• Title/Summary/Keyword: BJ-failure

Search Result 5, Processing Time 0.025 seconds

Evaluation of Structural Behavior of Reinforced Concrete Exterior Beam-Column Joints with High-Strength Concrete (고강도 콘크리트를 사용한 철근콘크리트 외부 보-기둥 접합부의 거동 평가)

  • Lee, Bum-Sik;Kim, Kyung-Duk;Kim, Sang-Woo;Kim, Kil-Hee;Lee, Jung-Yoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.72-81
    • /
    • 2014
  • This paper reports the test results of reinforced concrete exterior beam-column joints with high-strength concrete. The main parameters of eight specimens were joint failure modes, the compressive strength of concrete, and the head shapes of steel bars. All specimens were designed according to ACI 352R-02 design recommendations. Two types of failure modes were considered; J-failure and BJ-failure. The longitudinal steel bars were anchored by 90 degree standard hooks or headed reinforcement. Experimental results indicated that the current ACI design recommendation limited by the compressive strength of concrete somewhat underestimated the strength of beam-column joints with high-strength concrete. In the specimens showed joint shear failure, the strength of beam-column joints with headed bars was approximately 10 percent higher than that of joints with 90 degree standard hooks.

An Experimental Study on Shear Behavior of Internal Reinforced Concrete Beam-Column Assembly (철근콘크리트 보-기둥 내부 접합부의 전단 거동에 관한 실험적 연구)

  • Lee, Jung-Yoon;Kim, Jin-Young;Oh, Ki-Jong
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.441-448
    • /
    • 2007
  • The beam-column assembly in a ductile reinforced concrete (RC) frames subjected to seismic loading are generally controlled by shear and bond mechanisms, both of which exhibit poor hysteretic properties. Hence the response of joints is restricted essentially to the elastic domain. The usual earthquake resistant design philosophy of ductile frame buildings allows the beams to form plastic hinges adjacent to beam-column assembly. Increased strain in these plastic hinge regions affect on joint strain to be increased. Thus bond and shear joint strength are decreased. The research reported in this paper presents the test results of five RC beam-column assembly after developing plastic hinges in beams. Main parameter of the test Joints was the amount of the longitudinal tensile reinforcement of the beams. Test results indicted that the ductile capacity of joints increased as the longitudinal tensile reinforcement of the beams decreased. In addition, both the tensile strain of the longitudinal reinforcement bars in the joint and the ductile ratio of the beam-column assemblages increased due to the yielding of steel bars in the plastic hinge regions.

Coinical Study of Multiple Valve Replacement (심장 다판 치환술의 임상성적)

  • Kim, Sang-Hyeong;Kim, Ju-Hong;Na, Guk-Ju
    • Journal of Chest Surgery
    • /
    • v.27 no.10
    • /
    • pp.838-845
    • /
    • 1994
  • From April, 1982 to December, 1992, multiple valve replacement was performed in 100 patients. Mitral and aortic valve replacement were done in 86 patients, 9 underwent mitral and tricuspid valve replacement, 4 patients underwent triple valve replacement and 1 patient underwent aortic and tricuspid valve replacement. Of the valve implanted, 100 were St. Jude, 64 Duromedics, 19 Carpentier-Edwards, 13 Bj rk-Shiley, 6 Ionescu-Shiley, and 2 Medronics.The hospital mortality rate was 15%[15 patients] and the late mortality rate was 7%[7 patients], the mortality rate was high in early operative period but decreased with time[20% at 1986, 18.2% at 1987, 9.5% at 1988, 11.1% at 1989, 12.5% at 1990, 11.8% at 1991, 0% at 1992]. The causes of death were low cardiac output in 8, sudden death in 3, CHF in 3, bleeding in 2, cerebral thromboembolism in 1, leukemia in 1, multiorgan failure in 1 and so on. The actuarial survival rate excluding operative death was 73% at 10 years.

  • PDF

An Experimental Study on Shear Behaviorof Reinforced Concrete Beam-Column Joints (철근콘크리트 보-기둥 접합부의전단거동에 관한 실험적 연구)

  • Kim, Jin-Young;Oh, Ki-Jong;Lee, Jung-Yoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.105-108
    • /
    • 2006
  • Current ACI and AIJ guidelines only address the importance of the concrete strength and geometry of the joint. There are no significant attention paid to other variables. In addition, the current design code doesn't predict the ductility of the beam-column assemblies. The former researcher proposed the analytical model to predict the shear strength of the joint panel as well as the ductility of the beam-column assemblies in year 2004. In this study, the experiments to investigate shear behavior of reinforced concrete beam-column joints and to verify proposed model were carried out, based on the experimental results. As the formal researcher proposed, the factor K (K=0.5), the ductility of BJ-failure was predicted reasonably when the transverse reinforcement ratio exceeded 0.0186. However, the proposed equation showed a large discrepancies in the ductility estimating when transverse reinforcement ratio was below 0.0186.

  • PDF

Experimental Study on Seismic Performance of Beam-column Connections with High Strength Reinforcements (고장력 철근이 적용된 철근콘크리트 보-기둥 접합부 파괴모드에 대한 실험적 연구)

  • Kim, Dae-Hoon;Park, Aa-Ron;Lee, Kihak
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.61-68
    • /
    • 2016
  • Behavior of RC(Reinforced-concrete) beam-column connections has been subjected to the earthquake loading has been determined by shear and attachment mechanism. However, since the shear and attachment are very fragile for cycle loadings. Through occurring plastic hinges at the beam, the column and the connection should remain elastic condition and the beam should dissipate the energy from the earthquake. This study was investigate on the seismic performance of 6 RC beam - column connections built with the high strength reinforcements (700MPa) based on design and detailing requirements in the ACI 318-05 Provision and KCI-07 appendix II. This is aimed to evaluate the effect of the high-strength reinforcements as used the beam-column connection members. The main comparisons were the seismic performance of the connections affect the seismic performance in terms of strength, stiffness and ductility, joint shear stress-strain. A total of 6 beam-column specimens were built with a 1/2 scale and subjected to the cyclic loadings. Main design considerations were the area of the longitudinal reinforcements of the beam and details of the beam-column joint designed based on the seismic code. Cyclic test results are given and recommendations for the usage of high strength reinforcements for the seismic design is provided.