DOI QR코드

DOI QR Code

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse

강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향

  • Jeong, Young Kyun (Dept. of Agricultural Eng., Gyeongsang National Univ.(Institute of Agriculture and Life Science, GNU)) ;
  • Lee, Jong Goo (Dept. of Agricultural Eng., Gyeongsang National Univ.(Institute of Agriculture and Life Science, GNU)) ;
  • Yun, Sung Wook (Dept. of Agricultural Engineering, National Academy of Agricultural Science, RDA) ;
  • Kim, Hyeon Tae (Dept. of Bio-Industrial Machinery Eng.. Gyeongsang National Univ.(Institute of Agriculture & Life Science)) ;
  • Ahn, Enu Ki (UBN Corporation) ;
  • Seo, Jae Seok (UBN Corporation) ;
  • Yoon, Yong Cheol (Dept. of Agricultural Eng., Gyeongsang National Univ.(Institute of Agriculture and Life Science, GNU))
  • 정영균 (경상대학교 지역환경기반공학과(농업생명과학연구원)) ;
  • 이종구 (경상대학교 지역환경기반공학과(농업생명과학연구원)) ;
  • 윤성욱 (국립원예 특작 과학원 시설원예 연구소) ;
  • 김현태 (경상대학교 생물산업기계공학과(농업생명과학연구원)) ;
  • 안은기 ((주)유비엔) ;
  • 서재석 ((주)유비엔) ;
  • 윤용철 (경상대학교 지역환경기반공학과(농업생명과학연구원))
  • Received : 2019.01.17
  • Accepted : 2019.01.28
  • Published : 2019.01.31

Abstract

This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.

본 연구에서는 본 연구실에서 자체적으로 제작한 비교적 제작이 간편하고 비용이 저렴한 강제 흡출식 복사선차폐장치(Aspirated Radiation Shield; ARS)로 측정한 실측 데이터를 바탕으로 장치의 성능과 온도 및 상대습도의 측정오차에 대하여 보고하고자 연구를 수행하였다. 그 결과를 요약하면 다음과 같다. ARS장치와 진주기상대에서 측정한 최대, 평균 및 최저온도의 범위는 각각 $2.0{\sim}34.1^{\circ}C$$0.4{\sim}31.5^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$$-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$$-14.0{\sim}15.1^{\circ}C$범위로 나타났다. 최대기온의 최저 및 최고온도에서 각각 $1.6^{\circ}C$$2.6^{\circ}C$정도 교내에서 측정한 값이 약간 높게 나타난 것을 제외하면, 두 기관에서 측정한 온도에 큰 차이가 없는 것을 알 수 있었다. 표준온도계의 측정값과 검증한 결과, ARS장치로 측정한 온도가 표준온도계에 비해 $-2.0^{\circ}C$정도 낮거나 $1.8^{\circ}C$보다 높게 나타나났다. 표준온도계와 상관분석 한 결과, 결정계수는 0.99정도였다. 팬의 유무에 따른 온도의 경우, 전체적으로 팬이 없는 경우가 최고, 평균 및 최저온도가 각각 $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$$0.5{\sim}3.9^{\circ}C$정도 높게 나타났다. 그리고 ARS장치와 진주기상대에서 측정한 일평균 상대습도는 전체적으로 ARS장치로 측정한 값이 약간 높은 경향이 있고, 특히 상대적으로 6월 27일, 7월 26일, 29일, 8월 20일에 측정한 값이 각각 5.7%, 5.2%, 9.1% 및 5.8%정도로 다소 높게 나타났지만, 두 기관의 월별 평균치는 2.0~3.0%정도로 미미한 수준이었다. 또한 ARS장치와 아스만 통풍습도계로 측정한 상대습도는 전체적으로 -3.98~+7.78%정도의 범위 내에 있는 것으로 나타났다. 진주기상대와 아스만 통풍습도계로 측정한 상대습도를 상관분석 결과, 결정계수가 각각 0.94 및 0.97정도로써 높은 상관관계를 보였다.

Keywords

References

  1. Erell, E., V. Leal, and E. Maldonado. 2005. Measurement of air temperature in the presence of a large radiant fiux: An assessment of passively ventilated thermometer screen. Boundary-Layer Meteorol 134: 181-193. https://doi.org/10.1007/s10546-009-9430-2
  2. Kurzeja, R. 2010. Accurate temperature measurements in a naturally-aspirated radiation shield. Boundary-Layer Meteorol 134: 181-193. https://doi.org/10.1007/s10546-009-9430-2
  3. Konno, S. and H. Takahashi. 2012. Comparison of temperatures measured by using a natural ventilation radiation shield and an aspirated ventilation radiation shield of AMeDAS ststion. Geographical reports of Tokyo Metropolitan University. 47:39-49.
  4. Kwon, S. J., Y. B. Min, J. S. Choi, and Y. C. Yoon. 2012. Performance analysis of photovoltaic system for greenhouse. J. Agric. & Life Sci. 46: 141-150 (in Korean).
  5. Nakamura, R. and L. Mahrt. 2005. Air temperature measurement error in naturally aspirated radiation shields. Journal of Atmospheric and Oceanic Technology. 22: 1046-0518. https://doi.org/10.1175/JTECH1762.1
  6. Mahajan, R.L., B.M. Fichera, and T.W. Horst. 2005. Mechanically aspirated radiation shields: A CFD and neural netwok design analysis. International Journal of Heat and Mass Transfer. 48:2856-2867. https://doi.org/10.1016/j.ijheatmasstransfer.2005.01.026
  7. Ministry of Agriculture, Food and Rural Affairs(MAFRA). 2018a. Greenhouse status for the vegetable grown in facilities and the vegetable productions in 2017. Press release. 2018. http//www.marfa.go.kr (in Korean).
  8. Ministry of Agriculture, Food and Rural Affairs(MAFRA). 2017b. Cultivation status of floricultural crop in 2017. Press release. 2018. http//www.marfa.go.kr (in Korean).
  9. Richardson, S.J., F.V. Brock, S.R. Semmer and C. Jirak. 1999. Minimizing errors associated with multiplate radiation shields. Journal of Atmospheric and Oceanic Technology. 16: 1862-1872. https://doi.org/10.1175/1520-0426(1999)016<1862:MEAWMR>2.0.CO;2
  10. Roh, G.K. and W.M. Suh. 1998. Computerized environmental control in greenhouse. ed. The Korean Society for Hightech Agricultural Facilities. Korea. p.140. (in Korean).
  11. Suh, W.M. 1986. Modeling of a greenhouse equipped with a solar rockbed system and with carbon dioxide enrichment. Ph.D. Diss., Manhattan: Kansas State Univ., Manhattan, Kansas. p. 138-149.
  12. Thomas, C.K. and A.R Smooth. 2013. An effective, economic aspirated radiation shield for air temperature observation and its spatial gradients. Journal of Atmospheric and Oceanic Technology. 30: 526-537. https://doi.org/10.1175/JTECH-D-12-00044.1
  13. http//www.me.go.kr/home/web/index.do?menuld=64
  14. Yang, J., Q. Liu,, W. Dai, and R. Ding. 2017. Fluid dynamic analysis and experimental study of a low radiation error temperature sensor. Physics Letters A. 381: 177-183. https://doi.org/10.1016/j.physleta.2016.11.020
  15. Yang, J., Q. Liu,, W. Dai, and R. Ding. 2016. A temperature error correction method a naturally ventilated radiation shield. Journal of Atmospheric and Solar-Terrestrial Physics. 149: 40-45. https://doi.org/10.1016/j.jastp.2016.09.010
  16. Yang, S.H., C.G Lee, J.Y. Kim, W.K. Lee, A.A Araghi, and J.Y. Rhee. 2012. Effects of fan-aspirated radiation shield for temperature measurement in greenhouse environment. J. of Biosystems Eng. 37: 245-251 (in Korean). https://doi.org/10.5307/JBE.2012.37.4.245
  17. Yoon, Y. C., Y. S. Shin, H. T. Kim, S. B. Bae, J. S. Choi, and W. M. Suh. 2012a. Heating performance of hot water supplying system in greenhouse. J. Bio-Env. Cont. 21: 79-87 (in Korean).
  18. Yoon, Y. C., Y. S. Shin, S. B. Bae, H. T. Kim, J. S. Choi, and W.M. Suh. 2012b. Variation of indoor air temperature by using hot water piping in greenhouse. J. Agric. & Life Sci. 46: 179-190 (in Korean).
  19. Yoon, Y. C., J. U. Im, H. T. Kim, Y. J. Kim, and W. M. Suh. 2011. Estimation of surplus solar energy in greenhouse based on region. J. Agric. & Life Sci. 45: 135-141 (in Korean).
  20. Yoon, Y. C., Y. H. Bae, Y. S. Ryou, S. H. Lee, and W. M. Suh. 2009. Power generating performance of photovoltaic power system for greenhouse equipment operation. J. Bio-Env. Cont. 18: 177-184 (in Korean).
  21. Yoon, Y. C., W. M. Suh, and S. G. Lee. 1998. A study on the greenhouse heating performance of heat pump system. Magazine of the KSAE. 40: 94-102 (in Korean).
  22. Yun, S. W., M. K. Choi, H. T. Kim, and Y. C. Yoon. 2013a. Performance analysis of photovoltaic power generator by usage battery charge. Protected Hort. Plant Fac. 22: 220-227 (in Korean). https://doi.org/10.12791/KSBEC.2013.22.3.220
  23. Yun, S. W., Y. S. Shin, M. K. Choi, H. T. Kim, and Y. C. Yoon. 2013b. Experimental study on the use of solar energy. J. Agric. & Life Sci. 47: 127-134. (in Korean). https://doi.org/10.14397/jals.2013.47.6.127