Abstract
To evaluate the applicability of the construction method involving infilling CFT columns by pumping-up, a trial construction was done using 6 actual size test samples. The 12.8m-high test samples were similar to a four-story building scale. The pumping-up level was controlled at 12m. The test used two types of high performance concrete with $450kgf/cm^2$ standard design strength, and a concrete pump which is used domestically. The pressure changes in pipes or pump as well as the changes in concrete characteristics were measured during construction. in order to evaluate applicability. After the concrete hardened, the column was dismantled. The filled state of the concrete, concrete strength distribution according to column height, etc., were checked to evaluate the quality of the concrete, From the results, some basic data which characterize the pumping-up pressure were suggested. Also, the strength of hardened concrete as well as the filled state were proven to be acceptable ranges.
콘크리트 충전강관(CFT) 기둥의 하부압입공법의 시공성을 평가하기 위해 6개의 실대규모 시험체에 대한 시험시공을 실시하였다. 시험체의 규모는 4개층 규모의 12.8m높이로 하여 콘크리트 압입 높이가 12m가 되도록 하였다. 사용된 콘크리트는 설계기준강도 $450kgf/cm^2$ 급의 고성능콘크리트이며 콘크리트 펌프는 국내에서 일반적인 시공시 사용하는 것을 채택하였다. 시공중 배관 및 펌프의 압력변화 특성, 콘크리트의 물성변화 등을 계측하여 시공성을 평가하였고 콘크리트가 굳은 후 기둥을 해체하여 콘크리트의 충전상태, 기둥높이에 따른 콘크리트 강도의 분포 등을 검사하여 콘크리트 품질을 확인하였다. 실험결과로부터 기본적인 압력특성 데이터를 제시하였으며 콘크리트의 충전성과 강도특성도 양호한 것을 확인할 수 있었다.