온도조절 모드에 따른 차량용 공조장치 내부 유동특성

Internal flow characteristics inside an automobile HVAC according to temperature operation mode

  • 지호성 (포항공과대학교 기계공학과) ;
  • 이상준 (포항공과대학교 기계공학과)
  • 발행 : 2008.03.26

초록

Air flow of inside automobile HVAC module has been visualized using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera(2K x 2K), optics and a synchronizer. A real automobile HVAC module was used directly with slight modification for clear optical windows. Some parts of the HVAC module casing were replaced with transparent windows for capturing flow images with laser light sheet beam illumination. Time-averaged velocity field were measured in three temperature control modes. Flow characteristics of the air-conditioned air flow in the automobile HVAC system were evaluated.

키워드