• Title/Summary/Keyword: zeta potential

Search Result 609, Processing Time 0.024 seconds

Improving the Initial Effluent Turbidity by Polyaluminium Chloride(PAC) Coating in Rapid Sand Filtration (급속모래여과에서 PAC 피복에 의한 초기 유출수의 탁도 개선)

  • Yoon, Tae-Han;Kim, Woo-Hang
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.3
    • /
    • pp.253-260
    • /
    • 2002
  • The purpose of this research was to describe the mechanisms and prevention of initial degradation in turbidity of the sand filter effluent. The method used was by adding a coagulant (PAC) to the sand filter after backwashing as a means of reducing turbidity. It was found that adding 80 mg/L of PAC solution to the sand filter was very effective in improving the initial effluent turbidity. A turbidity removal efficiency of 99 % was observed in the initial term period as compared to a 70% efficiency without PAC addition. The PAC solution added to the sand filter resulted in high aluminum concentration at the upper layer as compared with the bottom layer of the sand filter column. A change in the zeta potential to a strong positive-ions at upper layer was observed at this time but only a small change was obtained at the bottom. This result showed that the zeta potential of the sand was changed to positive with PAC coating. The effect of pH on zeta potential with PAC addition was also investigated. Zeta potential was greatly changed to positive-ion at pH 4~6. A series of experiments was then conducted in this study to optimize the pH of the PAC solution to be added to the sand filter after backwashing. The removal efficiency of turbidity was found to be highest at pH 5. This result suggested that hydrolyzed aluminium species attached to the surface of the sand enhanced the removal of turbidity of the effluent.

Removal of Red Tide Organisms -2. Flocculation of Red Tide Organisms by Using Loess- (적조생물의 구제 -2. 황토에 의한 적조생물의 응집제거-)

  • KIM Sung-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.5
    • /
    • pp.455-462
    • /
    • 2000
  • The objective of this study was to examine the physicochemical characteristics of coagulation reaction between loess and red tide organisms (RTO) and its feasibility, in developing a technology for the removal of RTO bloom in coastal sea. The physicochemical characteristics of loess were examined for a particle size distribution, surface characteristics by scanning electron microscope, zeta potential, and alkalinity and pH variations in sea water. Two kinds of RTO that were used in this study, Cylindrothen closterium and Skeietonema costatum, were sampled in Masan bay and were cultured in laboratory. Coagulation experiments were conducted using various concentrations of loess, RTO, and a jar tester. The supernatant and RTO culture solution were analyzed for pH, alkalinity, RTO cell number. A negative zeta potential of loess increased with increasing pH at $10^(-3)M$ NaCl solution and had -71.3 mV at pH 9.36. Loess had a positive zeta potential of +1,8 mV at pH 1.98, which resulted in a characteristic of material having an amphoteric surface charge. In NaCl and $CaCl_2$, solutions, loess had a decreasing negative zeta potential with increasing $Na^+\;and\;Ca^(+2)$ ion concentration and then didn't result in a charge reversal due to not occurring specific adsorption for $Na^+$ ion while resulted in a charge reversal due to occurring specific adsorption for $Ca^(+2)$ ion. In sea water, loess and RTO showed the similar zeta potential values of -112,1 and -9.2 mV, respectively and sea sand powder showed the highest zeta potential value of -25.7 mV in the clays. EDLs (electrical double-layers) of loess and RTO were extremely compressed due to high concentration of salts included in sea water, As a result, there didn't almost exist EDL repulsive force between loess and RTO approaching each other and then LVDW (London-yan der Waals) attractive force was always larger than EDL repulsive force to easily form a floe. Removal rates of RTO exponentially increased with increasing a loess concentration. The removal rates steeply increased until $800 mg/l$ of loess, and reached $100{\%}$ at 6,400 mg/l of loess. Removal rates of RTO exponentially increased with increasing a G-value. This indicated that mixing (i.e., collision among particles) was very important for a coagulation reaction. Loess showed the highest RTO removal rates in the clays.

  • PDF

Characteristics of oyster shell using zeta potential (제타 전위에 의한 참굴 패각의 특성연구)

  • Lee, Seung-Woo;Shin, Na-Young;Choi, Cheong-Song
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.890-893
    • /
    • 2001
  • Zeta potential measurement not only can provide surface information on colloidal biomaterials but more importantly can be used in bioprocess control and products quality control. In this study, zeta potentials for intracrystalline proteins of each layers from oyster shell prepared in 1mM NaCl at different pH were measured. Also, in forming calcite crystals with intracrystalline proteins as an additive extracted from oyster shell, the zeta potentials were measured. These studies were performed to verify the primary role of intracrystalline proteins in controlling the formation, morphological development and crystallography of the biocomposite.

  • PDF

The Theoretical Investigation on the Stability of Solid/Liquid Dispersion (고/액간 계면에 있어서 분산의 안정성에 관한 이론적 고찰)

  • Kim, Tae-Young;Cho, Kyoung-Haeng;Nam, Kie-Dae
    • Journal of the Korean Applied Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 1995
  • In this outline, the stability of solid/liquid dispersion was theoretically investigated the matter from all angles by using the modified DLVO theory. The stability was handled various considerations such as a production and characteristics of electrical double layer, total interaction$(V_T)$ that consisting of attractive force$(V_A)$ and repulsion$(V_R)$. coagulation, the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ etc. It was possible for us to examine with the stability ratio(W), critical flocculation concentration (cfc) and zeta potential$(\zeta)$ that may estimation of stability of solid/liquid dispersion experimentally.

Comparison of Electrocoagulation and Chemical Coagulation in Removal on Water Treatment (정수처리에서 전기응집과 화학응집의 처리효율 비교)

  • Han, Moo-Young;Song, Jae-Min;Park, Sang-Cheol
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.689-695
    • /
    • 2004
  • Electrocoagulation has been suggested as a promising alternative to conventional coagulation. The process is characterized by reduced sludge production, no requirement for chemical use, and ease of operation. However, this coagulation has scarcely been studied in water purifying process. This study was performed several batch experiments to compare turbidity removal between electrocoagulation and chemical coagulation. In addition, characteristics of floe were evaluated with zeta potential and particle size distributions. Electrocoagulation showed a relatively higher removal of turbidity (approximately 5%) with the same aluminum amount than conventional chemical coagulation. In addition, turbidity removal by electrocoagulation was less sensitive to pH and was greater for more extensive pH range than chemical coagulation. The results of zeta potential and floc size distributions illustrated that electrocoagulation provided the preferable conditions for coagulation such as zeta potential close to zero millivolt and increased portions of particles in the range of 40 and $100{\mu}m$.

Effect of Recycling Time on Stability of Colloidal Silica Slurry and Removal Rate in Silicon Wafer Polishing (연마 Recycling 시간에 따른 콜로이드 실리카 슬러리의 안정성 및 연마속도)

  • Choi, Eun-Suck;Bae, So-Ik
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.2 s.297
    • /
    • pp.98-102
    • /
    • 2007
  • The stability of slurry and removal rate during recycling of colloidal silica slurry was evaluated in silicon wafer polishing. The particle size distribution, pH, and zeta potential were measured to investigate the stability of colloidal silica. Large particles appeared as recycling time increased while average size of slurry did not change. Large particles were identified by EDS(energy dispersive spectrometer) as foreign substances from pad or abraded silicon flakes during polishing. As the recycling time increased, pH of slurry decreased and removal rate of silicon reduced but zeta potential decreased inversely. Hence, it could be mentioned that decrease of removal rate is related to consumption of $OH^-$ ions during recycling. Attention should be given to the control of pH of slurry during polishing.

Studies on the Adsorption Modeling of Cationic Heavy Metals(Pb, Cd) by the Surface Complexation Model (Surface Complexation Model을 이용한 양이온 중금속(Pb, Cd) 흡착반응의 모델화 연구)

  • 신용일;박상원
    • Journal of Environmental Science International
    • /
    • v.8 no.2
    • /
    • pp.211-219
    • /
    • 1999
  • Surface complexation models(SCMs) have been performed to predict metal ion adsorption behavior onto the mineral surface. Application of SCMs, however, requires a self-consistent approach to determine model parameter values. In this paper, in order to determine the metal ion adsorption parameters for the triple layer model(TLM) version of the SCM, we used the zeta potential data for Zeolite and Kaolinite, and the metal ion adsorption data for Pb(II) and Cd(II). Fitting parameters determined for the modeling were as follows ; total site concentration, site density, specific surface area, surface acidity constants, etc. Zeta potential as a new approach other than the acidic-alkalimetric titration method was adopted for simulation of adsorption phenomena. Some fitting parameters were determined by the trial and error method. Modeling approach was successful in quantitatively simulating adsorption behavior under various geochemical conditions.

  • PDF

Effects of Polyelectrolyte Dosage, Kaoline Particles and pH on Flocculation of Humic Acid by Catonic Polyelectrolytes

  • Kam, Sang-Kyu;Kim, Dae-Kyoung;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.12 no.8
    • /
    • pp.861-870
    • /
    • 2003
  • Using a simple continuous optical technique, coupled with measurements of zeta potential, the effects of polyelectrolyte dosage, kaoline particles and pH on flocculation of humic acid by several cationic polyelectrolytes, have been examined. The charge density of a polyelectolyte is important in determining the optimum dosage and in the removal of humic acid. The optimum dosage is less for the polyelectrolytes of higher charge density and is the same regardless of the presence of kaoline particles of different turbidity. At the dosage, the removal of humic acid is higher for the polyelectrolytes of higher charge density and the zeta potential of humic acid approaches to near zero, With increasing pH of humic acid, the optimum dosage increases and the flocculation index value obtained at the dosage decreases in the following pH 7 > pH 5 > pH 9, regardless of polyelectrolytes.

Zeta-potential in CMP process of sapphire wafer on poly-urethane pad (폴리우레탄 패드를 이용한 기계-화학 연마공정에서 파이어 웨이퍼 표면 전위)

  • Hwang, Sung-Won;Shin, Gwi-Su;Kim, Keun-Joo;Suh, Nam-Sup
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1816-1821
    • /
    • 2003
  • The sapphire wafer for blue light emitting device was manufactured by the implementation of the chemical and mechanical polishing process. The surface polishing of crystalline sapphire wafer was characterized by zeta potential measurement. The reduction process with the alkali slurry provides the surface chemical reaction with sapphire atoms. The poly-urethane pad also provides the frictional force to take out the chemically-reacted surface layers. The surface roughness was measured by the atomic force microscope and the crystalline quality was characterized by the double crystal X -ray diffraction analysis.

  • PDF

Relationship between Electroosmotic Drainage and Zeta Potential of Clayey Soils (점성토의 전기삼투 배수와 Zeta Potential의 상관성)

  • 김수삼;한상재;임성철
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.69-77
    • /
    • 2000
  • 본 연구에서는 전기삼투 배수와 제타포텐셜과 상관성을 규명하고자 하였다. 실험으로 직경 10cm, 길이 16cm의 원형 압밀시료에 일정 전압경사법으로 1V/cm의 직류접압을 가하여 0, 500, 3000 ppm의 납농도와 0, 230, 2300, 23000 ppm의 염분농도에서 각각 12일 과 14일 동안 전지삼투 배수량을 측정하였고, 같은 농도에서 kaolinite 현탁액의 제타포텐셜을 pH2부터 14범위에서 측정하였다. 실험결과 제타포텐셜은 전해질 농도와 pH 변화에 의존적이고, 전기삼투 투수계수와 비례관계가 있음을 확인할 수 있었다. 제타포텐셜에 따른 전기삼투 배수량과 비교한 결과, 전해질 농도가 낮을수록 제타포텐셜은 음의 값은 크고, 전기삼투 배수량도 더 증가하였다.

  • PDF