Browse > Article
http://dx.doi.org/10.5293/KFMA.2009.12.5.039

A Performance Monitoring Method for Combined Cycle Power Plants  

Joo, Yong-Jin (한국전력공사 전력연구원)
Kim, Si-Moon (한국전력공사 전력연구원)
Seo, Seok-Bin (한국전력공사 전력연구원)
Kim, Mi-Young (한국전력공사 전력연구원)
Ma, Sam-Sun (한국전력공사 전력연구원)
Hong, Jin-Pyo (한국전력공사 전력연구원)
Publication Information
Abstract
This paper outlines how the on-line performance monitoring system can be used to improve the efficiency and maintenance of the equipments. And a method of the heat rate allocation to each equipment was suggested to monitor the performance of combined cycle power plants. This calculates the expected heat rate of current conditions and compares it with actual values. Loss allocation in heat rate is reconciled by calculating the magnitude of the deficiency contributed by major components, such as the gas turbine, heat recovery steam generator, steam turbine and condenser. Expected power output is determined by a detailed model and correction curves of the plant. This simulation models are found to reproduce high accuracy in behavior of the cycle for various operating conditions, both in design and in off-design condition. Errors are lower than 2% in most cases.
Keywords
Performance Monitoring; Loss Allocation; Heat Rate; Combined Cycle; Simulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 General Physics, 2000, 'EtaPRO Perfonnance Monitoring Systems Combined Cycle Operation Optimizer,' General Physics Corporation
2 S. M. Kim and Y. J. Joo, 2005, 'Implementation of on-line Performance monitoring system at Seoincheon and Sinincheon combined cyc1e power plant,' Energy 30, pp. 2383-2401   DOI   ScienceOn
3 OSI Software, Inc., 2001, 'Plsystem User Guide'
4 General Physics Corp, 2004, 'Technical brief, GP releases Virtual PlantTM thennodynamic modeling framework,' General Physics Corporation
5 RE putmm, 2001, 'Steam surface condensers: Basic principles,perfonnance monitoring and perfonnance,' ASME Press, New York
6 한국전력공사, 1986, '복합발전'
7 한국전력공사, 2009, '에너지원별 발전량'
8 ASME, 1985, 'Perlonnance Test Codes: Gas Turbine Power Plant PTC 22,' American Society of Mechanical Engineers
9 ASME, 1981, 'Perfonnance Test Codes: Gas Turbine Heat Recovery Steam Generators PTC 4.4,' American Society of Mechanical Engineers
10 ASME, 1976, 'Perfonnance Test Codes: Steam Turbines PTC 6,' American Society of Mechanical Engineers
11 ASME, 1996, 'Perfonnance Test Codes: PTC 46, Overall Plant Perfonnance,' American Society of Mechanical Engineers
12 GE Enter Software LLC, 2000, 'EfficiencyMap Product Guide'