Abstract
Recently, the earthquake has been increasing a lot, damage of electric power facility has been serious as well. Nowadays, the importance of pipe support system such as Hanger, Brace, Snubber connecting the main structure have been emphasized. These devices can prevent pipe from damage so that reduce the vibration and shock acting on the pipe. For this reason, the FCD(Friction Concave Damper) was developed and has been expected to reduce the vibration on the pipe through the Friction Pendulum System. This paper was described the introduction of self-developed mechanical damper using the friction pendulum principle and the characteristic test was performed to verify the performance of the device. Additionally the test results have been compared with predicted F.A.P(FCD Analysis Program-self developed) results. As a result, reliability of design could be improved.
최근 지진의 빈도가 증가하면서 전력 시설물에 대한 피해 역시 심각한 상황이다. 요즘 들어 Hanger, Brace, Snubber와 같이 주요기기들을 연결하는 배관지지 시스템의 중요성이 강조되고 있다. 배관의 손상은 발전소 가동에 전체적인 영향을 미치기 때문에 손상을 주는 요인으로부터 보호할지지 장치가 필요하게 된다. 이러한 장치들은 배관에 작용하는 직 간접적인 진동과 충격을 저감시키는 역할을 하기 때문에 배관의 손상을 방지할 수 있다. 본 논문에서는 마찰진자 원리를 이용한 기계식 댐퍼를 개발하고 특성시험을 통해 장치 성능을 검증한 내용을 기술하였다. 또한 자체 개발한 설계 프로그램을 통해 예상된 해석값과 시험값을 비교분석하였고 결과적으로 설계의 신뢰성을 향상시켰다.