Fig. 1. Air quality system schematic
Fig. 2. Air quality system artwork (Up-Front, Down-Back)
Fig. 3. Air quaility system schematic(Power part)
Fig. 4. Sensor schematic(CO&NOx, NH3 Part)
Fig. 5. Sensor schematic(CO2 Part)
Fig. 6. Sensor schematic(VOCs Part)
Fig. 7. Air quality system proto sample ass’y
Fig. 8. AQS in gas measurement chamber
Fig. 9. Environment of gas measurement system
Fig. 10. Dry and wet fuel(leaves, etc.)
Fig. 11. Indoor gas measurement
Fig. 12. Indoor gas measurement data
Fig. 13. Installation of AQS on the vehicle
Fig. 14. Smoke difference before and after a fire
Fig. 15. Outdoor gas measurement data
Fig. 16. Spiral driving for gas assessment
Fig. 17. Results of spiral driving test
Table 1. Various gas sensor for measurement.
References
- B. M. Wotton, D. L. Martell, K A. Logan "Climate Change and People-Caused Forest Fire Occurrence in Ontario", Climatic Change, Vol.60, Issue.3, pp.275- 295, October, 2003. DOI: https://doi.org/10.1023/A:1026075919710
- B. J. Stocks, M. A. Fosberg, T. J. Lynham, L. Mearns, B. M. Wotton, Q. Yang, J-Z. Jin, K. Lawrence, G. R. Hartley, J. A. Mason, D. W. McKENNEY, "Climate Change and Forest Fire Potential in Russian and Canadian Boreal Forests", Climatic Change, Vol.38, Issue.1, pp.1-13, January, 1998. DOI: https://doi.org/10.1023/A:1005306001055
- G. Wotawa1, M. Trainer, "The Influence of Canadian Forest Fires on Pollutant Concentrations in the United States", American Association for the Advancement of Science, Vol.288, No.5464, pp.324-328, April, 2000. DOI: 10.1126/science.288.5464.324
- R. G. Gann, V. Babrauskas, R. D. Peacock, J. R. Hall Jr, "Fire conditions for smoke toxicity measurement", Fire and Materials, Vol.18, No. 3, pp. 193-199, June, 1994. DOI: https://doi.org/10.1002/fam.810180306
- W. R. Cofer III, E. L. Winstead, B. J. Stocks, J. G. Goldammer, D. R. Cahoon, "Crown fire emissions of CO2, CO, H2, CH4, and TNMHC from a dense Jack pine boreal forest fire", Geophysical Research Letters, Vol.25, No.21, pp. 3919-3922, November, 1998. https://doi.org/10.1029/1998GL900042
- D. Gutmacher, C. Foelmlib, W. Vollenweiderb, U. Hoeferb, J. Wollensteina, "Comparison of gas sensor technologies for fire gas detection", Procedia Engineering, Vol.25, pp.1121-1124, January, 2012. DOI: https://doi.org/10.1016/j.proeng.2011.12.276
- D. Gutmacher, U. Hoefer, J. Wollenstein, "Gas sensor technologies for fire detection", Sensors and Actuators B: Chemical, Vol.175, pp.40-45, December, 2012. DOI: https://doi.org/10.1016/j.snb.2011.11.053
- J. Kesselmeier, U. Kuhn, S. Rottenberger, T. Biesenthal, A. Wolf,1 G. Schebeske, M. O. Andreae, P. Ciccioli, E. Brancaleoni, M. Frattoni, S. T. Oliva, M. L. Botelho, C. M. A. Silva, and T. M. Tavares, "Concentrations and species composition of atmospheric volatile organic compounds (VOCs) as observed during the wet and dry season in Rondonia", Journal of Geophysical and Research, Vol.107, Issue.D20, pp. LBA 20-1-LBA 20-13, September, 2002. DOI: https://doi.org/10.1029/2000JD000267
- E. S. Kim, D. H. Kim, J. H. Kim "A Study on the Characteristics of Combustion according to the Type of Forest Fire", Fire Research Report, pp.185-229, 2010. DOI: https://doi.org/10.7467/KSAE.2012.20.1.068