• Title/Summary/Keyword: 과열도

Search Result 547, Processing Time 0.035 seconds

행정규제 측면에서 본 투기과열지구제의 문제점

  • Jang, Seong-Su
    • 주택과사람들
    • /
    • s.207
    • /
    • pp.22-27
    • /
    • 2007
  • 부산, 대구, 광주광역시 대부분 지역과 경남 양산이 투기과열지구에서 해제된다. 2002년 투기과열지구가 도입된 이후 투기과열지구 해제는 이번이 처음이다. 하지만 지방의 주택시장 침체 문제를 해결하기 위한 근본적인 처방이 필요하다는 지적이 많다.

  • PDF

Performance Characteristics of R744 OTEC Power Cycle with Operation Parameters (운전조건에 따른 R744용 해양온도차 발전 사이클의 성능 특성)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.580-585
    • /
    • 2012
  • In this paper, the cycle performance analysis for condensation and evaporation capacity, total work and efficiency of ocean thermal energy conversion power system using R744 ($CO_2$) is presented to offer the basic design data for the operating parameters of this system. The operating parameters considered in this study include superheating and subcooling degree, evaporation and condensation temperature, pump and turbine efficiency. The main results were summarized as follows : The evaporation capacity of R744 increases with superheating and subcooling degree, but decreases with the increasing condensation temperature. The total work increases with superheating and subcooling degree of R744, but decreases with the increasing evaporating temperature. And, the efficiency increases with subcooling and superheating degree, but decreases with the increasing condensation temperature. Therefore, superheating and subcooling degree, evaporation and condensation temperature and pump and turbine efficiency of R744 OTEC power system have an effect on the evaporation and condensation capacity, total work and efficiency of this system. With a thorough grasp of these effect, it is necessary to design the OTEC power cycle using R744.

Performance Analysis of R744(Carbon Dioxide) for Transcritical Refrigeration System (R744용 초임계 냉동사이클의 성능 분석)

  • Roh, Geun-Sang;Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.1
    • /
    • pp.32-38
    • /
    • 2009
  • In this paper, cycle performance analysis for cooling capacity, compression work and COP of R744($CO_2$) transcritical vapor compression refrigeration system is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include superheating degree, outlet temperature of gas cooler and evaporating temperature in the R744 vapor compression cycle. The main results were summarized as follows : The cooling capacity of R744 increases with superheating degree, but decreases with the increasing evaporating temperature and outlet temperature of gas cooler. The compression work increases with superheating degree and cooling pressure of R744, but decreases with the increasing evaporating temperature. And, The COP increases with outlet temperature and evaporating temperature of R744 gas cooler, but decreases with the increasing superheating degree. Therefore, superheating degree, outlet temperature and evaporating temperature of R744 vapor compression refrigeration system have an effect on the cooling capacity, compression work and COP of this system. With a thorough grasp of these effect, it is necessary to design the compression refrigeration cycle using R744.

Optimal Design of Multi-Fuzzy Controller and Its application to Air Conditioning System (다중 퍼지 제어기의 최적 설계와 에어컨 시스템으로의 적용)

  • Jang, Han-Jong;Choe, Jeong-Nae;O, Seong-Gwon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.313-316
    • /
    • 2008
  • 에어컨 시스템은 압축기(Compressor), 응축기(Condenser), 증발기(Evaporator)와 확장밸브(Expansion Valve)로 구성되며, 에어컨 시스템에서 과열도와 저압(증발기의 압력)은 시스템의 효율 증대 및 성능 개선과 안정성에 대하여 결정적인 영향을 미친다. 따라서, 과열도와 저압을 조절하기 위해, 각각의 압축기내의 인버터 주파수와 확장밸브의 개도 제어가 중요하며 선형과 비선형 시스템 모두에 대하여 견실한 성능을 나타내고, 외란에 대하여 강인한 성능을 보이는 퍼지 제어기를 설계한다. 본 논문에서는 과열도와 저압을 제어하기 위하여, 3대의 확장밸브와 1대의 압축기를 가진 에어컨 시스템에 대하여 다중 퍼지 제어기를 설계한다. 또한, 각 제어 플랜트에 대하여 최적의 퍼지 제어기를 설계하기 위하여 3가지 최적화 알고리즘을 사용한다. 즉, 직렬 유전자 알고리즘(Serial Genetic Algorithm; SGA)과 병렬 유전자 알고리즘인 계층적 공정 경쟁 유전자 알고리즘(Hierarchical Fair Competition Genetic Algorithm; HFCGA), 그리고 Particle Swarm Optimization(PSO)을 사용하여 다중 퍼지 제어기를 최적화하고 시뮬레이션의 결과를 비교한다.

  • PDF

Evaporator Superheat Control of a Multi-type Air-Conditioning/Refrigeration System (멸티형 공조/냉동시스템의 증발기 과열도 제어)

  • 김태섭;홍금식;손현철
    • Journal of Energy Engineering
    • /
    • v.10 no.3
    • /
    • pp.253-265
    • /
    • 2001
  • This paper investigates a PI control problem for the evaporator superheat, i.e., temperature difference between the two-phase region and the exit region of an evaporator, for multi-type air-conditioning/refrigeration system. Mathematical model describing the characteristics of compressor, condenser, evaporator, and electronic expansion valve are first derived. Then, two transfer function from the current input applied to an electronic expansion valve to the wall-temperatures of an evaporator tube at two-phase region and superheated region, respectively, are derived. The stability of the closed loop system with the PI controller designed it analyzed by using Nyquist stability criterion. Simulation results are provided.

  • PDF

An analysis on the characteristics of superheater organization of ORC system for marine waste heat recovery system(WHRS) (선박폐열회수(WHRS) ORC 시스템의 과열기 구성에 따른 특성 해석)

  • Kim, Jong-Kwon;Kim, You-Taek;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.8-14
    • /
    • 2014
  • This research designed Waste Heat Recovery System(WHRS) generation system of 250kW whose working fluid is R-245fa and studied on cycle characteristics by superheater organization. It simulated two conditions; series connection and parallel connection between superheater and evaporator. In simulation of series connection of superheater and evaporator, output of 4.7% could be improved because of the increase of enthalpy by overheating of working fluid. When setting 250kW for target output, cycle flux could be reduced by 4.1%. When setting 250kW as a target output of cycle In parallel connection simulation of superheater and evaporator, cycle flux was reduced as flux of heat source fluid for superheater was increased. So, the maximum 7.9% of working fluid pump's electric power was reduced and there was no big change in cycle efficiency and net efficiency by flux ratio.

지방 투기과열지구 해제 늦출 이유 없다

  • Gang, Hwang-Sik
    • 주택과사람들
    • /
    • s.205
    • /
    • pp.54-55
    • /
    • 2007
  • 건교부가 밝힌 투기과열지구 해제 시한은 분양가상한제가 시행되는 9월 이전으로 지구 해제 방침은 일단 명확한 상태다. 그러나 건설사와 지자체들은 현 지방 시장을 감안할 때 하루가 급하다는 주장을 펴고 있다. 건설교통부에서는 이에 대해 1개월 내에 지방의 투기과열지구 해제를 검토하겠다는 의견을 내놓고 있다.

  • PDF

Investigation and Countermeasure of Sheath Circulating Current in the 362kV GIS (362kV GIS 외함 순환전류에 의한 접지본드 과열현상 및 대책)

  • Lee, J.H.;Kim, S.K.;Kim, S.T.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.546-548
    • /
    • 2003
  • 본 논문에서는 362kV GIS 외함 유도 순환전류에 의한 접지본드과열에 대하여 원인을 분석하고 대책을 마련하는 것을 목적으로한다. 원인분석에는 접지본드 과열현상과 과열원인을 GIB 시스전류계산식을 이용하여 계산결과를 도출하였고 전자과도해석 프로그램(EMTP : Electromagnetic Transient Program)에 의한 분석을 통하여 원인을 분석하고 대책을 마련하여 과열현상을 방지하고자 한다.

  • PDF

The Application of the Induction Heating Technology for the food dryness (식품건조를 위한 유도가열 기술 응용 연구)

  • Ryu M.H.;Baek J.W.;Kim J.H.;Yoo D.W.;Rim G.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1148-1150
    • /
    • 2004
  • 본 논문에서는 $400^{\circ}C$ 이상의 과열 증기발생을 위하여 6kW급 유도가열장치를 개발하여 식품건조 시스템에 적용한 예를 보인다. 유도가열장치는 과열 증기의 온도를 제어하기 위하여 인버터 입력 전압을 $100\sim200V$로 가변제어가 가능하게 하였고, 인버터 입력 전압은 벅컨버터를 사용하여 기준 전압을 과열증기의 온도에 대한 전압 값을 사용하여 제어하였으며, LC 공진에 의해 발생한 전류로 증기 가열 챔버를 유도 가열하여 과열 증기를 발생하게 하였다. 발생한 과열 증기는 식품 건조를 위하여 건조로에 투입되어 고온 건조에서 식품의 건조시간을 단축시킬 수 있었으며, 식품의 손상을 줄일 수 있었다. 이의 검증을 위하여 유도 가열 장치를 설계/제작하여 실험하였으며, 식품 건조 테스트를 행하였다.

  • PDF

Hydration and Textural Characteristics of Brown Treated with Superheated Steam Process (과열 수증기 공정에 의하여 처리한 현미의 수화 및 조직특성)

  • 김철진;이수정;조용진
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.29 no.6
    • /
    • pp.1190-1194
    • /
    • 2000
  • 과열 수증기 공정처리 효과가 현미의 수화 및 조직특성에 미치는 영향을 조사하기 위하여 현미(동진)를 과열수증기의 압력이 $1kg_{f}/$\textrm{cm}^2$$로 유지되는 상태에서 수증기의 온도를 127, 150, 16$0^{\circ}C$로 달리하면서 과열 수증기 처리를 하였다. 수분흡수속도는 수침온도(60~8$0^{\circ}C$)에 따라서 현미와 백미가 각각 0.03569~0.1049 $cm/min^{-1/2}$와 0.03474~0/1618 $cm/min^{-1/2}$의 범위를 보였다. 현미와 백미의 활성화에너지는 각각 6.98 및 9.59 cal/mole을 나타내어 열수화 특성이 다름을 보였다. 한편, 과열 수증기 처리현미의 경우 $65^{\circ}C$에서의 확산계수는 18.96$\times$$10^{-5}$$\textrm{cm}^2$/min)와 처리하지 않은 현미(22.28$\times$$10^{-5}$$\textrm{cm}^2$/min)의 중간 값을 나타내었다. 과열 수증기처리 후 현미의 표면조직은 균열이 발생하였는데, 수증기 온도가 높을수록 균열의 정도가 컸다. 이상과 같은 수증기 처리는 현미 강층의 구조를 변화시킬 뿐만 아니라, 내부 전분층의 부분적 균열에도 효과적으로 작용하는 결과를 보인 것으로 예측된다.

  • PDF