Abstract
The beam-column assembly in a ductile reinforced concrete (RC) frames subjected to seismic loading are generally controlled by shear and bond mechanisms, both of which exhibit poor hysteretic properties. Hence the response of joints is restricted essentially to the elastic domain. The usual earthquake resistant design philosophy of ductile frame buildings allows the beams to form plastic hinges adjacent to beam-column assembly. Increased strain in these plastic hinge regions affect on joint strain to be increased. Thus bond and shear joint strength are decreased. The research reported in this paper presents the test results of five RC beam-column assembly after developing plastic hinges in beams. Main parameter of the test Joints was the amount of the longitudinal tensile reinforcement of the beams. Test results indicted that the ductile capacity of joints increased as the longitudinal tensile reinforcement of the beams decreased. In addition, both the tensile strain of the longitudinal reinforcement bars in the joint and the ductile ratio of the beam-column assemblages increased due to the yielding of steel bars in the plastic hinge regions.
지진하중을 받는 철근콘크리트 접합부의 거동은 전단과 부착 메커니즘에 의해 결정된다. 하지만 전단과 부착은 반복하중에 매우 취약하기 때문에 접합부는 항상 탄성 영역 내에 있어야 한다. 내진 설계 기준에서는 보에 소성힌지를 발생시켜 기둥과 접합부는 탄성 상태를 유지하면서 보에서 에너지소산이 이루어지도록 하는 것을 원칙으로 한다. 하지만 접합부와 인접한 보에 소성힌지가 발생할 경우, 보에서 발생한 소성힌지에서의 철근 변형률이 접합부 철근의 변형에 영향을 미쳐 결국 접합부의 전단 및 부착강도를 떨어뜨리는 결과를 가져오게 된다. 본 논문에서는 보 인장 철근량을 변수로 한 다섯 개의 철근콘크리트 보-기둥 접합부를 제작하고 보에 소성힌지를 발생시킨 후 그 결과를 분석하였다. 실험 결과, 보 인장철근량이 적을수록 접합부의 연성은 증가하였다. 또한 소성힌지 영역의 철근이 항복함에 따라 접합부의 연성률이 증가하고 접합부의 보 부재축 방향 인장변형률도 증가하였다.