• Title/Summary/Keyword: 격리병실

Search Result 28, Processing Time 0.02 seconds

Evaluation of Stability using Monte Carlo Simulation in 2 People Isolation Treatment Room of Radiation Iodine (몬테카를로 모의 모사를 이용한 방사성옥소 2인 치료병실의 안전성 평가)

  • Jang, Dong-Gun;Ko, Sung-Jin;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.385-390
    • /
    • 2016
  • Radioactive iodine treatment that uses the 2 people isolation room is to cause unnecessary radiation exposure between patients. This research is to be tested safety of 2 people Isolation treatment room and dose-rate through conservative perspective except physiology characteristic and biology information on the assumption that patient have iodine without excretion in 2 people isolation treatment room. This research shows that 364 keV gamma rays emitted by the radioiodine was to determine that the air layer about 30 cm or lead shield 3 mm a half-layer. In addition, In addition, patients in the distance, and lead shielding, length of hospital stay (48 hours) for external radiation exposure that is received from the other patients, two of treatment as appears to be lower than the legal isolation standard dose less than 5 mSv isolation room effective analyzed that manageable.

A Study on the Room Conversion Type when Converting a Patient Bed-Room into a Negative Pressure Isolation Room - Focused on Nationally designated Isolation Wards and Urgent Isolation Wards (일반병실을 음압격리병실로 전환 시 병실 전환 방식에 관한 연구 - 국가지정입원치료병상과 긴급치료병상을 중심으로)

  • Kim, Jiyoon;Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose: The 2015 Middle East Respiratory Syndrome (MERS) outbreak and the recent COVID-19 pandemic have highlighted the lack of negative pressure isolation rooms and the fragility of the healthcare system. The need for healthcare facility transformation for respiratory infectious diseases has become more prominent due to COVID-19, and the purpose of this study is to provide a foundation for the rapid, economical, and safe construction of negative pressure isolation wards. Methods: This study analyzes the current status of hospitals that have been converted to negative pressure isolation rooms, and provides architectural plans and examples to provide a reference for bedroom change. Research data of this study have been obtained by analyzing the drawings of negative pressure isolation wards of nationally designated inpatient treatment beds and urgent isolation beds. In addition, the relevant literature of urgent isolation beds has been analyzed to derive bedroom change type. Result: In this study, a total of 21 isolation bed conversion methods have been presented. Implications: In order to change efficiently from a general ward to an isolation ward, it is necessary to consider the actual hospital's infectious disease transmission patterns and facility conditions.

방사성옥소 치료를 위한 표준 지침서 개발과 치료병실 환경 개선 연구

  • Kim, Bong-Soo;Pyo, Seong-Jae;Kim, Chang-Ho;Jo, Yong-Gwi;Sin, Chae-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.126-129
    • /
    • 2008
  • 목적: 방사성옥소 치료 환자들은 주의 사항이나 식이요법 등을 지키는 것에 대한 어려움과 3~4일간의 격리 치료기간 동안의 막연한 불안감을 느끼는 등의 심리적, 신체적 부담감을 가지고 있다. 본 과에서는 방사성옥소 치료의 예약과 치료병실에 대한 표준지침서를 개발하여 환자들에게는 정확하고 쉬운 정보를 제공하여 막연한 불안감을 해소하고 치료 업무에 종사하는 종사자들에게는 통일된 정보를 제공하여 업무효율을 향상시키는 효과와 치료 병실의 환경개선을 통한 환자의 심리적 안정감을 찾는데 주력하고자 본 연구를 시작하였다. 대상 및 방법: 2006년 9월부터 2007년 2월까지 치료병실에 입원한 환자를 대상으로 치료환자의 치료 일정, 주의사항, 저옥소 식단과 치료병실의 표준 진료 지침서를 개발하고 치료 병동의 간호사와 협력하여 치료병실의 환경을 개선하여 환자에게 적용하였다. 결과: 방사성옥소 치료의 특성상 환자는 치료가 결정되는 순간부터 치료과정에 대한 이해도 부족과 치료병실 생활에 대한 불안감을 느끼게 되므로 치료 시 사용되는 일정 및 주의사항, 저옥소 식단의 표준지침서를 개발하여 환자 치료병실 개선과 치료병실에서의 표준지침서를 개발하고 사용하였다. 결론: 치료에 따른 진료지침서와 병실 환경을 개선 후 치료에 대한 환자의 이해도 및 치료병실에서의 생활이 예전과 비교해서 많이 향상 되었고 치료의 과정을 설명하는 예약 시에도 많은 도움이 되고 있다. 이러한 치료과정의 규격화 하는 작업들은 본원뿐 아니라 치료병실이 있는 병원의 치료환경을 개선하는데 도움이 될 것이라고 사료된다.

  • PDF

방사성옥소 치료를 받는 갑상선암 환자의 만족도 개선 연구

  • Pyo, Seong-Jae;Kim, Bong-Su;Jo, Yong-Gwi;Sin, Chae-Ho;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.130-136
    • /
    • 2008
  • 목적: 방사성옥소 치료를 받는 많은 환자들이 장기간의 전처치와 격리 입원 동안에 신체적 불편함을 호소하므로 이를 줄여주기 위하여 첫째, 방사성옥소 치료 전 환자들이 저옥소식을 잘 지킬 수 있도록 도움을 주며 둘째, 4일간의 격리입원기간 동안 심리적 어려움과 신체 적불편함을 줄여줌으로써 환자의 만족도를 향상시키는 효과를 기대하고자 본 연구를 하였다. 대상 및 방법: 1. 연구자들의 브레인스토밍을 통해 환자들의 불편함을 파악하였다. 2. 방사성옥소 치료를 위해 입원한 환자 36명에게 입원 기간 동안 느낀 점을 기록하게 하고 이를 조사하였다. 3. 환자 퇴원시에 치료과정에 대한 만족도 설문을 문제점 개선 전 33명, 개선 후 22명에게 조사하였다. 결과: 문제점과 개선안을 도출하였으며 가능한 범위 내에서 개선활동을 실시하였다. 그리고 만족도 설문을 조사하였으며 개선 전 후를 비교하였다. 문제점으로 1) 저옥소식: 맛이 없다, 반찬 가려 먹기가 어렵다. 2) 치료병실 생활: 속이 메스꺼워 음식 섭취가 곤란하다, 병실이 춥다. 3) 호르몬제 투여중지: 전신이 나른하다, 몸이 붓는다가 도출되었으며 이를 해결하기 위한 개선 활동은 1) 입원 전 예약 시에 음식조절(저옥소식)에 대한 설명을 자세히 하였다. 2) 타부서와의 협의-협조사항(치료병실의 청결유지와 쾌적한 병실을 만들기 위해 16층 병동과 협의, 저옥소식 영양상담을 치료 과정중에 넣기 위해 영양과와 협의, 온열매트리스 설치와 보온이불 구입을 위해 시설팀과 협의 등)을 해결하려 노력했다. 3) 전반적인 개선활동(방사성옥소를 차질없이 구입, 치료병실의 치료 전 후 방사능오염 방지, 환자의 심리적 불안감 해소 등)을 하였다. 환자의 만족도 설문에 대한 개선 활동 전 후 비교 결과에서 '치료과정 전체에 대해 힘들었다'는 개선 전 후에 각각 80.6%, 81.8%로 큰 차이가 없었다. 또한 문제점으로 도출된 '저옥소식이 힘들었다'는 개선 전 후에 각각 24.1%, 27.8%로 역시 큰 차이가 없었다. 그러나 '병실생활이 힘들었다'는 개선 전 후에 각각 48.3%, 72.2%로 큰 차이를 보였다. 그리고 '호르몬 투여중지로 인해 힘들었다'는 개선 전 후에 각각 27.6%, 0%로 큰 차이를 보였다. 고찰 및 결론: 환자들의 불편함을 줄여주기 위하여 연구자들의 개선활동이 있었고 그 중에서 입원병실의 생활환경이 특히 향상되었다. 그러나 결과에서 '병실생활이 힘들었다'에 대한 답의 비율은 오히려 더 높아졌다. 이는 '호르몬 투여 중지로 힘들었다'로 답하는 환자의 비율이 상대적으로 줄었기 때문에 높아진 것으로 생각되었다. 방사성옥소 치료로 인해 생길 수밖에 없는 신체적 반응 때문에 대부분의 환자들은 항상 힘들었다고 할 것이다. 만족도 개선 활동으로 환자의 힘든 치료과정을 완전히 해소시켜 줄 수는 없었으나 환자입장에서 생각할 수 있게 된 계기가 되었으며 좀 더 향상된 치료환경을 제공하는 기회가 되었다.

  • PDF

Using Design to Make Doffing of Personal Protective Equipment Safer for Healthcare Workers (의료종사자의 안전한 개인보호장비 탈의를 위한 공간 설계에 관한 연구)

  • Matic, Zorana;Oh, Yeinn;Lim, Lisa
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.3
    • /
    • pp.17-26
    • /
    • 2020
  • Purpose: This paper presents research evidence that the environmental design of the doffing area in a biocontainment unit (BCU) can have a measurable impact on increasing the safety of frontline healthcare workers (HCW) during doffing of high-level personal protective equipment (PPE), and proposes optimized biocontainment unit design. Methods: From 2016 to 2019, The SimTigrate Design Lab conducted 3 consecutive studies, focusing on ways in which the built environment may support or hinder safe doffing. In the first study, to identify the risky behaviors, we observed 56 simulation exercises with HCWs in 4 BCUs and 1 high-fidelity BCU mockup. In the second study, we tested the effectiveness of a redesigned doffing area on improving the HCWs performance and used simulation, observation, and rapid prototyping in 1 high-fidelity mockup of a doffing area. In a follow-up study, we used simulation and co-design with HCWs to optimize the design of a safer doffing area in a full-size pediatric BCU mock-up. Results: We identified 11 specific risky behaviors potentially leading to occupational injury, or contamination of the PPE, or of the environment. We developed design strategies to create a space for safer doffing. In the second study, in a redesigned doffing area, the overall performance of HCW improved, and we observed a significant decrease in the number of risky behaviors; some risky behaviors were eliminated. There was a significant decrease in physical and cognitive load for the HCWs. Finally, we propose an optimized layout of a BCU for a safer process of PPE doffing. Implications: The proposed BCU design supports better staff communication, efficiency, and automates safer behaviors. Our findings can be used to develop design guidelines for spaces where patients with other highly infectious diseases are treated when the safety of the patient-facing HCWs is of critical importance.

Evaluation on Safety of Two-bed Therapy Rooms (2인용 치료병실 안전성 평가)

  • Lee, Kyung-Jae;Cho, Hyun-Duck;Oh, Chang-Bum;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won;Ahn, Hee-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.75-80
    • /
    • 2011
  • Purpose: Europe and U.S use multi-bed therapy rooms. Hereupon, this study aims to examine the safety when current one-bed therapy rooms in Seoul National University Hospital is changed into two-bed ones. Materials and Methods: This study evaluated external exposure by gamma radiation emitted from other patients and internal and external exposure caused by pollutions from other patients in case that Seoul National University Hospital installs a shielding wall between beds in existing therapy rooms. Results: When internal and external exposure was evaluated to evaluate safety of two-bed hospital rooms, 'isolation amount of patients' 5mSv exposure or below is received according to the Atomic Energy Act. Conclusion: With the increasing number of patients with thyoid cancer, patients using therapy rooms are on the rise. Therefore, improving one-person therapy rooms to two-person ones in line with international trend would increase cost reduction and management efficiency, and patients' alienation and isolation can be reduced to increase healing effects.

  • PDF

A Numerical Study on Pressure Fluctuation and Air Exchange Volume of Door Opening and Closing Speeds in Negative Pressure Isolation Room (음압격리병실에서의 병실 문의 개폐속도에 따른 실간 압력변동 및 공기교환량에 대한 해석적 연구)

  • Kim, Jun Young;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: In this study, through the comparison of the pressure fluctuation and air exchange volume in negative isolation room according to the type of the door and door opening/closing speeds, which is one of the main factors causing the cross contamination of the negative pressure isolation room, establishes standard operating procedures to prevent cross contamination in high risk infectious diseases and isolation room design. Methods: In this study, the air flow each of the room is analyzed using ANASYS CFX CODE for flow analysis. In addition, the grid configuration of the door is constructed by applying Immersed Solid Methods. Results: The pressure fluctuation due to the opening and closing of the hinged door was very large when the moment of the hinged door opened and closed. Especially, at the moment when the door is closed, a pressure reversal phenomenon occurs in which the pressure in the isolation room is larger than the pressure in the anteroom. On the other hand, the pressure fluctuation due to the opening and closing of the sliding door appeared only when the door was closed, but the pressure reversal phenomenon not occurred at the moment when the sliding door was closed, unlike the hinged door. As the opening and closing speed of the hinged door increases, the air exchange volume is increased. However, as the opening and closing speed of the sliding door is decreased, the air exchange volume is increased. Implications: According to the results of this study, it can be concluded that the pressure fluctuation due to the opening and closing of the hinged door is greater than the pressure fluctuation due to the opening and closing of the sliding door. In addition, it can be confirmed that the pressure reversal phenomenon, which may cause to reduce the containment effect in negative pressure isolation room, is caused by the closing of the hinged door. Therefore, it is recommended to install a sliding door to maintain a stable differential pressure in the negative isolation room. Also, as the opening and closing speed of the hinged door is slower and the opening and closing speed of the sliding door is faster, the possibility of cross contamination of the room can be reduced. It is therefore necessary to establish standard operating procedures for negative isolation room for door opening and closing speeds.

Comparison of pollutant removal efficiency according to the locations of the supply and exhaust (격리병실내 급배기구 위치에 따른 오염물 제거효율 비교)

  • Won, An-Na
    • Journal of Urban Science
    • /
    • v.9 no.2
    • /
    • pp.13-20
    • /
    • 2020
  • The Recently, several countries have been affected by respiratory diseases, resulting in renewed research interest in their prevention and control. One such example was the 2015 outbreak of Middle East Respiratory Syndrome (MERS) in South Korea and COVID-19. In this study, we performed experiments and simulations based on concentration decay using CO2 as the tracer gas to elucidate the pollutant-removal efficiency for different inlet and exhaust locations and outdoor air-supply ratios. The wall inlet exhibited a higher pollutant-removal efficiency, owing to the upward movement of the air from the lower zone to the upper one. In conclusion, it is recommended that a total air-conditioning plan for isolation rooms be established as well as efficient system operation for pollutant removal and air-flow control to prevent the transmission of infections from the patients to others.

A Design Methodology for the Temporary Isolation Room Based on the MERS-Cov Infection Control Guideline - In Case of Temporary Negative Pressure Isolation Room Using Shipping Container - (메르스 감염관리지침에 따른 감염병 임시 격리병동 계획방법에 관한 연구 - 컨테이너를 이용한 음압격리병동을 중심으로 -)

  • Lee, Sang-Hyun;Lee, Jin-Woo
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.33 no.12
    • /
    • pp.19-28
    • /
    • 2017
  • The purpose of this study is to propose a design methodology to build temporary isolation rooms when infectious diseases suddenly occur in a certain region, such as the case of MERS-Cov in South Korea in 2015. Although most big hospitals usually have isolation rooms, they are expensive and dangerous to run such facilities on normal and typical days. To deal with these problems in this research, shipping containers are chosen as devices used to build the temporary isolation rooms near the original hospital. To do so, firstly, a prototype for the temporary isolation room was designed with the three part modules. The first part is for the medical team; the second part including the isolation rooms is for patients; the third part is for medical selection rooms to test the specimens. Secondly, the plan was compared with the MERS-Cov infection control guidelines. Finally this prototype is applied into the Yong-in Yon-sei severance hospital and then evaluated through a CFD simulation using STAR-CCM+(ver.9.06) for checking infectious bacterium movement in this prototype. The result showed that the prototype is effectively safe for patients tested as negative, patients waiting to be tested, and the medical team.