• 제목/요약/키워드: zero-loss

검색결과 526건 처리시간 0.03초

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

공진형 듀얼컨버터의 동작특성에 관한 고찰 (A Study of the Operation Characteristics of the Resonant Dual Converters)

  • 양승학
    • 전력전자학회논문지
    • /
    • 제2권4호
    • /
    • pp.1-10
    • /
    • 1997
  • 공진형 듀얼 컨버터는 스위칭손실이 낮은 고주파 스위칭으로 전력변환을 실현할 수 있는 회로방식으로서 주목받고 있다. 본 논문에서는 유도전동기를 부하로 하여 구동과 회생운전이 가능한 쌍방향 공진형 전력변환 시스템을 구축하고, 이 시스템의 실제적인 적용을 위하여 일련의 실험을 통해 제작시스템의 운전특성을 검증한다. 고찰부분으로서는 입출력특성, 공진부특성, 주소자와 클램프소자에서의 턴 오프특성 및 영전압특성에 대한 실험결과를 대상으로 한다. 본 연구에서는 관측된 파형들을 검증함으로서 제작시스템에 있어서의 문제점을 고찰하고 금후의 연구를 위한 제안을 제시하고자 한다.

  • PDF

액티브 보조 공진 스너버를 이용한 ZVT-PWM AC-DC 컨버터의 실험적 고찰 (The Experimental Consideration of ZVT-PWM AC-DC Converter using Active Auxiliary Resonant Snubber)

  • 서기영;문상필;김주용;박진민
    • 조명전기설비학회논문지
    • /
    • 제18권2호
    • /
    • pp.75-82
    • /
    • 2004
  • 본 논문에서 액티브 스너버 회로를 가진 영전압 변환 펄스 폭 변조(ZVT-PWM) 컨버터를 제안하였다. 제안된 컨버터는 경부하 상태에서도 동작하며, 영전압 스위칭과 영전류 스위칭 부근에서 온-오프 되며, 주 스위치와 주다이오드에 전압과 전류의 스트레스가 추가적으로 발생하지 않는다. 그리고 보조 스위치와 보조 다이오드의 전압과 전류 허용 레벨을 제시하였다. 제안된 750[W], 80[KHz] PWM 부스터 컨버터는 전 출력 전력에서 소프트 스위칭 컨버터를 적용하여 실행한 결과 주 스위치에서의 손실은 하드 스위칭과 비교해서 약 27[%], 전체 회로 손실은 약 36[%] 저감되었으며, 전체 효율은 기존의 컨버터보다 보다 6{%] 정도 향상됨을 확인하였다.

무전극 램프 구동용 영전압 스위칭 고주파 인버터에 관한 연구 (Zero-Voltage-Switching High Frequency Inverter for Electrodeless Fluorescent Lamp)

  • 박동현;김희준;조기연;계문호
    • 전자공학회논문지S
    • /
    • 제35S권8호
    • /
    • pp.113-119
    • /
    • 1998
  • 무전극 램프의 점등은 램프 양단에 고주파를 갖는 고전압을 인가해야 한다. 종래의 무전극 램프의 구동 회로로 선형 증폭기가 이용되어져 왔으나, 낮은 에너지 변환 효율로 인해 PWM 스위칭 방식의 인버터로 교체되고 있다. 그러나 고주파 스위칭시 인버터의 스위칭 소자에서 스위칭 손실의 증가 및 노이즈 발생의 문제로 인해 PWM 인버터는 고주파 동작이 제한된다. 이러한 문제점을 해결하기 위해 영전압 스위칭 기술을 PWM 인버터에 적용하여 고주파 스위칭이 가능하게 하고, 또한 스위칭 손실과 노이즈 발생을 줄일 수 있다. 본 논문에서는 무전극 램프 구동회로로 영전압 스위칭 고주파 인버터에 대하여 동작 해석과 설계 지침 제시하였다. 또한, 실험을 통하여 해석된 결과의 타당성을 확인하였다.

  • PDF

Optimized Low-Switching-Loss PWM and Neutral-Point Balance Control Strategy of Three-Level NPC Inverters

  • Xu, Shi-Zhou;Wang, Chun-Jie;Han, Tian-Cheng;Li, Xue-Ping;Zhu, Xiang-Yu
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.702-713
    • /
    • 2018
  • Power loss reduction and total harmonic distortion(THD) minimization are two important goals of improving three-level inverters. In this paper, an optimized pulse width modulation (PWM) strategy that can reduce switching losses and balance the neutral point with an optional THD of three-level neutral-point-clamped inverters is proposed. An analysis of the two-level discontinuous PWM (DPWM) strategy indicates that the optimal goal of the proposed PWM strategy is to reduce switching losses to a minimum without increasing the THD compared to that of traditional SVPWMs. Thus, the analysis of the two-level DPWM strategy is introduced. Through the rational allocation of the zero vector, only two-phase switching devices are active in each sector, and their switching losses can be reduced by one-third compared with those of traditional PWM strategies. A detailed analysis of the impact of small vectors, which correspond to different zero vectors, on the neutral-point potential is conducted, and a hysteresis control method is proposed to balance the neutral point. This method is simple, does not judge the direction of midpoint currents, and can adjust the switching times of devices and the fluctuation of the neutral-point potential by changing the hysteresis loop width. Simulation and experimental results prove the effectiveness and feasibility of the proposed strategy.

Operating characteristics of a superconducting DC circuit breaker connected to a reactor using PSCAD/EMTDC simulation

  • Kim, Geon-woong;Jeong, Ji-sol;Park, Sang-yong;Choi, Hyo-sang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.51-54
    • /
    • 2021
  • The DC system has less power loss compared to the AC system because there is no influence of frequency and dielectric loss. However, the zero-crossing point of the current is not detected in the event of a short circuit fault, and it is difficult to interruption due to the large fault current that occurs during the opening, so the reliability of the DC breaker is required. As a solution to this, an LC resonance DC circuit breaker combined a superconducting element has been proposed. This is a method of limiting the fault current, which rises rapidly in case of a short circuit fault, with the quench resistance of the superconducting element, and interruption the fault current passing through the zero-crossing point through LC resonance. The superconducting current limiting element combined to the DC circuit breaker plays an important role in reducing the electrical burden of the circuit breaker. However, at the beginning of a short circuit fault, superconducting devices also have a large electrical burden due to large fault currents, which can destroy the element. In this paper, the reactor is connected to the source side of the circuit using PSCAD/EMTDC. After that, the change of the fault current according to the reactor capacity and the electrical burden of the superconducting element were confirmed through simulation. As a result, it was confirmed that the interruption time was delayed as the capacity of the reactor connected to the source side increased, but peak of the fault current decreased, the zero-crossing point generation time was shortened, and the electrical burden of the superconducting element decreased.

트위스트 피치를 고려한 Bi-2223 선재 제작과 AC 손실 측정 및 분석 (Fabrication, AC Loss Measurement and Analysis of Bi-2223 Conductors with Respect to Various Twist Pitch)

  • 장미혜;추용;임준형;주진호;고태국
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.589-595
    • /
    • 2000
  • In this papre, AC losses of Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist and different twist pitch(8, 10, 13, 30, 50, 70 mn). The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-probe method. And the AC loss measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the critical current is larger non-twist than twisted filament. And, the AC loss by Norris equation is higher non-twisted tape than 13mm twisted tape. Also, it is confirmed that of AC loss of tape having non-twist pitch larger than those having differnet twist pitch.

  • PDF

마그네틱 기어의 영구자석 부착방법에 따른 영구자석 와전류손실 분석 (Analysis of Permanent Magnet Eddy Current Loss by Permanent Magnet Attaching Method of Magnetic Gears)

  • 박의종;김성진;정상용;김용재
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.911-915
    • /
    • 2017
  • Recently, there has been an increasing interest in the non-contact power transmission method of magnetic gears. Since there is no mechanical contact, noise caused by friction can be reduced, and even if a sudden large force is applied, the impact of the gear is close to zero. Further, since the power is transmitted by the magnetic flux, it has high reliability. However, there is a problem that a loss due to a magnetic field due to use of a magnetic flux. The loss caused by the magnetic field of the magnetic gear is a joule loss called eddy current loss. In addition, the eddy current loss in the magnetic gear largely occurs in the permanent magnet, but it is a fatal loss to the permanent magnet which is vulnerable to heat. Particularly, magnetic gears requiring high torque density use NdFeB series permanent magnets, and this permanent magnets have a characteristic in which the magnetic force decreases as temperature increases. Therefore, in this paper, the eddy current loss of the permanent magnet according to the permanent magnet attaching method is analyzed in order to reduce the eddy current loss of the permanent magnet. We have proposed a structure that can reduce the eddy current loss through the analysis and show the effect of reducing the loss of the proposed structure.

A Study of Characteristic of Electrical-magnetic and Neutron Diffraction of Long-wire High-superconductor for Reducing Energy Losses

  • Jang, Mi-Hye
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권6호
    • /
    • pp.265-272
    • /
    • 2008
  • In this paper, AC losses of long wire Bi-2223 tapes with different twist pitch of superconducting core were fabricated, measured and analyzed. These samples produced by a powder-in-tube method are multi-filamentary tape with Ag matrix. Also, it's produced by non-twist. The critical current measurement was carried out under the environment in Liquid nitrogen and in zero field by 4-prob method. And the Magnetic measurement was carried out under the environment of applied time-varying transport current by transport method. From experiment, the susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O).

결합 인덕터를 적용한 고효율 3레벨 컨버터 (A New Zero-Voltage Switching Three-Level Converter with Reduced Rectifier Voltage Stress)

  • 김건우;한정규;문건우
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.406-410
    • /
    • 2019
  • Three-level (3L) DC-DC converters are appropriate for high-input-voltage applications. Although the voltage stress of TL converter switches can be reduced to half of the input voltage, the primary side has a large circulating current, which degrades efficiency. In this study, a dual half-bridge cascaded TL converter is presented to reduce this circulating current and thus decrease the conduction loss of the primary circuit. Moreover, the proposed converter can reduce the voltage stress of rectifier diodes, thereby reducing their conduction loss. Therefore, efficiency can be improved by reducing the conduction loss of the primary circuit and rectifier diodes.