Abstract
We investigated the stability of the DLC film coated on 304 stainless steel substrate by Radio frequency assisted chemical vapor deposition method. Fracture and spallation behaviour of the coating was observed during micro-tensile test of the fil $m_strate composite. As the tensile deformation progressed, the cracks of the film were observed in the perpendicular direction to the tensile axis. Further deformation resulted in the plastic deformation with $45^{\circ}$ slip bands on the substrate surface. Spallation of the film occurred with the plastic deformation, which was initiated at the cracks of the film and was aligned along the slip directions. We found that both the cracking and the spallation behaviors are strongly dependent on the pre-treatment condition, such as Ar plasma pre-treatment. The spallation of the film was considerably suppressed in an optimized condition of the substrate cleaning by Ar glow discharge. We observed the improved stability with increasing duration of Ar plasma pre-treatment.nt.
미소인장시험을 통해 304 스테인리스 스틸 판재 위에 증착된 DLC 박막의 안정성을 평가하였다. 모재의 소성 변형과 함께 코팅 층의 손상이 발생하기 시작하는데, 작은 규모의 모재 변형 시에는 인장축의 수직방향으로 박막의 균열이 발생하지만, 모재의 슬립변형이 발생하기 시작하면 인장 축과 $45^{\circ}C$의 각도를 갖는 슬립 면을 따라 필름의 박리가 발생하였다. DLC박막의 박리면적으로부터 필름의 접착력을 평가할 수 있었으며, 필름의 합성 전에 실시하는 Ar 플라즈마 스퍼터링 세척시간이 길수록 그리고 세척시 기판에 인가되는 전압이 높을수록 필름의 접착력은 향상되었다. 이러한 변화는 스테인리스 스틸 모재와 Si 접합 층간의 계면특성이 향상되면, 필름의 전체 접착력을 증진시킬 수 있음을 보여주고 있다.