DOI QR코드

DOI QR Code

A Performance Monitoring Method for Combined Cycle Power Plants

복합화력 성능감시 정량화 기법

  • 주용진 (한국전력공사 전력연구원) ;
  • 김시문 (한국전력공사 전력연구원) ;
  • 서석빈 (한국전력공사 전력연구원) ;
  • 김미영 (한국전력공사 전력연구원) ;
  • 마삼선 (한국전력공사 전력연구원) ;
  • 홍진표 (한국전력공사 전력연구원)
  • Published : 2009.10.01

Abstract

This paper outlines how the on-line performance monitoring system can be used to improve the efficiency and maintenance of the equipments. And a method of the heat rate allocation to each equipment was suggested to monitor the performance of combined cycle power plants. This calculates the expected heat rate of current conditions and compares it with actual values. Loss allocation in heat rate is reconciled by calculating the magnitude of the deficiency contributed by major components, such as the gas turbine, heat recovery steam generator, steam turbine and condenser. Expected power output is determined by a detailed model and correction curves of the plant. This simulation models are found to reproduce high accuracy in behavior of the cycle for various operating conditions, both in design and in off-design condition. Errors are lower than 2% in most cases.

Keywords

References

  1. 한국전력공사, 1986, '복합발전'
  2. 한국전력공사, 2009, '에너지원별 발전량'
  3. ASME, 1985, 'Perlonnance Test Codes: Gas Turbine Power Plant PTC 22,' American Society of Mechanical Engineers
  4. ASME, 1981, 'Perfonnance Test Codes: Gas Turbine Heat Recovery Steam Generators PTC 4.4,' American Society of Mechanical Engineers
  5. ASME, 1976, 'Perfonnance Test Codes: Steam Turbines PTC 6,' American Society of Mechanical Engineers
  6. ASME, 1996, 'Perfonnance Test Codes: PTC 46, Overall Plant Perfonnance,' American Society of Mechanical Engineers
  7. GE Enter Software LLC, 2000, 'EfficiencyMap Product Guide'
  8. General Physics, 2000, 'EtaPRO Perfonnance Monitoring Systems Combined Cycle Operation Optimizer,' General Physics Corporation
  9. S. M. Kim and Y. J. Joo, 2005, 'Implementation of on-line Performance monitoring system at Seoincheon and Sinincheon combined cyc1e power plant,' Energy 30, pp. 2383-2401 https://doi.org/10.1016/j.energy.2005.01.001
  10. OSI Software, Inc., 2001, 'Plsystem User Guide'
  11. General Physics Corp, 2004, 'Technical brief, GP releases Virtual PlantTM thennodynamic modeling framework,' General Physics Corporation
  12. RE putmm, 2001, 'Steam surface condensers: Basic principles,perfonnance monitoring and perfonnance,' ASME Press, New York

Cited by

  1. vol.13, pp.1, 2010, https://doi.org/10.5293/KFMA.2010.13.1.063