• Title/Summary/Keyword: 표준온도계

Search Result 19, Processing Time 0.032 seconds

Realization of Triple Point of Ne, $O_2$, Ar, Hg and $H_2O$ for International Comparison of Capsule-type Platinum Resistance Thermometer (캡슐형 백금저항온도계 국제비교를 위한 네온, 산소, 아르곤, 수은 및 물의 삼중점 실현)

  • Kang, Kee-Hoon;Kim, Yong-Gyoo;Gam, Kee-Sool
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.153-162
    • /
    • 2000
  • Triple points of high purity materials have been used to calibrate primarily the capsule-type platinum resistance thermometer (PRT) in the temperature range of the triple point of equilibrium hydrogen (13.8033 K) and water (273.16 K). In this work, triple points of Ne, $O_2$, Ar, Hg and $H_2O$ except for the triple point of equilibrium hydrogen were realized to establish the International Temperature Scale of 1990 (ITS-90). At each fixed point, two capsule-type PRTs, which were selected for the international comparison, were tested two times. The combined uncertainties of the realization of each triple point were calculated considering the type A and type B evaluation. In Korea Research Institute of Standards and Science, the combined standard uncertainties of the defining triple Points by the ITS-90 were estimated to about 0.18 mK for Ne, 0.14 mK for $O_2$, 0.14 mK for Ar, 0.24 mK for Hg and 0.11 mK for $H_2O$, respectively.

  • PDF

Improvement of Spatial Radiance Uniformity of Small Integrating Spheres (소형 적분구의 공간 복사 휘도 균일도 향상 연구)

  • Yong Shim Yoo;Dong Joo Shin;Bong Hak Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.5
    • /
    • pp.202-209
    • /
    • 2023
  • A KRISS-type small integrating sphere with a high spatial radiance uniformity was made using pressed polytetrafluoroethylene (PTFE) and a reflective rod to calibrate the spectral radiance responsivity of absolute radiant thermometers. The spatial radiance uniformity of the KRISS-type small integrating sphere was ±0.009%, five times higher than the best value reported by foreign national metrology institutions thus far. In addition, we improved the spatial radiance uniformity of a commercial sintered PTFE integrating sphere by a factor of 10.

온도표준과 온도센서 특성

  • 이호근
    • Journal of the KSME
    • /
    • v.31 no.6
    • /
    • pp.506-511
    • /
    • 1991
  • 1990년 1월 1일부터는 국제온도눈금 ITS-90에 준하여 국제온도눈금이 농용되게 되었으며, 이 새로운 국제온도눈금은 향후 적어도 약 20년간 국제적으로 적용될 예정이다. 새로운 국제온도 눈금의 제정으로 과거에 비해 660.deg. C-962.deg. C 온도영역에서 약 10mk의 정밀도로 온도를 측정할 수 있게 되었다. 하나의 온도계로 요구되는 전 온도영역을 정확히 측정할 수 있는 온도 계는 없으므로 온도측정 환경과 요구되는 정확도에 따라 적합한 온도센서를 선택하여 사용해야 하며 본 글에서는 대표적인 온도계의 특징에 대해 개설하였다.

  • PDF

Size-of-source Effect and Self-radiation Effect of an Infrared Radiation Thermometer (적외선 복사온도계의 복사원 크기효과 및 자기복사효과)

  • Yoo, Yong-Shim;Kim, Bong-Hwak;Park, Chul-Woung;Park, Seung-Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.133-138
    • /
    • 2010
  • All radiation thermometers have a size-of-source effect (SSE) and a self-radiation effect (SRE). The SSE,defined as dependence of the detector signal of a radiation thermometer on the diameter of a source, is critically dependent on the wavelength since diffraction is the main cause. In this paper, we have measured the SSE and the SRE of TRT2 (Transfer Radiation Thermometer 2, HEITRONICS) widely used as a transfer standard in low and middle temperature range. At $300^{\circ}C$, The radiation temperature difference between the 60 mm diameter blackbody and 10 mm diameter blackbody due to the SSE was estimated to be $3.5^{\circ}C$ in low temperature mode ($8-14\;{\mu}m$) and $0.5^{\circ}C$ in middle temperature mode ($3.9\;{\mu}m$). In addition, the measured radiation temperature difference of the blackbody due to the SRE was found to be 110 mK when the body temperature change of TRT2 was set at $2.6^{\circ}C$.

A study on the system automation of medium-vacuum standard (중진공 표준기 자동화에 관한 연구)

  • 홍승수;임인태;신용현;정광화
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.4
    • /
    • pp.207-213
    • /
    • 2003
  • We have developed the hardware and software for automation of the national medium vacuum standard. The automation is necessary to control and monitor the complex system consists of several vacuum chambers, pumping systems, vacuum gauges, thermometers, and valves. By using the automation program, we have measured volume ratios of the system and performed calibration of a capacitance diaphragm gauge in order to evaluate the system.

Study on Safety Control of The Laser Equipment (레이저 기기의 국제표준 평가 방법 및 안전 관리 방안 연구)

  • Park, Chan-keun;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.419-422
    • /
    • 2016
  • Recently, there are a lot of report about the safety accident in laser equipment for example laser pointer, laser level, laser distance meter, temperature measurement equipment and so on. But most of people doesn't care of the safety, and some of the people were damaged by laser in the retina and skin. So in this reaserch So in this thesis, research the safety control rules in global and domestic regulations and international standard IEC 60825-1. From the above research, develop the safety control rules to improve the consumer safety.

  • PDF

Effects of an Aspirated Radiation Shield on Temperature Measurement in a Greenhouse (강제 흡출식 복사선 차폐장치가 온실의 기온측정에 미치는 영향)

  • Jeong, Young Kyun;Lee, Jong Goo;Yun, Sung Wook;Kim, Hyeon Tae;Ahn, Enu Ki;Seo, Jae Seok;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.28 no.1
    • /
    • pp.78-85
    • /
    • 2019
  • This study was designed to examine the performance of an aspirated radiation shield(ARS), which was made at the investigator's lab and characterized by relatively easier making and lower costs based on survey data and reports on errors in its measurements of temperature and relative humidity. The findings were summarized as follows: the ARS and the Jinju weather station made measurements and recorded the range of maximum, average, and minimum temperature at $2.0{\sim}34.1^{\circ}C$, $-6.1{\sim}22.2^{\circ}C$, $-14.0{\sim}15.1^{\circ}C$ and $0.4{\sim}31.5^{\circ}C$, $-5.8{\sim}22.0^{\circ}C$, $-14.1{\sim}16.3^{\circ}C$, respectively. There were no big differences in temperature measurements between the two institutions except that the lowest and highest point of maximum temperature was higher on the campus by $1.6^{\circ}C$ and $2.6^{\circ}C$, respectively. The measurements of ARS were tested against those of a standard thermometer. The results show that the temperature measured by ARS was lower by $-2.0^{\circ}C$ or higher by $1.8^{\circ}C$ than the temperature measured by a standard thermometer. The analysis results of its correlations with a standard thermometer reveal that the coefficient of determination was 0.99. Temperature was compared between fans and no fans, and the results show that maximum, average, and minimum temperature was higher overall with no fans by $0.5{\sim}7.6^{\circ}C$, $0.3{\sim}4.6^{\circ}C$ and $0.5{\sim}3.9^{\circ}C$, respectively. The daily average relative humidity measurements were compared between ARS and the weather station of Jinju, and the results show that the measurements of ARS were a little bit higher than those of the Jinju weather station. The measurements on June 27, July 26 and 29, and August 20 were relatively higher by 5.7%, 5.2%, 9.1%, and 5.8%, respectively, but differences in the monthly average between the two institutions were trivial at 2.0~3.0%. Relative humidity was in the range of -3.98~+7.78% overall based on measurements with ARS and Assman's psychometer. The study analyzed correlations in relative humidity between the measurements of the Jinju weather station and those of Assman's psychometer and found high correlations between them with the coefficient of determination at 0.94 and 0.97, respectively.

연소진단 용 광대역 코헤런트 반 스톡스 라만 분광기의 제작 및 정확도 분석.

  • Park, Cheol-Ung;Park, Seung-Nam;Han, Jae-Won;Park, Bu-Min;Sin, Hyeon-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 1997.06a
    • /
    • pp.33-44
    • /
    • 1997
  • 연소상태의 온도를 이동하면서 측정할 수 있는 광대역 코헤런트 반스톡스 라만 분광기를 제작하였다. 분광기의 온도 측정 정확도를 향상시키기 위하여 무모드레이저를 제작하여 스톡스광으로 사용하였다. 이동형 CARS 분광기에 적합하도록 CARS신호 측정용 단색기를 제작하여 분광기 내부에 설치 하였다. CARS 분광기의 온도 측정의 정확도를 알아보려고 흑연관 전기로를 이용하여 표준 복사온도계와 CARS 분광기로 측정한 온도의 차이를 측정하였다. 장치의 온도 정확도는 1000 K - 2400 K 사이의 온도영역에서 2%이내 였다. 무모드 색소레이저의 출력 스펙트럼의 시간에 따른 안정도를 측정하여 온도측정에 미치는 오차를 조사한 결과 1500 K에서 5 시간 동안 1.5 %이내 였다. 평면 화염 버너에서 프로판공기 예혼합 화염의 온도 분포를 측정하여 이 장치의 응용 가능성을 확인하였다.

  • PDF

Smart Mobile Services - M2M Technology and Its Standardization Trends (스마트모바일 서비스 - M2M 기술 및 표준 동향)

  • Yoo, S.K.;Hong, Y.G.;Kim, H.J.
    • Electronics and Telecommunications Trends
    • /
    • v.26 no.2
    • /
    • pp.50-60
    • /
    • 2011
  • 정보통신기술의 발달은 개인용 컴퓨터나 노트북 컴퓨터와 같은 컴퓨터를 중심으로 이루어진 네트워킹 및 인터넷 환경을 컴퓨터를 포함한 스마트폰, PDA, 휴대용 멀티미디어 기기와 같이 이동이 가능한 소형의 기기를 중심으로 변화시키고 있다. 그러나, 연산, 통신 및 네트워킹 기능이 가능한 소형 장치들은 정보화 기기뿐만 아니라 계량기, 온도계와 같은 일반적인 사물에도 부착될 수가 있다. 사물에 부착된 이러한 소형 장치들은 사물의 정보를 자동으로 획득하게 해주거나 사물간의 통신 네트워크를 통해 정보의 상호 공유가 가능해진다. 이와 같이 사물에 부착된 통신 장치를 이용하여 사물이 네트워크에 연결되거나 사물간에 통신 네트워크를 구성하여 정보를 공유하는 개념 및 기술을 지칭하는 용어로 IoT, M2M 및 사물지능통신 등이 있다. 이러한 네트워크 환경에서는 사람 대 사람, 사람 대 사물뿐만 아니라 사물 대 사물간의 통신 네트워크가 가능해져 모든 객체간의 정보 공유가 가능해지며 이는 미래 유비쿼터스 정보 서비스 사회로 진화하기 위한 필수적인 기술 요소라 할 수 있을 것이다.

  • PDF