• Title/Summary/Keyword: 아스만 통풍습도계

Search Result 1, Processing Time 0.018 seconds

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.