DOI QR코드

DOI QR Code

Effect of Bending Angle and Embedment Length on the Bond Characteristics of V-shaped Tie Reinforcement

절곡각 및 묻힘길이에 따른 V형 띠철근의 부착특성

  • Kim, Won-Woo (Department of Architectural Engineering, Kyeonggi University) ;
  • Yang, Keun-Hyeok (Department of Plant.Architectural Engineering, Kyeonggi University)
  • Received : 2015.04.22
  • Accepted : 2015.07.13
  • Published : 2015.10.20

Abstract

This study proposed V-shaped tie bar method as an alternative of internal cross-tie for reinforced concrete columns in order to enhance the constructability and confinement effectiveness of the lateral tie bars. A total of 35 pull-out specimens were prepared with the parameters of concrete compressive strength and bending angle and embedment length of the V-shaped bar to examine the bond stress-slip relationship of the V-shaped tie bar. The bond strength of the V-shaped tie bars with the bending angle not exceeding $60^{\circ}$ was higher than the predictions obtained from the equations of CEB-FIP provision. Considering the constructability and bond behavior of the V-shpaed tie bar, the bending angle and embedment length of such bar can be optimally recommended as $45^{\circ}$ and 6db, respectively, where db is the diameter of the tie bar.

철근콘크리트 기둥에서 횡 보강근의 시공성 및 구속효과를 향상시키기 위하여 본 연구에서는 내부 크로스타이의 대체로서 V형 띠철근의 배근방법을 제시하였다. 제시된 V형 띠철근의 부착응력-미끄러짐 관계를 파악하기 위하여 콘크리트 강도 및 V형 띠철근의 절곡각도와 묻힘길이를 주요변수로 35개의 직접인발 실험체를 제작하였다. V형 띠철근의 부착강도는 절곡각도가 $60^{\circ}$ 이하에서 CEB-FIP 기준 식보다 높게 있었다. V형 띠철근의 시공성 및 부착거동을 고려하면, V형 띠철근의 최적 절곡각도 및 묻힘길이는 각각 $45^{\circ}$$6d_b$ 이상으로 제시될 수 있었는데, 여기서 $d_b$는 띠철근 직경이다.

Keywords

References

  1. Korea Concrete Institute. Concrete Design Code and Commentary. Kimoondang Publishing Company. 2012.
  2. American Concrete Institute. Building Code Requirements for Structural Concrete and Commentary. ACI 318-11. 2011.
  3. Lee YH. An Experimental Study on the Strength and Ductility of High-Strength Concrete Columns Confined by Lateral Ties Under Axial Loads [dissertation]. Seoul: Chung-Ang University; 2001. 143 p.
  4. Korea Concrete Institute. Standard Specification for Concrete. Kimoondang Publishing Company. 2009.
  5. Chun SC, Kim DY. Design Considerations and Pull-Out Behavior of Mechanical Anchor of Reinforcement. Journal of the Korea Concrete Institute. 2001 Dec;13(6):593-601. https://doi.org/10.22636/JKCI.2001.13.6.593
  6. Han BS, Kim JK, Shin SW. Evaluation of Confinement Effect of High Strength Concrete Confined with Transverse Ties in Reinforced Concrete Columns. Journal of Architectural Institute of Korea. 2008 Mar;24(3):3-10.
  7. Comite Euro-International Du Beton. Ceb-fip Model Code 1990. Thomas Telforld. 1991. 437 p.
  8. Kim BJ, Jin IG, Choi HB, Kang KI. The Effect of Form Oils on Bond Characteristics of Reinforced Concrete Members. Journal of Architectural Institute of Korea. 2007 Dec;23(12):89-96.

Cited by

  1. Axial Compression Performance of Reinforced Concrete Short Columns with Supplementary V-Shaped Ties vol.113, pp.6, 2016, https://doi.org/10.14359/51689159
  2. Lateral Confinement Effectiveness of V-Shaped Supplementary Ties in RC Columns subjected to Axial Compressive Loads vol.32, pp.3, 2016, https://doi.org/10.5659/JAIK_SC.2016.32.3.11