Abstract
The main objective of the paper is to investigate the static behavior of a prestressed concrete (PSC) girder that has been spliced with precast box segments. A 20 m long full-scale spliced PSC girder is fabricated and tested to compare its static performance against a monolithic girder. The monolithic girder has the same geometric and material properties with respect to the spliced girder. This includes infernal strain, deflections, neutral axis position, and crack patterns for both girders. The test also consists of monitoring relative displacements occurring across the joints. Both the horizontal displacement (gap) and vertical displacement (sliding) are measured throughout the loading procedure. All results have been compared to those obtained from the monolithic girder. It has been demonstrated that the spliced girder offers close behavior with respect to the monolithic girder up to the crack load. Both girders exhibits ductile flexural failure rather than abrupt shear failure at joints.
본 연구는 하나의 프리캐스트 거더를 분할하여 세그먼트로 각각 공장에서 제작하여 현장으로 운반한 후 포스트텐션 방식으로 체결하여 가설하는 분절공법으로 제작된 철도교 조립식 콘크리트 박스 거더의 정적 성능을 검증하고자 한다. 길이 20m의 실물 조립식 콘크리트 거더를 3등분으로 분절하여 제작한 후, 정적 성능 검증을 위해 같은 제원의 일체 거더와 동일한 조건에서 재하 실험을 수행하였다. 분절 거더 및 일체 거더에 대해 중앙 처짐, 단부 회전각, 균열 양상 등을 비교하였다. 또한 분절 거더의 접합부 거동을 모니터링하기 위해서 수직 상대 변위 및 수평 상대 변위를 최대 재하 하중까지 측정하였다. 분절 거더의 처짐은 육안으로 균열이 감지되는 균열하중 이상부터 일체 거더보다 상대적으로 크게 발생하고 있음을 알 수 있었다. 그러나 분절 거더는 균열하중에 도달하기 전까지 일체 거더와 동일한 거동을 보였다. 또한 분절부의 전단변형 여부를 조사하기 위한 수직 및 수평 상대 변위를 측정한 결과, 최종 재하 하중까지 전단에 의한 변형이 발생하지 않고 있음을 확인하였다. 또한 각 하중단계 별로 비교한 균열 양상은 분절 거더가 일체 거더와 같이 휨에 의한 사인장균열의 형태로 파괴가 진행되고 있음을 보였다.