• Title/Summary/Keyword: $[^{201}Tl]$

Search Result 91, Processing Time 0.033 seconds

Prediction of Salvaged Myocardium in Patients with Acute Myocardial Infarction after Primary Percutaneous Coronary Angioplasty using early Thallium-201 Redistribution Myocardial Perfusion Imaging (급성심근경색증의 일차적 관동맥성형술 후 조기 Tl-201 재분포영상을 이용한 구조심근 예측)

  • Choi, Joon-Young;Yang, You-Jung;Choi, Seung-Jin;Yeo, Jeong-Seok;Park, Seong-Wook;Song, Jae-Kwan;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.219-228
    • /
    • 2003
  • Purpose: The amount of salvaged myocardium is an important prognostic factor in patients with acute myocardial infarction (MI). We investigated if early Tl-201 SPECT imaging could be used to predict the salvaged myocardium and functional recovery in acute MI after primary PTCA. Materials and Methods: In 36 patients with first acute MI treated with primary PTCA, serial echocardiography and Tl-201 SPECT imaging ($5.8{\pm}2.1$ days after PTDA) were performed. Regional wall motion and perfusion were quantified with on 16-segment myocardial model with 5-point and 4-point scaling system, respectively. Results: Wall motion was improved in 78 of the 212 dyssynergic segments on 1 month follow-up echocardiography and 97 on 7 months follow-up echocardiography, which were proved to be salvaged myocardium. The areas under receiver operating characteristic curves of Tl-201 perfusion score for detecting salvaged myocardial segments were 0.79 for 1 month follow-up and 0.83 for 7 months follow-up. The sensitivity and specificity of Tl-201 redistribution images with optimum cutoff of 40% of peak thallium activity for detecting salvaged myocardium were 84.6% and 55.2% for 1 month follow-up, and 87.6% and 64.3% for 7 months follow-up, respectively. There was a linear relationship between the percentage of peak thallium activity on early redistribution imaging and the likelihood of segmental functional improvement 7 months after reperfusion. Conclusion: Tl-201 myocardial perfusion SPECT imaging performed early within 10 days after reperfusion can be used to predict the salvaged myocardium and functional recovery with high sensitivity during the 7 months following primary PTCA in patients with acute MI.

Accuracy Evaluation of CT-Based Attenuation Correction in SPECT with Different Energy of Radioisotopes (SPECT/CT에서 CT를 기반으로 한 Attenuation Correction의 정확도 평가)

  • Kim, Seung Jeong;Kim, Jae Il;Kim, Jung Soo;Kim, Tae Yeop;Kim, Soo Mee;Woo, Jae Ryong;Lee, Jae Sung;Kim, Yoo Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 2013
  • Purpose: In this study, we evaluated the accuracy of CT-based attenuation correction (AC) under the conventional CT protocol (140 kVp, on average 50-60 keV) by comparing the SPECT image qualities of different energy of radioisotopes, $^{201}Tl,\;^{99m}Tc$ and $^{131}I$. Materials and Methods: Using a cylindrical phantom, three different SPECT scans of $^{201}Tl$ (70 keV, 55.5 MBq), $^{99m}Tc$ (140 keV, 281.2 MBq) and $^{131}I$ (364 keV, 96.2 MBq) were performed. The CT image was obtained with 140 kVp and 2.5 mA in GE Hawkeye 4. The OSEM reconstruction algorithm was performed with 2 iterations and 10 subsets. The experiments were performed in the 4 different conditions; non-AC and non-scatter correction (SC), only AC, only SC, AC and SC in terms of uniformity and center to peripheral ratio (CPR). Results: The uniformity was calculated from the uniform whole region in the reconstructed images. For $^{201}Tl$ and $^{99m}Tc$, the uniformities were improved by about 10-20% AC was applied, but these were decreased by about 2% as SC was applied. The uniformity of $^{131}I$ was slightly increased as both AC and SC were applied. The CPR of the reconstructed image was close to one, when AC was applied for $^{201}Tl$ and $^{99m}Tc$ scans and $^{131}I$ was distant from 1 and that is only AC. Conclusion: The image uniformity improved by AC on low energy likely to $^{201}Tl$ and $^{99m}Tc$. However, image uniformity of high energy such as $^{131}I$ was improved, when both AC and SC was applied.

  • PDF

Clinical Study of Simultaneous Acquisition Rest 99mTc-sestaMIBI/Stress 201Tl Dual-Isotope Myocardial Perfusion Imaging with a Solid-State Dedicated Cardiac Gamma Camera (반도체 심근 전용 감마카메라를 이용한 Rest 99mTc-sestaMIBI/Stress201Tl 이중 동위원소 심근 관류 동시 스캔에 관한 임상적 고찰)

  • Bahn, Young-Kag;Kim, Dong-Heui;Choi, Yong-Hoon;Kang, Chun-Koo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.88-91
    • /
    • 2018
  • Purpose The purpose of this study is to investigate the simultaneous dual isotope (SDI) myocardial perfusion scan that can be performed in a short time using a semiconductor gamma camera. Materials and Methods Of the 86 patients who underwent Rest/Stress $^{99m}TC$-sestaMIBI 1-day myocardial perfusion scan and Rest $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope myocardial perfusion scan using a heart-only gamma camera, the test results were the same, 36 patients who did not show any change in the clinical outcome. Quantitative values were statistically analyzed using a QPS program to confirm the correlation between the images of the two examinations. Results Rest/Stress $^{99m}TC$-sestaMIBI simultaneous dual myocardial perfusion scans and $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ double-isotope myocardial perfusion scans were analyzed for Summed score. The $R^2$ value of the Rest summed score (RSS) was 0.91 and the $R^2$ value of the stress summed score (SSS) was 0.71. Conclusion The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan confirmed its correlation with the previous day's test. The $^{99m}TC$-sestaMIBI/Stress $^{201}Tl$ simultaneous dual isotope scan can be completed in approximately 30minutes. It maybe clinically useful for patients who need short examination time such as emergency patients or elderly patients.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Dipyridamole Induced Transient Left Ventricular Dysfunction in the Tl-201 Gated Myocardial SPECT (Tl-201 게이트 심근 SPECT에서 디피리다몰 부하로 유도된 일시적 좌심실 기능이상)

  • Won, Kyoung-Sook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.153-161
    • /
    • 2003
  • Purpose: Recently the occurrence of dipyridamole stress-induced short term stunning was proven and it is reported that Bland Altman analysis by repeated acquisition Tl-201 gated myocardial SPECT (gSPECT) revealed the 95% limit of agreement for LVEF was 10.3 %. The purpose of this study was to investigate the clinical value of dipyridamole induced transient LV dysfunction on Tl-201 gSPECT. Materials and Methods: Total 93 patients were included and coronary angiography was peformed in all patients less than 2 month from gSPECT. The patients with myocardial infarction were excluded. All patients underwent both dipyridamole stress and 4-h redistribution Tl-201 gSPECT. Forty nine patients of total 93 showed normal coronary arteries (Group 1) and the remaining 44 patients had coronary artery disease (Group 2). We compared LV EF, EDV and ESV during post-stress and 4-h redistribution period calculated by gSPECT using quantitative gated SPECT software and the incidence of dipyridamole induced transient LV dysfunction between group 1 and 2. The criteria for transient LV dysfunction was defined more decrease ${\geq}11%$ of LVEF during post-stress than 4-h redistribution according to previous reported Bland Altman analysis. Results: During post-stress and 4-h redistribution average of 3.1% increment in LVEF, 6.6% increment in LVEDV and 0.7% decrement in LVESV were shown after stress in Group 1, whereas 4.1% decrement, 9.7% increment and 7.2% increment in Group 2 respectively. Dipyridamole induced transient LV dysfunction was only detected in group 2 (18.2%) and not in group 1. It was more frequently observed in triple vessel disease and left main disease (31.8%, N=22) than one and two vessel disease (4.5%, N=22). Conclusion: As with Tc-99m myocardial agent post-stress LV dysfunction was observed in dipyridamole Tl-201 gSPECT. It was only detected in CAD and more frequently occurred in multivessel disease. Thus this finding seems to provide additional information in the diagnosis of coronary artery disease and prediction of prognosis.

Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$ ($^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교-)

  • Bom, Hee-Seung;Kim, Ji-Yeul;Park, Joo-Hyung;Ahn, Young-Keun;Jeong, Myung-Ho;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF

Dual-Isotope SPECT Imaging with Thallium-201 and Technetium-99m MIBI in Detecting Coronary Artery Disease (관상동맥질환 진단에서 Thallium-201과 Technetium-99m MIBI를 이용한 Dual-Isotope SPECT 영상)

  • Lee, Gyu-Gwang;Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.1
    • /
    • pp.101-107
    • /
    • 1999
  • We evaluated the results of sequential SPECT dual-isotope imaging with Tl-201 and Tc-99m MIBI in 24 patients. all of whom also had coronary angiography within the past one month. Coronary angiography showed that 12 patients had no CAD, 4 patients had one-vessel CAD, 7 patients had two-vessel CAD and 1 patient had three-vessel CAD. Serial studies of resting Tl-201 and dipyridamole stress Tc-99m MIBI were completed within 2 hours. When more than 50% of coronary artery narrowing was considered significant, the overall sensitivity and specificity of CAD detection were 91.7%. The sensitivity of CAD detection in patients with one-vessel and multi-vessel diseases was 75% and 100%. respectively. Therefore, sequential dual-isotope SPECT demonstrated high sensitivity and specificity for CAD detection. In conclusion, sequential dual-isotope imaging is feasible and can be completed in a short time and may therefore enhance laboratory throughput and patient convenience.

  • PDF

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF