{\pm}1.157$ mm and $1.239{\pm}1.249$ mm, respectively (P<.01 for 25% ESL, and P<.05 for 50% ESL). During the experiment, no adverse reactions to the graft material were observed. CONCLUSION. ErhBMP-2 coated ${\beta}$-TCP/HA were found to be more effective in preserving alveolar bone than conventional ${\beta}$-TCP/HA alloplastic bone graft materials.

The Effect of Electroacupuncture at the ST36 on the Electroencephalogram (족삼리(ST36) 전침 자극이 뇌파에 미치는 영향)

  • Gwon, Sun-Cheol;Youn, Dae-Sik;Lee, Sang-Ryong
    • Korean Journal of Acupuncture
    • /
    • v.23 no.1
    • /
    • pp.15-36
    • /
    • 2006
  • Objectives . The aim of this study was to examine the effect of electroacupuncture(EA) at the ST36 on normal humans by using power spectral analysis. Methods : EEG(Electroencephalogram) power spectral exhibits site-specific and state-related differences in specific frequency bands. In this study, power spectrum was used as a measure of complexity. 32 channel EEG study was carried out in 12 subjects (10 males; age=26.7 years old, 2females; age=28 years old). Results ; In ${\alpha}$ (alpha) band, the power values at Fp2, F7, F3, Fz, FTC1, FTC2, T3, C3, Cz, C4, TT1, TCP1, CP1, CP2,T5, P3, Pz, P4, Po1, Po2, O1, Oz,O2 channels(p<0.05) during the ST36-acupoint treatment were significantly increased. In ${\beta}$ (beta) band, the power values at Fp2, F7, F3, Fz, F4, F8, FTC1, FTC2, T3, C3, Cz, C4, TT1, TCP1, CP1, CP2, T5, P3, Pz, P4, Po1, Po2, O1, Oz, O2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. In ${\delta}$ (delta) band, the power values at F7, Fz, T3, C3, TT1, TCP1, CP1, CP2, T5, P3, Pz,T6, Po1, PO2,O1, Oz, O2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. In ${\theta}$(theta) band, the power values at F7, Fz, FTC1, T3, TCP1, CP2, TCP2, Po1, Po2 channels(p<0.05) during the ST36-acupoint treatment were significantly decreased. ${\alpha}$/${\beta}$ values at Cz, T5, O1, Oz, O2 channels during the ST36-acupoint treatment were increased. ${\beta}$/${\theta}$ values at Fpl, F7, F3, Fz, F4, F8, FTC1, FTC2, T3, C3, C4, T4, TT1, TCP1, TCP2, TT2, P3, P4, T6, Pol channels during the ST36-acupoint treatment were increased. Conclusions : This results suggest that Electroacupuncture at the ST36 mostly affects the charge on alpha(23 channels), beta(25 channels) bands.

  • PDF

Effect of Storage Conditions on the Setting Properties of Brushite Bone Cement Containing Granular β-Tricalcium Phosphate (과립형 β-삼인산칼슘을 사용한 Brushite계 골시멘트의 보관 조건에 따른 경화 특성)

  • Lee, Sun-Ae;Chung, Tai-Joo;Oh, Kyung-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.10
    • /
    • pp.625-630
    • /
    • 2008
  • In the bone cement composed of dense granules of $\beta-Ca_3(PO_4){_2}(\beta-TCP)$ and $Ca(H_2PO_4){_2}H_2O$, the compressive strength, setting time and temperature rise were measured to observe the degradation of cement with respect to the stored days before setting. Decreases of compressive strength and temperature rise were observed, while setting time increased with respect to the stored days. The similar trends were repeated with the increase of temperature of storage. Such a change virtually meant the fading of the character of cement and it took place only when the two starting materials were mixed during storage. The degradation could be mitigated taking advantage of granular $\beta$-TCP instead of powdery one. The formation of $CaHPO_4$, which resulted from reaction with ambient humidity, was attributed to the degradation observed during storage. Dependence of the degradation behavior on mixing and temperature during storage was discussed in terms of the driving force for reaction of cement.

Setting Behavior and Drug Release from Brushite Bone Cement prepared with Granulated Hydroxyapatite and β-Tricalcium Phosphate

  • Son, Yeong-Jun;Lee, In-Cheol;Jo, Hyun-Ho;Chung, Tai-Joo;Oh, Kyung-Sik
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.1
    • /
    • pp.56-64
    • /
    • 2019
  • Calcium phosphate bone cement was prepared to contain antibiotics for release after setting using granulated ${\beta}$-tricalcium phosphate (${\beta}$-TCP) and hydroxyapatite (HA). Gentamicin sulfate (GS) solution was infiltrated within the interconnected pores of the granule to avoid affecting the setting reaction and for protection of GS during the setting. Consequently, the setting time and the temperature increase were not affected, regardless of the loading of GS. The release of the GS from the cement was estimated by measuring the concentration at regular intervals from the cement dipped solution. The ${\beta}$-TCP granule loaded with GS exhibited the saturation of accumulative concentration at 16 h. In contrast, the HA granule with GS exhibited steady increase in accumulative concentration of over $10{\mu}g/ml$ at 144 h. Thus, the granulated cement could release the GS greater than the minimum inhibitory concentration of staphylococcus during the prescription peroid of the oral antibiotics.