Abstract
Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.
강재형 댐퍼는 주로 철골구조에서 많이 사용되어 왔으나 최근에 들어 철근콘크리트 건물에도 사용빈도가 증가하는 추세이다. 철근콘크리트 건물에 강재이력댐퍼를 적용하기 위해서는 댐퍼의 접합부재가 댐퍼의 지지능력을 보 및 벽체로 전달하기에 적합한 강도와 강성을 지녀야만 한다. 하지만 균열로 인한 철근콘크리트 요소의 손상은 부득이한 것으로, 댐퍼로부터 지지부재로의 하중전달 메커니즘과 댐퍼 지지부재 이력특성의 규명은 이러한 댐퍼의 거동을 평가하는데 매우 중요하다. 이에 이 연구에서는 EaSy 댐퍼와 같은 강재판형 이력댐퍼의 지지부재와 RC벽체와의 접합상세를 대상으로 실험을 실시하였다. 실험 결과 전단과 관련된 균열의 양과 패턴을 제외하고는 모든 실험체의 파괴패턴은 거의 동일한 것으로 나타났으며, 잘 분산된 균열을 지닌 HD-3 실험체가 에너지소산능력, 강성저하 그리고 강도저하 측면에서 좋은 거동을 보여주었다.