화력발전용 가스재열기 Sector Plate의 유한요소 해석

Finite Element Analysis of Gas-Gas Heater Sector Plate in Thermal Power Plant

  • 황석환 (두산중공업(주) 기술연구원) ;
  • 이후광 (두산중공업(주) 기술연구원) ;
  • 최재승 (두산중공업(주) 기술연구원)
  • 발행 : 2001.06.27

초록

Today's industrialized plants are required to reduce SOx emitted from stacks at factories, utility power stations, etc. For this purpose, flue gas desulfurization (FGD) system is installed and gas-gas heater (GGH) is used to play a vital role to reheat the wet treated gas from FGD. The sector plates are located at cold and hot sides of gas gas heater. They serve as sealing to prevent mixing treated and untreated gases. Therefore, the deformation of the sector plate due to its dead weight and gas pressure should be considered as major factor for the sector plate design.

키워드