DOI QR코드

DOI QR Code

Evaluation of the Usefulness of Ancillary Devices for Patients with Acute Lumbar Pain During Magnetic Resonance Imaging

자기공명영상검사 시 급성 요추 통증 환자를 위한 보조기구의 유용성 평가

  • Park, Hee-Wang (Dept of Public Health, The Graduate School of Konyang University) ;
  • Lee, Moo-Sik (Dept of Public Health, The Graduate School of Konyang University) ;
  • Kim, Yong-Kwon (Dept of Radiological Science, College of Medical Science, Konyang University) ;
  • Bae, Seok-Hwan (Dept of Radiological Science, College of Medical Science, Konyang University)
  • 박희왕 (건양대학교 일반대학원 보건학과) ;
  • 이무식 (건양대학교 일반대학원 보건학과) ;
  • 김용권 (건양대학교 의과학대학 방사선학과) ;
  • 배석환 (건양대학교 의과학대학 방사선학과)
  • Received : 2018.05.03
  • Accepted : 2018.06.28
  • Published : 2018.06.30

Abstract

The purpose of this study was to evaluate the convenience and image quality of patients with acute lumbar pain patients at a general hospital in Daejeon using ancillary devices for postural changes and correction. The results of the study are summarized as follows. First, the Turbo S pin Echo technique(TS E) using ancillary equipment has the highest image evaluation rating with an average score of 4.440, which is highly valuable on a diagnosis. Second, the average score for patient the questionnaire 'When using ancillary equipment, I feel that my body is calibrated to side without bias.' was shown as 4.440, which is very useful for the correction of the patient's body when using ancillary equipment. Finally, Breath Hold technique(BH) is very effective in shortening test time of acute lumbar pain patients, because it can reduce test time 86.4% faster than Turbo Spin Echo technique(TSE). The results of the study showed that the use of ancillary equipment to perform the test through the side lying postures helped to reduce the pain and control the patient's breathing, and the diagnostic value of the image was high.

Keywords

References

  1. KIM HG. Clinical Findings on Vertebral Compression Fracture Diagnosed with MRI. Journal of radiological science and technology. 2005;28(2):219-226.
  2. LEE JH, LEE JS, LIM IC. Evaluated the L-spine Magnetic Resonance Imaging for the Scanning Method of the Lateral Recumbent Position with to the Embarrassed Control of the Acute Low Back Pain. Journal of radiological science and technology. 2014;8(5):255-260
  3. KIM YH. Comparison of Turbo Spin Echo and HASTE Pulse Sequence in Brain MRI. Journal of the Korean Radiological Society. 1997;37(4):583-588 https://doi.org/10.3348/jkrs.1997.37.4.583
  4. Norbash AM, Glover GH, Enzmann DR. Intracerebral lesion contrast with spin echo and fast spin-echo pulse sequences. Radiology 1992;185:661-665. https://doi.org/10.1148/radiology.185.3.1438742
  5. Jones KM, Mulkern RV, Mantello MT, Melki PS, Ahn SS, Barnes PD, Jolesz FA. Brain hemorrhage: evaluation with fast spin-echo and conventional dual spin-echo images. Radiology 1992;182:53-58. https://doi.org/10.1148/radiology.182.1.1727309
  6. Ahn SS, Mnatello MT, Jones KM, Mulkern RV, Melki PS, Higuchi N, Barnes PD. Rapid imaging of the pediatric brain using the fast spin-echo technique. AJNR 1992;13:1169-1177.
  7. Fulbright R, Panush D, Sze G, Smith RC, Constable T. MR of the head and neck: comparision of fast spin-echo and conventional spin-echo sequences. AJNR 1994;15:767-777.
  8. Tice HM, Jones KM, Mulkern RV, Schwartz RB, Kalina P, Ahn S, Barnes P, Jolesz F. Fast spin-echo imaging of intracranial neoplasms. J Comput Assist Tomogr 1993;17:425-431. https://doi.org/10.1097/00004728-199305000-00017
  9. Runge VM, Wood ML. Half-fourier MR imaging of CNS disease. AJNR 1990;11:77-82.
  10. Semelka RC, Kejekis NL, Thomasson D, Brown MA, Laub GA. HASTE MR imaging: description of technique and prelimiary results in the abdomen. J Magn Reson Imaging 1996;6:698-699. https://doi.org/10.1002/jmri.1880060420
  11. Aerts P, Hoe LV, Bosmans H, Oyen R, Marchal G, Baert AL. Breath-hold MR urography using the HASTE technique. AJR 1996; 166:543-545. https://doi.org/10.2214/ajr.166.3.8623625
  12. Hoe VL, Bosmans H, Aerts P, Baert Al, Fevery J, Kiefer B, Marchal G. Focal liver lesion: fast T2-weighted MR imaging with half-fourier rapid acquisition with relaxation enhancement. Radiology 1996;201:817-823. https://doi.org/10.1148/radiology.201.3.8939237
  13. Rofsky NM, Lee VS, Laub G, Pollack MA, Krinsky GA, Thomasson D, Ambrosino MM. Weinreb JC. Abdominal MR imaging with a volumetric interpolated breath-hold examination. Radiology 1999;212:876-884. https://doi.org/10.1148/radiology.212.3.r99se34876
  14. Soyer P, Bluemke DA, Bliss DF, Woodhouse CE, Fishman EK. Surgical segmental anatomy of the liver: demonstration with spiral CT during arterial portography and multiplanar reconstruction, Am J Roentgenol 1994;163:99-103. https://doi.org/10.2214/ajr.163.1.8010258