DOI QR코드

DOI QR Code

In the examination of PET/CT, Breast-tool production and availability of using FRP to check for breast disease.

양전자방출전산화단층촬영 검사에서 유방 질환 환자를 검사하기 위해 유리섬유강화플라스틱을 이용한 유방 틀의 제작 및 유용성

  • Kim, Gab-Jung (Department of Radiological Technology, Songho University) ;
  • Jeon, Min-Cheol (Department of Radiological Technology, Daejeon Health Institute of Technology) ;
  • Han, Man-Seok (Department of Radiological Science, Kangwon National University) ;
  • Seo, Sun-Youl (Department of Radiology, Eulji University Hospital) ;
  • Kim, Nak-Sang (Department of Radiological Technology, Songho University) ;
  • Bae, Won-Gyu (Department of nuclear medicine, Ajou University hospital)
  • 김갑중 (송호대학교 방사선과) ;
  • 전민철 (대전보건대학교 방사선과) ;
  • 한만석 (강원대학교 방사선과) ;
  • 서선열 (을지대학교병원 영상의학과) ;
  • 김낙상 (송호대학교 방사선과) ;
  • 배원규 (아주대학교병원 핵의학과)
  • Received : 2017.08.03
  • Accepted : 2017.09.20
  • Published : 2017.09.28

Abstract

The purpose of this study is to evaluate the breast tool to improve the diagnostic value of the image in the breast examination. Breast tool was made of using FRP. And then it was compared by radioactivity counting rate and image. In the evaluation of the Breast tool, the left and right counts per $1{\mu}Ci$ are 185 counts and 189 counts, respectively. The image obtained in the prone position was close to the circle. To increase diagnostic value of image, it is considered to use Breast-tool in the breast examination.

유방검사에서 영상의 진단 가치를 높일 수 있는 유방틀을 제작하여 유용성을 평가하고자 한다. 유리섬유강화플라스틱을 이용해서 유방틀을 제작하였다. 그리고 방사능계수율과 획득된 영상을 비교하였다. 유방틀의 평가에서 왼쪽과 오른쪽이 $1{\mu}Ci$ 당 counts가 각각 185 counts, 189 counts이다. 그리고 복와위 자세에서 획득된 영상은 원형에 가깝게 나타났다. 유방틀을 이용함으로써 진단 가치를 높일 수 있어 유방촬영 검사를 하는데 있어 유용할 것으로 사료된다.

Keywords

References

  1. Korea Central Cancer Registry NCC. Annual report of cancer statistics in Korea in 2013. 2015.
  2. K. Y. Park, M. J. Kim, Y. O. Yang, "Factors Relating to Quality of Life in Korean Breast Cancer Patients: Systematic Review and Meta-analysis". J of Korean Acad Fundam Nurs, Vol. 24, No. 2, pp. 95-105, 2017. https://doi.org/10.7739/jkafn.2017.24.2.95
  3. S. H. Mun, "Convergence Study on Factors that Influence Cancer Screening Rate in Korea and Japan". J of The Korea Convergence Society, Vol. 6, No. 6, pp. 247-253, 2015. https://doi.org/10.15207/JKCS.2015.6.6.247
  4. Miles A CJ, Smith RA, Wardle, "A perspective from countries using orginized screening programs". Cancer, Vol. 101, No. 5, pp. 1201-1213, 2004. https://doi.org/10.1002/cncr.20505
  5. C. Y. Lee, H. S. Kim, I. S. Ko, "Outcome Evaluation of Community Breast Cancer Prevention Program". College of Nursing Yonsei University, 2001.
  6. K. S. Choi, H. R. Shin, C. M Kim, D. K Oh, "National Cancer Screening Program in Korea". J of Korean Association of Cancer Prevention. Vol. 9, No. 2, pp. 116-122, 2004.
  7. H. J. Kim, C. L. Lee, "PACS and Medical Imaging Display Systems". J of the Korean Society for Precision Engineering, Vol. 25, No. 1, pp. 22-34, 2008.
  8. C. G. Kim, "Spatial dose distribution and exposure dose during lumbar lateral test". J of The Korea Convergence Society, Vol. 5, No. 1, pp. 17-22, 2014. https://doi.org/10.15207/JKCS.2014.5.1.017
  9. DW T, "A combined PET/CT scanner: the choices". J of Nucl Med. 2001.
  10. W. H. Kim, H. S. Go, J. E. Lee, H. S. Kim, J. K. Ryu, W. Y. Jung, "The Comparison Evaluation of SUV Using Different CT Devices in PET/CT Scans". J of Nucle Med Technol, Vol. 18, No. 1, pp. 10-18, 2014.
  11. H. H Park, S. Y. Kim, J. J. Kim, M. S. Park, H. S. Lim, S. Jung, C. G. Kang, J. S. Kim, C. H. Lee, "Usefulness of Prone Position on PET-CT in Breast Cancer". J of Nucle Med Technol, Vol. 12, No. 1, pp. 44-48, 2008.
  12. D. I. Chang, J. W. Koh, "Flexural Behavior of Glass Fiber Reinforced Plastic Pipes". J of The Korea Concrete Institute, Vol. 5, No. 3, pp. 187-197, 1993.
  13. M. S. Kang, W. P. Lee, "Characteristics of tool wear in cutting glass fiber reinforced plastics : the effect of physical properties of tool materials". International J of Automotive Technology, Vol. 10, No. 1, pp. 33-41, 1988.
  14. C. H. Um, S. W. Yoo, "An Experimental Study for Flexural Failure Behavior of Composite Beam With Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Permanent and Tensile Reinforcement". Vol. 35, No. 5, pp. 1015-1024, 2015. https://doi.org/10.12652/Ksce.2015.35.5.1015
  15. L. C. Bank, "Composites for construction: Structural design with FRP materials". John Wiely & Sons, NJ, USA, 2006.