DOI QR코드

DOI QR Code

Analysis of New Air Control System in Clean Stocker

Clean Stocker내 새로운 방식의 기류제어에 관한 해석

  • Published : 2002.01.01

Abstract

Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. Since an important function of a stocker is to keep the contained material clean. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker, The airflow across the product prevent contamination from settling on the product. Up to now, stocker typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, In order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. Open ratios of exits need to be optimized for the same quantities of airflow in each exit. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and Blue Ridge Numerics FEM software, CFDesign, was used fur simulating airflow in stocker. As a result, Open ratios of exits important to provide constant clean airflow can be obtained by the analysis of static pressure regain and was verified by simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

Keywords

References

  1. 이재헌, 1998, '다수의 출구를 가지는 크린룸 내부의 기류분포에 관한 연구,' 공기조화냉동공학논문집, 제17권, 제4호, pp. 418-425
  2. Eric, C., Duane, P., 1996, 'Standard Stocker Environmental Characterization Method,' Technology Transfer #96103192A-ENG. SEMATECH, pp. 2-11
  3. DAIFUKU(株), 2001, Clean Stocker 자료
  4. Fundamentals, Asharae. 1989, ashrae Hand Book
  5. 井上宇市, 1998, '空氣調和 HANDBOOK,' pp. 385-396
  6. Blue Ridge, 1998, Blue Ridge Numerics Software Reference Manuals
  7. 이광수, 1998, 'Clean Room내 기류의 제어 및 해석,' 공기조화냉동공학논문집, 제17권, 제3호, pp. 217-223
  8. 이재헌, 박명식, 1993, '부분적인 필터교체에 따른 청정실내부의 유동특성,' 대한기계학회논문집, 제14권, 제2호, pp. 2110-2121
  9. 오명도, 임학규, 배귀남, 1990, '초청정 클린룸 난류유동장내에서의 오염입자 비정상 전파거동에 관한 연구,' 대한기계학회논문집, 제14권, 제2호, pp. 430-439
  10. Ron B., Patricia B., 1995, 'Summary of Material Logistics in Semiconductor Manufacturing, Technology Transfer #95052811A-ENG SEMATECH, pp. 14-20