참고문헌
-
R. S. Aga, S. Yan, Y. Xie, S. Han and J. Z. Wu, 'Microwave surface resistance of
$HgBa_2CaCu_2O_{6+\delta}$ thin films,' Appl. Phys. Lett. Vol. 76, No. 12, pp. 1606-1608, (2000) https://doi.org/10.1063/1.126110 -
M. M. Mola, J. T. King, C. P. McRaven and S. Hill, 'Josephson plasma resonance in
$k-(BEDT-TTF)_2Cu(NCS)_2$ ,' Phys. Rev. B., Vol. 62, No. 9, pp. 5965-5970, (2000) https://doi.org/10.1103/PhysRevB.62.5965 -
H. Kitano, R. Matsuo, K. Miwa, A. Maeda, T. Takenobu, Y. Iwasa and T. Mitani, 'Evidence for insulating behavior in the electric conduction of
$(NH_3)K_3C_{60}$ systems,' Phys. Rev. Lett., Vol. 88, No. 9, pp. 096401-096404, (2002) https://doi.org/10.1103/PhysRevLett.88.096401 - J. D. Kokales, P. Fouriner, L. V. Mercaldo, V. V. Talanov, R. L. Greene and S. M. Anlage, 'Microwave electrodynamics of electron-doped cuprate superconductors,' Phys. Rev. Lett., Vol. 85, No. 17, pp. 3696-3699, (2000) https://doi.org/10.1103/PhysRevLett.85.3696
- E. A. Ash and G. Nicholls, 'Super-resolution aperture scanning microscope,' Nature, Vol. 237, pp. 510-512, (1972) https://doi.org/10.1038/237510a0
- T. P. Budka, S. D. Waclawik and G. M. Rebeiz, 'A coaxial 0.5-18GHz near electric field measurement system for planar microwave circuits using integrated probes,' IEEE Trans. Microwave Theory & Tech., Vol. 44, No. 12(1), pp. 2174-2184, (1996) https://doi.org/10.1109/22.556445
- S. Hong, J. Kim, W. Park and K. Lee, 'Improved surface imaging with a near-field scanning microwave microscope using a tunable resonator,' Appl. Phys. Lett., Vol. 80, No. 3, pp. 524-526, (2002) https://doi.org/10.1063/1.1435068
- M. Tabib-Azar, D. Akinwande, G. Ponchak and S. R. Clair, 'Novel physical sensors using evanescent microwave probes,' Rev. Sci. Instrum., Vol. 70, No. 8, pp. 3381-3386, (1999) https://doi.org/10.1063/1.1149923
- W. Park, J. Kim and K. Lee, 'Millimeter-wave scanning near-field microscope using a resonant waveguide probe,' Appl. Phys. Lett., Vol. 79, No. 16, pp. 2642-2644, (2001) https://doi.org/10.1063/1.1409944
- Grant R. Fowles, Introduction to Modern Optics, Dover, NY, (1975)
- David. K. Cheng, Field and Wave Electromagnetics, Prentice Hall, NY, (1989)
- D. M. Pozar, Microwave Engineering, Wiley, NY, (1990)
- J. D. Jackson, Classical Electrodynamics, John Wiley & Sons, NY, (1998)
- J. S. Hyde, R. R. Mett and J. R. Anderson, 'Cavities with axially uniform fields for use in electron paramagnetic resonance. III. re-entrant geometries,' Rev. Sci. Instrum., Vol. 73, No. 11, pp. 4003-4009, (2002) https://doi.org/10.1063/1.1510549
- M. Ohtsu, 'Near-field nano/atom optics and technology,' Springer-Verlag, Tokyo, (1998)
- A. F. Lann, M. Abu-teir, M. Golosovsky amd D. Davidov, 'A cryogenic microwave scanning near-field probe: application to study of high-Tc superconductors,' Rev. Sci. Instrum., Vol. 70, No. 11, pp. 4348-4355 (1999) https://doi.org/10.1063/1.1150078
- J. Kim, S. Kim, H. Yoo, J. Yang, H. Yoo, K. Yu, S. Kim and K. Lee, 'The study of near-field scanning microwave microscope for the nondestructive detection system,' Journal of the Korean Society for Nondestructive Testing, Vol. 24, No. 5, pp. 508-517, (2004)
- S. Kim, H. Yoo, A. Babajanyan, J. Kim and K. Lee, 'A study for a near-field microwave microscope using a tuning fork distance control system in liquid environment,' Journal of the Korean Society for Nondestructive Testing, Vol. 27, No. 4, pp. 339-347, (2007)