Expected Values for the Analysis of Accommodation and Vergence Dysfunction of Young Adluts

젊은 성인의 조절 및 이향운동 기능장애 분석을 위한 표준 값

  • Baarg, Saang-Bai (Department of Nano-Optical Engineering, Korea Polytechnic University)
  • 박상배 (한국산업기술대학교 나노-광공학과)
  • Received : 2008.10.29
  • Accepted : 2008.12.09
  • Published : 2008.12.31

Abstract

Purpose: The purpose of this study was to determine the expected values of accommodation and vergence system for analysis of binocular vision. Methods: Seventy three healty subjects without past history of eye disease were selected for this study, Patients showing clinical binocular anomalies including manifest squint and intermittent heterotropia were excluded and data was collected on 54 patients(mean age, 25.3${\pm}$2.7 year). Near point of convergence, distance and near phoiras were measured based on objective deviation angle. And then AC/ A ratio, relative accommodation were measured and all of the data were compared with the Morgan's expected values. Results: The values of distance and near heterophoria were 1.24${\pm}$2.72${\Delta}$ and 2.70${\pm}$4.91${\Delta}$ respectively and the gradient AC/A ratio was 3.92${\pm}$2.17${\Delta}$/D which were all about the same compared with the Morgan's expected values. The values of distance negative fusional convergence was same, however, distance positive fusional convergence was 7${\Delta}$ greater than the Morgan's one. There were no significant differences in the range values of both near vergences while the range of distance vergence was relatively larger than the Morgan's one. Positive relative accommodation was +0.37D greater and negative relative accommodation was -0.63D greater than the Morgan's values. Conclusions: The findings in this study appear that the Morgan's expected values have a possibilities of including considerable proximal convergence value. In comparison with Morgan's values, Korean's normal expected values have much different values of especially BO limit, so if the Morgan's values are directly applied to binocular vision analysis for Korean people, it may lead to an inaccurate binocular vision diagnosis. This results can be used to diagnose the accommodation and vergence system of Korean normal young adults.

본 연구는 조절 및 이향운동 기능장애 분석을 위한 표준 값을 알아보기 위해 시행하였다. 방법: 안질환이 없고 현성사시 및 간헐 사시가 없으며 조절 및 이향운동 기능장애가 없는 54명(평균연령 25.3${\pm}$2.7세)을 대상으로 하였다. 객관적 편위각을 기준으로 하여 폭주근점, 원거리 및 근거리 사위량을 측정하였고 이후 AC/A비, 상대조절력 및 이향운동 기능을 측정한 후 이 값들을 Morgan의 표준값과 비교 분석하였다. 결과: 원거리 및 근거리 사위량은 각각 1.24${\pm}$2.72${\Delta}$, 2.70${\pm}$4.91${\Delta}$이었고 렌즈차 이용법에 의한 AC/A비는 3.92${\pm}$2.17${\Delta}$/D로 Morgan의 표준값과 거의 같은 값을 보였다. 원거리 음성융합성폭주량은 동일한 값을 보인반면, 양성융합성폭주량은 Morgan의 표준값에 비해 7${\Delta}$ 높은 값을 보였다. 근거리의 전체 이향운동의 범위는 Morgan 값과 큰 차이를 보이지 않은 반면 원거리의 전체 이향운동의 범위는 양성융합성폭주여력이 상대적으로 더 넓은 범위를 가지는 것으로 나타났다. 양성상대조절력은 +0.37D 높은 값이었고, 음성상대조절력은 -0.63D 더 높은 값을 보였다. 결론: 본 연구에 의한 양안시 분석 값들은 Morgan의 표준값이 상당한 근접성 폭주를 포함하고 있을 가능성을 나타낸다. Morgan 표준값과 비교하여 한국인을 대상으로 한 원거리 및 근거리 이향운동량과 근접성 폭주량은, 특히 BO limit 값에서 매우 다른 값을 보이고 있기 때문에 만약 Morgan 값을 한국인의 양안시 분석에 그대로 적용한다면 부정확한 양안시 진단으로 유도될 수도 있다. 본 연구의 측정값은 한국인 정상 젊은 성인의 양안시 분석을 위한 자료로 활용될 수 있을 것으로 생각한다.

Keywords