• 제목/요약/키워드: 온도격판

검색결과 6건 처리시간 0.021초

온도조절 격판 변화에 따른 차량용 HVAC 내부 유동의 PIV속도장 측정 연구 (PIV Measurement of Flow Inside an Automotive HVAC Module with Varying Temperature Baffle)

  • 지호성;이상준
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.27-33
    • /
    • 2008
  • Air flow inside an automotive HVAC module has been investigated using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser (125 mJ), a high-resolution CCD camera (2K$\times$2K), optics and a synchronizer. A real automotive HVAC module was used directly under real operating condition. Some casing parts of the HVAC module were replaced with transparent windows for capturing clear flow images with laser light sheet beam illumination. Time-averaged velocity fields were obtained for two different temperature control modes. Flow characteristics of the air-conditioned air flow inside the automotive HVAC system for the two temperature baffle conditions were evaluated.

유공성 수평격판을 가진 열원이 있는 밀폐공간내의 온도분포 특성 (Characteristices of Temperature Distribution in a Closed Space with Heat Source and Porous Horizontal Partition)

  • 박찬수;조대환;전철균
    • 한국해양공학회지
    • /
    • 제13권3B호
    • /
    • pp.29-37
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-${\epsilon}$ model was carried out. In the present study, the marine engine room is separated to two floors with porus horizontal partition and considered as a closed space with a heat source and forced ventilation ducts. The porosity of horizontal partition is found to be important. For the engine room with 2 supply ports & 2 exhaust ports, the increasing of the porosity of horizontal partition is effective to reduce the recirculation flow zone in the second floor. When the engine room is ventilated with three supply air ports & one exhaust port, the increasing of the porosity of horizontal partition is effective to reduce the recirculating flow zone in the exhaust air area, but there is a possibility of local extreme heating at the lower side of engine near bottom.

  • PDF

격판분리 축열조의 히트펌프 성능개선 효과 (Effect of heat pump performance improvement by use of thermal tank with temperature seperation plate)

  • 문종필;이성현;권진경;강연구;이수장
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.80.1-80.1
    • /
    • 2011
  • This study was carried out in order to estimate the effect of heat pump performance by use of thermal tank with 3 seperation plates which were able to divide thermal tank into 3 chambers that have different temperatures levels. For testing the effect of developed thermal tank which was installed for supplying the heat to the paprika greenhouse in Jinju city. The volume of thermal storage tank was designed for $110m^3$ which was able to cover 30% of heating capacity. The temperature difference was 3 degree Celcius between high temperature and low temperature when only heating circulation was made from heat pump to thermal tank. but 5.5 degree Celcius difference was made when heating circulation of heat pump to thermal thank and hot water supplying circulation of thermal tank to greenhouse was done simultaneously. As a result of this study showed that COP of heat pump was increased by 15% or more than that of using normal thermal tank because heat pump was able to take 3 ~ 5 degree Celcius lower thermal thank water constantly.

  • PDF

온도조절 모드에 따른 차량용 공조장치 내부 유동특성 (Internal flow characteristics inside an automobile HVAC according to temperature operation mode)

  • 지호성;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.687-688
    • /
    • 2008
  • Air flow of inside automobile HVAC module has been visualized using a high-resolution PIV technique with varying the temperature operation mode. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera(2K x 2K), optics and a synchronizer. A real automobile HVAC module was used directly with slight modification for clear optical windows. Some parts of the HVAC module casing were replaced with transparent windows for capturing flow images with laser light sheet beam illumination. Time-averaged velocity field were measured in three temperature control modes. Flow characteristics of the air-conditioned air flow in the automobile HVAC system were evaluated.

  • PDF

가압 경수로에서 생성된 시멘트 고화체로부터 Cs-137의 용출 현상의 실험적 연구 (Experimental Study of Leaching Phenomena of Cs-137 From a Cement Matrix Generated at PWR Plant)

  • 도정열;이건재
    • Journal of Radiation Protection and Research
    • /
    • 제11권2호
    • /
    • pp.91-103
    • /
    • 1986
  • 가압 경수로형 원자로에서 발생하는 증발기 저부 폐액에서의 Cs-137의 용출에 대한 실험을 수행하였다. IAEA에 의해 제안된 용출실험 방법에 근거를 두고, ANS 방법의 일부를 채용하였다. 용출에 영향을 미치는 여러 인자들로서, 시료채취방법, 양생온도, 양생기간, 용출액 온도, Vermiculite 첨가와 체적 대 표면적비 등이 고려되었다. 준 무한 격판(Semi-infinite Slab)에 대한 확산 모델은 4주간 경화된 시료의 실험치와 좋은 일치를 보이고 있다. 4주간 $25^{\circ}C$에서 양생된 시료의 표면적 확산 계수는 $1.20{\sim}1.47{\times}10^{-11}cm^2/sec$가 됨을 확인했으며, 이 계수에 의해 Cs-137의 장기 용출을 예측을 유한 격판 근사(Finite-slab Approximation) 방법을 이용하여 수행하였다. 또한, 계산 결과로부터 Cs-137은 용출 개시후 약 25년이 되면 초기량의 0.66%인 최대치가 되며 100년 후에는 약 0.25%가 잔류한다.

  • PDF

PIV기법을 이용한 차량용 공조 시스템 내부유동에 대한 실험적 연구 (An experimental analysis of the fluid flow in an automobile HVAC system using a PIV technique)

  • 지호성;김보람;이상준
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.92-96
    • /
    • 2007
  • Internal flow characteristics for an automobile HVAC have been investigated using a high-resolution PIV technique. The PIV system consists of a 2-head Nd:YAG laser(125 mJ), a high-resolution CCD camera($2K\;{\times}\;2K$), optics and a synchronizer. An automobile HVAC module was used directly. Only the casing was remodeled transparently for capturing flow image and laser sheet beam illumination. Time-averaged velocity field were measured in three temperature control mode. For three temperature control modes, the internal flow characteristics for an automobile HVAC system were evaluated from PIV results..

  • PDF