DOI QR코드

DOI QR Code

원내 공기감염 확산 방지를 위한 격리병실의 CFD 해석

CFD Simulation of the AII-Room for Preventing Spread of the Air-Borne Infection in Hospital

  • 투고 : 2016.09.25
  • 심사 : 2017.02.01
  • 발행 : 2017.03.30

초록

The present study is a foundational study for performance improvements on isolation wards to prevent proliferation of secondary infection of infectious diseases such as SARS, H1N1, and MERS inside hospitals. Accordingly, the present study conducted an analysis of the effect of sealing mechanisms and filling of openings on ensuring air tightness performance in isolation wards as well as simulation on air currents in improved isolation wards. The study method is as follows: first, previous studies on aerial infection types and mechanisms were reviewed and the review results were utilized as basic data for analysis of the simulation of air currents. Second, national and international legislations and regulations in relation to isolation wards as well as case studies on developed nations were investigated in order to identify the problems in isolation wards in Korea and improvement plans. Third, construction and facility plans were compared and analyzed between general and isolation wards focusing on large general hospitals in Korea thereby conducting comparison and analysis on the performance and effects of air-tightness of general and isolation wards through simulations(CFD). Fourth, an analysis on air currents in isolation wards specified in mandatory legislation (draft) from the Ministry of Health and Welfare such as fulfillment of isolation ward requirements including negative pressure isolation wards, areas of ward and intensive care units, and ensuring separation distance between sickbeds was conducted. The study result showed that isolation wards had better air-tightness performance than that of general wards and parallel bed layout was better than serial bed layout in terms of aerial infection substance proliferation. In addition, when a separation distance between sickbeds was 2m or wider, the risk of aerial infection became significantly lower.

키워드

과제정보

연구 과제 주관 기관 : 한국연구재단

참고문헌

  1. Centers for Diease Control&Prevention. (2015). Infection Diseases Surveillance Yearbook, CDC
  2. Ministry of Health and Welfare. (2015). Hospital which MERS patients were founded, Ministry of Health and Welfare
  3. SAREK, (2016). Determination of the separation between rooms, ward rooms, hospital beds, and separation of beds and beds in hospital rooms, presidential commission on architecture policy
  4. Doopedia. (2016). Aerial(Airborne) infection
  5. Sung. M. (2015). Hospital's air conditioning and control of infection through MERS. The magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea 44(8). 58-64
  6. Lee, S. (2015). Prevented technique for infection at Hospital. The magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea 44(3). 64-75
  7. Catherine, J., & P, Andrew Sleigh.. (2008). Applying the Wells-Riley equation to the risk of airborne infection in hospital environments: The importance of stochastic and proximity effects, Indoor Air, 17-22
  8. WHO, (2007). Wells-Reiley equation
  9. Contemporary Architecture Committee of terms Compilation, (2011). A glossary of architectural terms
  10. Centers for Disease Control&Prevention, (2014). Guidelines for Environmental Infection Control in Healthcare Facilities, CDC
  11. Ministry of Health and Welfare. (2011). Operation and management of Government designated hospital treatment (isolation) beds (Plan), Ministry of Health and Welfare of Korea
  12. Lee, S. (2015). A case study and response plan in design for prevention of secondary infection in hospital, The magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea 44(8). 68-75
  13. Lim, T. (2009). A Inquiry of Tracer Gas for Analysis of Daspersion and Prediction of Infection Possibillity according to Airborne Viral Contaminants, Jounal of the Korean Institute of Interior Design 18(3)
  14. Bang, J. (2016). Study on air migration in negative pressure isolation room during door openings and human movement, Architectural Institute of Korea Annual Conference 2016.04, 265-266
  15. Presidential Commission on Architecture Policy. (2016). A study on the formation of safety and healthy indoor environment by improvement of indoor air quality of medical and multi-use facilities

피인용 문헌

  1. Case Study of Airborne Pathogen Dispersion Patterns in Emergency Departments with Different Ventilation and Partition Conditions vol.15, pp.3, 2018, https://doi.org/10.3390/ijerph15030510
  2. Simulation of splash diffusion analysis for prevention of infection in hospital vol.18, pp.6, 2018, https://doi.org/10.12813/kieae.2018.18.6.121