• Title/Summary/Keyword: Zone model

Search Result 2,399, Processing Time 0.059 seconds

Development of the Two-Zone Model to Estimate the Air Quality in Indoor Environments (실내 공기질 평가를 위한 2구획 모델의 개발)

  • 조석호;양성환;이봉헌;정성욱;이병호
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.745-751
    • /
    • 1998
  • The well-mixed room model has been traditionally used to predict the concentrations of contaminants in indoor environments. However, this is inappropriate because the flow fields in many indoor environments distribute contaminants non-uniformly, due to imperfect air mixing. Thus, some means used to describe an imperfectly mixed room are needed. The simplest model that accounts for imperfect air mixing is a two-zone model. Therefore, this study on development of computer program far the two-zone model is carried out to propose techniques of estimating the concentration of contaminants in the room. To do this, an important consideration is to divide a room into two-zone, i.e. the lower and upper zone assuming that the air and contaminants are well mixed within each zone. And between the zones the air recirculation is characterized through the air exchange parameter. By this basic assumption, the equations for the conservation of mass are derived for each zone. These equations are solved by using the computational technique. The language used to develope the program is a VISUAL BASIC. The value of air exchange coefficient($f_12$) is the most difficult to forecast when the concentrations of contaminants in an imperfectly mixed room are estimated by the two-zone model. But, as the value of $f_12$ increases, the air exchange between each zone increases. When the value of $f_12$ is approximately 15, the concentrations in both zone approach each other, and the entire room may be approximately treated as a single well-mixed room. Therefore, this study is available for designing of the ventilation to improve the air quality of indoor environments. Also, the two-zone model produces the theoretical base which may be extended to the theory for the multi-zone model, that will be contributed to estimate the air pollution in large enclosures, such as shopping malls, atria buildings, atria terminals, and covered sports stadia.

  • PDF

Stress Analysis on Weld Zone of Railway Bogie Frame Using Coupling Model (커플링 모델을 이용한 대차프레임 용접부 응력 해석)

  • Jung, Soon-Chul;Jun, Hyun-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.830-835
    • /
    • 2007
  • In this paper, stress analyses using shell and solid elements on weld zone of railway bogie frame were performed. To calculate stress distribution on weld zone, a coupling model using shell and solid elements was suggested. For this purpose, we performed specimen analyses on T-type solid and shell model of T-type panels which were modeled using shell elements, solid elements and coupled elements, respectively. The result showed that the stress concentration at weld zone was occurred in solid model, but it didn't occur in shell model. And the stress distribution of coupled model was similar to that of solid model. Also, we applied the coupled modeling method on the analysis on weld zone of bogie frame. The stress distribution of coupled model showed much higher compared to that of shell only model. Therefore, the coupled model method is highly recommended for the stress analysis in weld zone of bogie frame.

  • PDF

Drawing of Concentric Zone Border Line using Landsat TM Images

  • Sato, Kiyotada;Yokoyama, Ryuzo
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.13-14
    • /
    • 2003
  • Burgess?s concentric zone model is a famous theory in the geography of city. However, the zone border line drawing method was uncertain. We have developed the method of drawing the border using land use images.

  • PDF

Off-design Performance Prediction of Centrifugal Pumps by Using TEIS model and Two-zone model (TEIS 모델과 두 영역 모델을 이용한 원심 펌프의 탈 설계 성능 예측)

  • Yoon, In-Ho;Baek, Je-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.574-579
    • /
    • 2000
  • In this study. an off-design performance prediction program for centrifugal pumps is developed. To estimate the losses in an impeller flow passage, two-zone model and two-element in series(TEIS) model are used. At impeller exit. the mixing process occurs with an increase in entropy. In two-zone model. there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller was calculated by using TEIS model. While internal losses in an impeller an automatically estimated by using the above models, some empirical correlations far estimating external losses. far example, disk friction loss, recirculation loss and leakage loss are used. In order to analyze the vaneless diffuser flow. the momentum equations for the radial and tangential directions are used and solved together with continuity and energy equations.

  • PDF

A Study on Inner Zone Trip Estimation Method in Gravity Model (중력모형에서 존내 분포통행 예측방법에 관한 연구)

  • Ryu, Yeong Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.763-769
    • /
    • 2006
  • Gravity Model estimates target year's distributed trips using three variables like as origin zone's trip production, destination zone's trip attraction and traffic impedance between origin zone centroid and destination zone centroid. Estimating inner zone trip by gravity model is impossible because traffic impedance of inner zone has "0" value. So till today, for estimating inner zone trips, other methods like growth factor model are used. This study proposed inner zone trip estimation method that calculates inner zone's traffic impedance using established gravity model and estimates inner zone trips by putting calculated traffic impedance into the gravity model. 1988 year's surveyed O-D as basic year's O-D, proposed method's and existing methods(growth factor method and regression model)'s estimated results of 1992 year's and 2004 year's were compared with each year's real O-D by $x^2$, RMSE, Correlation coefficient. And resulted that the proposed method is superior than other existing methods.

Sensitivity Analysis on Off-Design Performance of Centrifugal Compressor Due to the Parameters of Two-zone Model and TEIS Model (두영역 모델과 직렬두요소 모델의 변수에 의한 원심 압축기 탈설계 성능의 민감도 분석)

  • Yoon, Sung-Ho;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.834-844
    • /
    • 2000
  • In this study, an off-design performance analysis procedure is developed based on Two-zone model and TEIS model. In Two-zone model, there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller is calculated by using TEIS model which regards the impeller as two successive rotating elements in series. At impeller exit, the mixing process occurs with an increase in entropy, that is to say, a decrease in total pressure. In loss models including Two-zone and TEIS model, some empirical parameters have a great influence on overall performance curve. So these parameters' influences on the overall performance curve are investigated and compared with experimental data.

Performance Prediction of Centrifugal Pumps using Two Zone Model (두영역모델을 사용한 원심펌프의 성능예측)

  • Choi, Young-Seok;Shim, Jae-Hyeok;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.33-41
    • /
    • 1998
  • In this study, the performance prediction programs for centrifugal pumps are developed. To estimate the losses in the centrifugal pump impellers, two-zone model and TEIS(two elements in series) model are applied to the program. The basic concept of two zone model considers the primary zone that is an isentropic core flow and the secondary zone that is non-isentropic region at the impeller exit. The flows through two different zones mixed out at the impeller exit and the mixing process occurs with an increase in entropy, a decrease in total pressure. The level of the core flow diffusion in a impeller was calculated using TEIS(two elements in series) model. The effects of various parameters which are used in this program on the prediction of head and efficiency are discussed. The correlation curves to select the effectiveness of the primitive TEIS model were suggested according to the specific speed of the centrifugal pumps.

  • PDF

Performance Prediction of Centrifugal Pumps using a Two Zone Model (두영역모델을 사용한 원심펌프의 성능예측)

  • Choi, Young-Seok;Shim, Jae-Hyeok;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.56-63
    • /
    • 1999
  • In this study, the performance prediction programs for centrifugal pumps are developed. To estimate the losses in the centrifugal pump impellers, a two-zone model and TEIS(two elements in series) model are applied to the program. The basic concept of a two zone model considers the primary zone that is an isentropic core flow and the secondary zone that has a non-isentropic region at the impeller exit. The flow goes through two different zones and is mixed out at the impeller exit and the mixing process occurs with an increase in entropy, a decrease in total pressure. The level of the core flow diffusion in an impeller was calculated using TEIS(two elements in series) model. The effects of various parameters which are used in this program on the prediction of head and efficiency are discussed. The correlation curves used to select the effectiveness of the primitive TEIS model were suggested according to the specific speed of the centrifugal pumps.

  • PDF

COMPREHENSIVE ASSESSMENT MODEL OF ECOLOGICAL RIPARIAN ZONE

  • Xia, Ji-Hong;Wu, Wei;Yan, Zhong-Min
    • Water Engineering Research
    • /
    • v.6 no.4
    • /
    • pp.169-178
    • /
    • 2005
  • Comprehensive assessment of ecological riparian zone is to analyze and evaluate the status of riparian zone ecosystem. The existing problem of the ecosystem can be found through the assessment. The AHP-FUZZY method used in the assessment is based on the hierarchy model of index, grade model of object, and attribution degree of index. Accordingly, the four models have been discussed and presented from the aspect of the stability, landscape, eco-health and eco-safety of riparian zone.

  • PDF

Blast Furnace Modeling for Predicting Cohesive Zone Shape (융착대 예측을 위한 고로공정 모델링)

  • Yang, Kwang-Heok;Choi, Sang-Min;Jung, Jin-Kyung
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.39-45
    • /
    • 2006
  • Analysis of the internal state of the blast furnace is needed to predict and control the operating condition. Especially, it is important to develop modeling of blast furnace for predicting cohesive zone because shape of cohesive zone influences overall operating condition of blast furnace such as gas flow, chemical reactions and temperature. because many previous blast furnace models assumed cohesive zone to be fixed, they can't evaluate change of cohesive zone shape by operation condition such as PCR, blast condition, and production rate. In this study, an axi-symmetric 2-dimensional steady state model is proposed to simulate blast furnace process. In this model, cohesive zone is changed by solid temperature range, FVM is used for numerical simulation. To find location of cohesive zone whole calculation procedure is iterated Until cohesive zone is converged. Through this approach, shape of cohesive zone, velocity, composition and temperature within the furnace are predicted by model.

  • PDF