Experimental study of bubble behaviors and CHF on printed circuit board (PCB) in saturated pool water at various inclination angles

  • Tanjung, Elvira F.;Alunda, Bernard O.;Lee, Yong Joong;Jo, Daeseong
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1068-1078
    • /
    • 2018
  • Experiments were performed to investigate bubble behaviors and pool boiling Critical Heat Flux (CHF) on a thin flat rectangular copper heater fabricated on Printed Circuit Board (PCB), at various inclination angles. The surface inclination angles were $0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, and $180^{\circ}$. Results showed the Onset of Nucleate Boiling (ONB) heat flux increased with increasing heater orientation from $0^{\circ}$ to $90^{\circ}$, while early ONB occurred when the heater faced downwards ($135^{\circ}$ and $180^{\circ}$). The nucleate boiling was observed to be unstable at low heat flux (1-21% of CHF) and changed into typical boiling when the heat flux was above 21% of CHF. The result shows the CHF decreased with increasing heater orientation from $0^{\circ}$ to $180^{\circ}$. In addition, the bubble departure diameter at the heater facing upwards ($0^{\circ}$, $45^{\circ}$, and $90^{\circ}$) was more prominent compared to that of the heater facing downward ($135^{\circ}$). The nucleation site density also observed increased with increasing heat flux. Moreover, the departed bubbles with larger size were observed to require a longer time to re-heat and activate new nucleation sites. These results proved that the ONB, CHF, and bubble dynamics were strongly dependent on the heater surface orientation.

Hemicellulose Recovery from Lignocellulosic Material Hydrolyzed by Water (물로 가수분해된 섬유성 기질로부터 hemicellulose 회수)

  • Kim, Sung-Bae;Kim, Chang, Joon
    • KSBB Journal
    • /
    • v.20 no.4
    • /
    • pp.317-322
    • /
    • 2005
  • Various recovery methods were investigated to maximize hemicellulose recovery from lignocellulosic material hydrolyzed by pure water. The pretreatment conditions of water hydrolysis were $170\~180^{\circ}C$ and 1 hour of reaction time. The percentage of hemicellulose solubilized increased as the temperature increased from 170 to $180^{\circ}C$. However, significant decomposition of sugar was observed at temperature of $180^{\circ}C$. From the results of water hydrolysis, the total amount of glucan in solid residue and liquid hydrolyzate was close to the total glucan in the original biomass. For hemicellulose, however, there was a significant difference between both contents. To prove this difference, various recovery methods were proposed. From the total sugar accountability (sugar in liquid + sugar in solid), it was confirmed that hemicellulose recovery in the hydrolyzate was increased if the product including both hydrolyzate and solid residue was physically stimulated by such as heating and ultrasound irradiation. This indicated that, in commercial scale processes that much bigger substrate sizes are used and a sufficient amount of leaching solvent can not be used after pretreatment, a significant amount of oligomers could be trapped in the solid matrix.

Fabrication and transcription estimation of prismless LGP for cellular phone using E-Mold technology (전열가열방식을 이용한 휴대전화용 복합기능 도광판 제작 및 전사성 평가)

  • Kim, Young-Kyun;Chung, Jae-Youp;Kim, Dong-Hak
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.186-193
    • /
    • 2009
  • In this paper, we adopted E-MOLD patent technology in order to fabricate Prismless LGP(Light Guide Panel) fur cellular phone and estimate the transcription of injection-molded parts. Then, we manufactured the Ni stamper fur Prismless LGP using MEMS process. And the stamper was installed in the movable heated core which is the key part of a patented mold. Using this mold, we manufactured injection-molded plastic LGP parts with different mold temperatures so that we investigate effect of the temperature on the transcription of the parts. The CAE analysis was also conducted in order to compare with the experimental results. The transcription of LGP parts with various mold temperature displayed $100^{\circ}C$(25.0nm), $140^{\circ}C$(48.4nm), $180^{\circ}C$(52.1nm) and when compared with stamper(521Inm), transcription was superior at $180^{\circ}C$. According to the CAE results, moldability was improved as mold temperature ($50^{\circ}C{\sim}180^{\circ}C$) increased, but when filling time($1{\sim}2sec$) increases, it decreased at $160^{\circ}C$. And transcription and moldability were improved markedly at glass transition temperature($140^{\circ}C$).

The Study of Isokinetic Exercise Test of Trunk Rotation of 20's Male College Students (20대 남자대학생의 몸통회전에 대한 등속성운동 검사에 관한 연구)

  • Choi, Byung-Ok
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.2
    • /
    • pp.21-25
    • /
    • 2006
  • Objective: The purposes of this study are to provide fundamental data and a rehabilitation program in physical therapy. It has been operated by 30 male college students for lumbar isokinetic exercises. Method : Subjects have been carried out in an experiment by Biodex system operating isokinetic torso rotation. This performance was activated by left rotation after right rotation repeatedly. Results: 1. The mean peak torques at $60^{\circ}$/sec were $95.6{\pm}20.62$ (Rt) and $93.84{\pm}18.41$ (Lt). 2. The mean peak torques/body weight at $60^{\circ}$/sec were $69.28{\pm}28.31$ (Rt) and $67.07{\pm}27.04$ (Lt). 3. The total works in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $492.21{\pm}92.37$, $1294.97{\pm}278.96$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $515.78{\pm}109.47$, $1443.74{\pm}329.67$. 4. The work to body weight ratio at $60^{\circ}$/sec was $78.30{\pm}32.37$ (Rt) and $79.93{\pm}37.30$ (Lt). 5. The average powers in right side at $60^{\circ}$/sec and $180^{\circ}$/sec were $76.75{\pm}16.69$, $117.19{\pm}29.94$ and in left side at $60^{\circ}$/sec and $180^{\circ}$/sec were $78.54{\pm}18.58$, $125.39{\pm}32.90$. 6. The work fatigue at $180^{\circ}$/sec was $21.76{\pm}14.82$ (Rt) and $19.66{\pm}26.23$ (Lt). Conclusion: In right side and left side, there was no significant difference in peak torque. peak torque/body weight, work to body-weight ratio, average power of trunk rotators at $60^{\circ}$/sec(p<0.05). However there was a significant difference in the total work of trunk rotators at $60^{\circ}$/sec(p>0.05). Also there was a significant difference in the average of trunk rotators at $180^{\circ}$/sec(p>0.05).

  • PDF

A Study on Aerodynamic Damping and Aeroelastic Instability of Helical-shaped Super Tall Building (나선형 초고층건물의 공력불안정 진동과 공력감쇠에 관한 연구)

  • Kim, Wonsul;Yoshida, Akihito;Tamura, Yukio;Yi, Jin-Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.1
    • /
    • pp.95-103
    • /
    • 2016
  • In this paper, aeroelastic instability and aerodynamic damping ratio of a helical $180^{\circ}$ model which shows better aerodynamic behavior in both along-wind and crosswind responses on a super tall building was investigated by an aeroelastic model test, and the aerodynamic damping ratio was evaluated from the wind-induced responses of the model by using Random Decrement Technique. Aerodynamic damping ratios evaluated in this study were verified through comparison with previous results obtained by quasi-steady theory. As a result, the aeroelastic instability of the helical $180^{\circ}$ model in crosswind direction were not occurred for any conditions with increasing the reduced wind velocity while the square model generally encounters aeroinstability due to the vortex shedding. The aerodynamic damping in along-wind direction for the helical $180^{\circ}$ and the square model increased monotonically both with reduced wind velocity, i.e., there is no relation with modifications of building shapes. On the other hand, in crosswind direction, the characteristics of aerodynamic damping ratio with reduced wind velocity for helical $180^{\circ}$ model were quit different from those of the square model.

Numerical computation of turbulent flow in a square sectioned $180^{\circ}$ bend by low-Reynolds-number second moment turbulence closure (저레이놀즈수 2차 모멘트 난류모형에 의한 정사각단면의 $180^{\circ}$ 곡덕트 난류유동의 수치해석)

  • Sin, Jong-Geun;Choe, Yeong-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.8
    • /
    • pp.2650-2669
    • /
    • 1996
  • A new low Reynolds number nonlinear second moment turbulence closure was introduced to analyze a square sectioned 180.deg. bend flow. Inclusion of nonlinear return to isotropy term and cubic mean pressure strain term has brought out a marked improvement in the level of agreement with measured velocity profiles. Optimization of present closure was performed by comparison of computed velocity profiles with the experimental ones with variation of nonlinear return to isotropy term and quadratic and cubic pressure-strain model. Progressive vortex breakdown due to the interaction of primary and secondary flows was well captured by using the optimized second moment turbulence closure.

Analysis of Turbulent Flow in a Square Duct with a $180^{\circ}$ Bend ($180^{\circ}$곡관을 갖는 정사각 단면 덕트에서의 란류류동 해석)

  • Launder, B. E.;Kim, Myung-Ho;Moon, Chan;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.607-621
    • /
    • 1988
  • The paper describes the incorporation of an algebraic stress model(ASM) of turbulence in to a semi-elliptic solution procedure for the prediction of turbulent flow in passage around a 180.deg. square sectioned bend. The numerical results are obtained from a finite-volume discretization with applications of QUICK scheme and full find grid system without PSL approximation. Results show that the better agreements in velocity profiles with experimental data than those from k, $\varepsilon$ equation model with wall function and PSL are obtained. Predictions of Reynolds stresses also show good agreements with the experimental data.

Influence of Velocity on Pressure Drop of Flowing Ice Slurry in Elbow and its continued Inclined Tube (곡관과 연속된 경사관 내에서 유동하는 아이스슬러리의 압력손실에 미치는 유속의 영향)

  • Park Ki-Won;Kim Kyu-Mok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.635-641
    • /
    • 2005
  • This study experimented to understand the effects of transporting ice slurry through elbow and inclined tube. And at this experiment it used propylene glycol-water solution and a diameter of about 2mm ice particle. The experiments were carried out under various conditions, with velocity of water solution at the entry ranging from 1.0 to 3.5 w/s and elbows and inclined tubes of 4 kinds angle with $30^{\circ},\;45^{\circ},\;90^{\circ}\;and\;180^{\circ}$. The pressure drop between the tube entry and exit were measured. According to angle of bending, the highest pressure drop was measured at $30^{\circ}$ elbow and the lowest pressure drop was measured at $90^{\circ}$ elbow, and there are only a little differences of pressure drop between $45^{\circ}$ elbow and $180^{\circ}$ elbow. According to angle of inclined tube, the highest pressure drop was measured at $90^{\circ}$ inclined tube and the pressure drop at $45^{\circ},\;30^{\circ},\;180^{\circ}$ inclined tubes were lower successively. The lowest pressure drop in elbows and inclined tubes was measured at velocity of $2.0\~2.5$ m/s and concentration of $10\;wt\%$.

Heat Transfer and Pressure Drop Characteristics in Zigzag Channel Angles of Printed Circuit Heat Exchangers (지그재그채널 PCHE의 각도에 따른 열전달 및 압력강하특성)

  • Choi, Mi-Jin;Kwon, Oh-Kyung;Cha, Dong-An;Yeun, Jae-Ho
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1147-1152
    • /
    • 2009
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the zigzag channel PCHE using diffusion bonding technology by numerical analysis. PCHE of five types are designed, which are zigzag channel angle $180^{\circ}$, $160^{\circ}$, $140^{\circ}$, $120^{\circ}$ and $100^{\circ}$. The zigzag PCHE was numerically investigated for Reynolds number in a range of $150{\sim}800$. The temperatures of the hot side were performed at $80^{\circ}C$ while that of the cold side was conducted at $20^{\circ}C$. The results show that the performance of heat transfer rate for zigzag channel $100^{\circ}$ increases about 11.5% compared to that of zigzag channel $180^{\circ}$. On the other hand, the performance of pressure drop for zigzag channel $100^{\circ}$ is remarkably higher than that of zigzag channel $180^{\circ}$, about 1.4 times.

  • PDF

Heat Transfer and Pressure Drop Characteristics in Zigzag Channel Angles of Printed Circuit Heat Exchangers (지그재그채널 PCHE의 각도에 따른 열전달 및 압력강하특성)

  • Kwon, Oh-Kyung;Choi, Mi-Jin;Choi, Young-Jong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.475-482
    • /
    • 2009
  • The objectives of this paper are to study the characteristics of heat transfer and pressure drop of the zigzag channel PCHE using diffusion bonding technology by numerical analysis. PCHE of five types are designed, which are zigzag channel angle 180$^{\circ}$, 160$^{\circ}$, 140$^{\circ}$, 120$^{\circ}$ and 100$^{\circ}$. The zigzag PCHE was numerically investigated for Reynolds number in a range of 150$\sim$800. The temperatures of the hot side were performed at 80$^{\circ}$ while that of the cold side was conducted at 20$^{\circ}C$. The results show that the performance of heat transfer rate for zigzag channel 100$^{\circ}$ increases about 11.5% compared to that of zigzag channel 180$^{\circ}$. On the other hand, the performance of pressure drop for zigzag channel 100$^{\circ}$ is remarkably higher than that of zigzag channel 180$^{\circ}$, about 2.4 times.