• Title/Summary/Keyword: 사위

Search Result 164, Processing Time 0.025 seconds

A Study on the Phoria of Korean Male and Female Adults (한국인 성인 남녀의 사위에 관한 연구)

  • Sung, Duk Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.59-63
    • /
    • 2001
  • Once refractive error of the eye was fully corrected. Polarization Test was used to investigate binocular vision function. As the results of phoria measurement of Korean adults for 53males and 59 females, orthophoria in 27.68%, esophoria in 12.50%, exophoria in 48.21%, verical phoria in 3.75%, esophoria(+verical phoria) in 2.68%, and exophoria(+vertical phoria) in 5.36%, respectively. Horizontal phoria is below $3{\Delta}$ mostly and verical phoria is below $1{\Delta}$.

  • PDF

A Study on Comparision of the Quantity of Phoria as Way to Separation of Binocular Fusion (양안융합의 분리 시간에 따른 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.331-337
    • /
    • 2014
  • Purpose: This is a comparative experimental study on the amount of phoria by the removal time of binocular fusion. In this study, three tests were used for phoria test like Howell test, Thorington test and developed 3D polarizing test. Methods: In this study, it was considered the removal time of binocular fusion for measuring phoria. The three methods were used for measuring quantity of phoria: Howell test, Thorington test and developed 3D Polarizing test. The measurements progressed quickly to avoid eye-strain. So we designed the test charts for marking 3D display modules and the apparatus inserted lenses, like Maddox lens and prism, which are compatible with three phoria tests. The phoria at the moment separation was measured when the binocular fusion was broken through the apparatus and the that at the stable separation was measured when activity of the separated two images like indicated box and figure on horizontal axis stopped. Results: There were statistically significant difference between quantity of phoria at moment separation and that at stable separation. Amount of phoria at moment separation was relatively larger than amount of that at stable separation. In result in exophoria, the quantity of phoria at moment separation was higher than that at stable separation, and in phoria measured by developed 3D polarizing test, it shows the similar results at two condition. Conclusions: For exophoria, the amount of phoria at moment separation of binocular fusion was relatively larger than that at stable separation. The amount of difference between phoria values at moment separation and that at stable separation was alike among three phoria tests. Usually in working, there is no distinction between moment separation and stable separation. But there were definitely the difference between two ways to separate binocular fusion. Therefore, it is need for writing on prescription test name for measuring phoria and condition of separation of binocular fusion.

A Comparative Study on Quantity of Phoria between New Phoria Measurement with 3D Display and Existing Methods (개발된 3D Display 장치를 이용한 사위검사법과 기존 사위검사법으로 측정한 사위량 비교에 관한 연구)

  • Kang, Seok Hyon;Hong, Hyungki
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • Purpose: This study compared the quantity of phoria for distance by new method with that by existing methods. Methods: For this study, it was selected to two existing phoria measurements, von Graefe and Maddox rod. And new method named "3D polarizing phoria measurement" was designed to measure the quantity of phoria using polarizing glasses and 3D display. Unlike existing measurement using polarized lens, newly considered method measured the quantity of phoria in condition removed perfect binocular fusion using field stop on apparatus and polarized lens. For using new method for distance, it was developed a phoria test chart. It supports three kinds of phoria measurements. Subjects were 12 (male 6, female 6). They had three phoria tests (1 sets) including new method. It was considered the effect of experimental order, so we tested all cases about experimental order. The number of cases was 6 sets, and the sample size in this experiment was 72 sets. For removing binocular fusion, lighting of the laboratory that was below 10 lx and the background color of phoria test chart was dark, RGB=(20, 20, 20). Results: Subjects were sorted into three groups. Samples with exophoria and orthophoria were 30 sets each, and those with esophoria were 12 sets. The quantity of phoria measured three tests differ from each other like "newmethod < von Graefe < Maddox rod", and there were statistically significant difference each other. Conclusions: This study has great significance in the sense that new method was the measurement with naturally removing binocular fusion without dizziness during the tests.

Research About Students' Horizontal Heterophoria in Near Distance with Maddox Rod (Maddox Rod를 사용한 대학생의 근거리 수평사위에 대한 고찰)

  • Choi, Kyong-Seo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.59-63
    • /
    • 2009
  • Purpose: To investigate the near horizontal heterophoria of the college students in their twenties on north Kyonggi Province. Methods: The all subjects had not experienced any ocular surgery and have no disease and their mean age is 22.9. As 122 subjects, they are 50 emmetropes and 72 ametropes. The ametropes are all myopia. After distance visual acuity correction with subjective and objective refraction test, evaluated their horizontal heterophoria with red maddox rod. Results: In maddox rod test, the subjects consist of orthophoria 4.9%, esophoria 9.8% and exophoria 85.3%. In the emmetropes orthophoria is 8%, esophoria is also 8% and exophoria is 84%. In the ametropes orthophoria is 2.8%, esophoria is 11.1% and exophoria is 86.1%. The mean size of horizontal heterophoria is esophoria 3.59PD (prism diopter), exophoria 7.04PD and in the emmetropes esophoria is 3.25PD, exophoria is 6.60PD. In the ametropes esophoria is 3.75PD and exophoria is 7.34PD. Conclusions: In the emmetropoes the orthophoria is more than in the ametropes and the esophoria and exophoria is more in the ametropes. But the differences between the heterophoria and emmetropia or ametropia were not significant (p>0.05). The mean size of heterophoria is higher in the ametropes than in the emmetropoes. The distribution range of heterophoria is wider in the male subjects than the female subjects.

  • PDF

Analysis of far & near distance of lateral phoria by various testing methods (검사 방법에 따른 원·근거리 수평사위의 분석)

  • Hong, Dong-Gyun;Jung, Han-Sub;Park, Sang-An
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.423-430
    • /
    • 2004
  • This Study on three different methods which are Von Graefe test, Maddox Rod test and Howell card test of measuring far and near lateral phoria investigated. It reviewed that 420 subjects aged from 15 to 35 years old. The result were as follows; 1. Using Von Graefe lateral phoria measurement, they were measured 6% for orthophoria, 62% for exophoria, 32% for esophoria at far distance. 2. Using Von Graefe lateral phoria measurement, they were measured 2% for orthophoria, 74% for exophoria, 24% for esophoria at near distance. 3. Using Maddox Rod lateral phoria measurement, they 59% for exophoria, 37% for esophoria at far distance. 4. Using Maddox Rod lateral phoria measurement, they 67% for exophoria, 30% for esophoria at near distance. 5. Using Howell card lateral phoria measurement, they 60% for exophoria, 32% for esophoria at far distance. 6. Using Howell card lateral phoria measurement, they 69% for exophoria, 27% for esophoria at near distance.

  • PDF

Study of Heterophoria Using Torrington Method in Third-year Student High School (토링톤법을 이용한 고 3 수험생들의 사위에 대한 고찰)

  • Ryu, Geun-Chang;Seong, Jeong-Sub
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.91-94
    • /
    • 2007
  • This research was investigated to find out the examinees' refractive problems within heterophoria using Torrington method. The number of subjects ware approximately 327 and subjects were sourced from the 12th grade student at high school in Kwang-Ju city. Result obtained shows 21.4% of emmetropia and 78.6% of ametropia. Most of refractive errors were myopia and due to it's condition, frequency of ametropia and emmetropia at the similar rate. However, one that consist of refractive problems, it's myopia contains 74.9% of heterophoria. Due to emmetropia, horizontal heterophoria have 45.7% of exophoria and 4.3% of esophoria. Myopia shows 11.4% of esophoria and 63.5% of exophoria. Hozizonda heterophoria shows 5.7% of emmetropia and myopia of 22.4%, than average of esophoria shows $4.3P{\Delta}$ and case of myopia, it was $3.4P{\Delta}$. Case of Exphoria, emmetropia have $8.8P{\Delta}$ and within myopia $8.0P{\Delta}$. Vertical heterophoria owns $2.2P{\Delta}$ within emmetropia and case of myopia $4.3P{\Delta}$ was shown. Which shows myopia result value higher than emmetropia.

  • PDF

Analysis of Induced Heterophoria Variations by Repeated Binocular Vision Examinations (반복된 양안시 검사로 유발된 사위도 변화 분석)

  • Leem, Hyun-Sung;Lee, Eun-Hee;Song, Yun-Young;Jung, Mi-A
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.281-286
    • /
    • 2018
  • The purpose of this study was to evaluate the degree of heterophoria variations according to visual fatigue induced by increasing number of examinations while repeating binocular vision examinations. Twenty - one adults in their twenties who had no heterotropia other eye disease or systemic disease underwent binocular vision examinations. As the examinations progressed, the degree of heterophoria increased in both orthophoria and heterophoria. When the distance examinations was repeated 5 times, orthophoria increased degree of $1.56{\Delta}$ heterophoria. and heterophoria increased degree of $1.63{\Delta}$ heterophoria. When the near examinations was repeated 5 times, orthophoria increased degree of $1.78{\Delta}$ heterophoria. and heterophoria increased degree of $2{\Delta}$ heterophoria.. As the number of examinations increased, the result gradually deviated from the normal range as visual fatigue increased. The degree of the variation is judged to be enough to make the wrong prescription in the clinic. In conclusion, it was found that the binocular vision examinations should be conducted more accurately and promptly.

Head Posture-Induced Phoria Deviation (머리 위치에 따른 사위도의 변화)

  • Ha, Eun-Mi;Son, Jeong-Sik;Moon, Byeong-Yeon;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.155-160
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate how phoria variations would vary with head positions, as well as to review the need to differentiate prism placement over either eye in a relation to the imbalance of the extraocular muscle. Methods: This study was carried out with 44 males (88 eyes) and 16 females (32 eyes) aged between 20 and 30. For all subjects, testings were performed using cover test, subjective refraction, phoria and vergence test. To analyze phoria variations comparatively for the head tilt test and the face turn test, phoria deviation were measured using the von Graefe. Results: For the phoria variation related with head tilt and face turn, a significant difference was observed in the group judged to be abnormal on the horizontal phoria of Morgan' norm (p<0.05); especially in patients who needed near prescription of Sheard's criterion, a higher variation was observed (p<0.05). The abnormal group was composed of patients who needed distance prescription of Sheard's criterion and ones who did not need the prescription, all of whom showed phoria variations, but the mean value was less than the near. Conclusions: With regard to the head tilt and face turn related phoria level, the patients who needed near horizontal prism prescription of Sheard's criterion showed a remarkably higher variation. Altogether, it is deemed to check whether extraocular muscles are ill-balanced in both eyes previously to determine the prism power on phoria level to the end that each of prism powers may be accurately determined.

A study on the distance and near horizontal phoria of the young people in Korea (한국 청년의 원거리와 근거리 수평사위에 관한 연구)

  • Kim, Hye-Dong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.251-255
    • /
    • 2004
  • Our research is about the measurement of the distance & near horizontal phoria by the Von Graefe test. The inspection was processed about normal 60 subjects(120eyes) aged from 20 to 30) years old by the subjective method of refraction. Among 120 eyes, the myopia is 64eyes(53%) and the emmetropia is 56eyes(47%). In the measurement of the distance horizontal phoria, we could know that the exophoria is 40%(24 subjects), the esophoria is 40%(24 subjects), and the orthophoria is 20%(12 subjects). In case of the near horizontal phoria, we could know that the exophoria is 65%(39 subjects), the esophoria is 23.3%(14 subjects), and the orthophoria is 11.7%(7 subjects).

  • PDF

A study on the measurement and tendency of heterophoria using Von Graefe test and Maddox rod test (프리즘 분리법과 마독스 로드 검사법을 이용한 사위측정과 경향 연구)

  • Oh, Hyun-Jin;Doo, Ha-Young;Oh, Seung-Jin
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.485-491
    • /
    • 2012
  • To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.