References
- J. H. Choi, S. M. Baek, B. J. Jin, W. J. Choi, C. G. Moon, H. S. Lee and J. I. Yoon, "Performance characteristics of cooler controled capacity using hot-gas bypass," ICHMT CONV-09 Tunisia, pp. 502-505, 2009.
- J. I. Yoon, S. T. Oh, S. M. Baek, J. H. Choi, J. Y. Byun, S. K. Jeong and C. G. Moon, "Temperature control of industrial water cooler using hot-gas bypass," WCSET Bali-2009, pp. 377-381, 2009.
- Y. T. Lee and Y. C. Kim, "Performance characteristics of an inverter heat pump with various expansion devices," Proceedings of the Air-Conditioning and Refrigeration Engineering 1998 Conference, pp. 8-13, 1998(in Korean).
- H. W. Kim, S. M. Baek, C. G. Moon, E. Kim, and J. I. Yoon, "The characteristics on the capacity control of inverter type in an industrial water cooler," ICCHT2010-5th Indonesia, pp. 016-1-016-6, 2010.
- D. S. Yang, G. b. Lee and M. S. Kim, Y. M. Cho, "A Study on the capacity modulation of a variable speed vapor compression system using superheat at the compressor discharge," Proceedings of the SAREK 2004 Winter Annual Conference, p. 99, 2004(in Korean).
- Hua, Li, J. I. Yoon, and S. K. Jeong, "Dynamic characteristics of refrigeration system for control evaporator superheat and compressor capacity", The Korean Society for Power System Engineering, KSPSE The 2004 Spring Conference, pp. 170-174, 2004(in Korean).
- H. S. Yang, H. S. Kim, J. H. Kim, S. B. Kim and J. S. Kim, "Control of refrigerating compressor capacity using inverter," SAREK, vol. 5 no. 2, pp. 97-101, 1993(in Korean).
- Cohen, R, J. F. Hnmilton and J. T. Pearson, "Possible energy conservation through the use of variable-capacity compressor", Proc. Purdue Compressor Technology Cong., Purdue, USA. pp. 50-54, 1974.
- Lida. K, T. Yamamoto, T. Kuroda and H. Hibi, Development of an energy saving oriented variable-capacity system heat pump, ASHRAE Trans. pp. 441-449, 1982.
Cited by
- Comparison of System Performances of Hot-gas Bypass and Compressor Variable Speed Control of Water Coolers for Machine Tools vol.24, pp.1, 2012, https://doi.org/10.6110/KJACR.2012.24.1.001
- Performance characteristics of hot-gas bypass refrigerator with the variation of operation conditions vol.38, pp.9, 2014, https://doi.org/10.5916/jkosme.2014.38.9.1021
- Signal Analysis of Inverter-Type Outdoor Unit for Detecting Operation Changes of Commercial Refrigerator vol.33, pp.6, 2016, https://doi.org/10.7736/KSPE.2016.33.6.517
- 상태공간 모델링에 의한 공작기계용 수냉각기의 최적제어기 설계 vol.23, pp.12, 2011, https://doi.org/10.6110/kjacr.2011.23.12.782
- 부하변화에 따른 hot-gas 바이패스 방식별 성능 비교 vol.18, pp.5, 2011, https://doi.org/10.9726/kspse.2014.18.5.048
- 가변속 냉동시스템의 상태방정식 모델링과 최적제어 vol.26, pp.12, 2011, https://doi.org/10.6110/kjacr.2014.26.12.579
- 중간기 열원수 온도에 따른 만액식 해수냉각시스템의 성능 특성 vol.21, pp.2, 2017, https://doi.org/10.9726/kspse.2017.21.2.064