• Title/Summary/Keyword: zero-failure test

Search Result 47, Processing Time 0.021 seconds

Study for the Reliability Evaluation of a Volute Pump (벌류트 펌프의 신뢰성 평가에 관한 연구)

  • Jung, Dong Soo;Lee, Yong Bum;Kang, Bo Sik
    • Journal of Drive and Control
    • /
    • v.15 no.4
    • /
    • pp.23-29
    • /
    • 2018
  • The objective of this paper is to evaluate the reliability of a volute pump and presents test results through performance and life tests. The performance and life test methods were presented by analyzing the failure modes of the volute pump. Zero failure test time was calculated to evaluate the reliability of the volute pump and then, the test was performed under accelerated conditions. The test was also carried out to check the failure modes of the field conditions. This study can be provided to improve the product reliability through failure analysis of the volute pump. And failure cause of typical failure case has been investigated and improvement design has been presented. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the volute pump.

Statistical Design of Two-Stage Reliability Demonstration Tests (2단계 신뢰성 실증시험의 통계적 설계)

  • Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.39 no.2
    • /
    • pp.313-319
    • /
    • 2011
  • In design verification and process validation stages, reliability demonstration tests(RDT's) are common practice in industry, A new two-stage RDT that is known to be more efficient than a corresponding single-stage one in terms of expected test duration for Weibull distribution is proposed. Zero or one failure two-stage plans to minimize expected test duration under Type I and hybrid censoring subject to satisfying consumer's risk at a specified reliability target are developed and a numerical example is provided to illustrate the proposed two-stage RDT plans and compared with other one- and two-stage plans.

Analysis of High Burnup Fuel Behavior Under Rod Ejection Accident in the Westinghouse-Designed 950 MWe PWR

  • Chan Bock Lee;Byung Oh Cho
    • Nuclear Engineering and Technology
    • /
    • v.30 no.3
    • /
    • pp.273-286
    • /
    • 1998
  • As there has arisen a concern that failure of the high burnup fuel under the reactivity-insertion accident(RIA) may occur at the energy lower than the expected, fuel behavior under the rod ejection accident in a typical Westinghouse-designed 950 MWe PWR was analyzed by using the three dimensional nodal transient neutronics code, PANBOX2 and the transient fuel rod performance analysis code, FRAP-T6. Fuel failure criteria versus the burnup was conservatively derived taking into account available test data and the possible fuel failure mechanisms. The high burnup and longer cycle length fuel loading scheme of a peak rod turnup of 68 MWD/kgU was selected for the analysis. Except three dimensional core neutronics calculation, the analysis used the same core conditions and assumptions as the conventional zero dimensional analysis. Results of three dimensional analysis showed that the peak fuel enthalpy during the rod ejection accident is less than one third of that calculated by the conventional zero dimensional analysis methodology and the fraction of fuel failure in the core is less than 4 %. Therefore, it can be said that the current design limit of less than 10 percent fuel failure and maintaining the core coolable geometry would be adequately satisfied under the rod ejection accident, even though the conservative fuel failure criteria derived from the test data are applied.

  • PDF

Study on Reliability Evaluation for a Taper Grid Coupling (테이퍼 그리드 커플링의 신뢰성 평가에 관한 연구)

  • Jung, Dong Soo
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.343-354
    • /
    • 2017
  • Purpose: This paper evaluates the reliability of tapered grid couplings and presents test results through performance and life tests. Methods: The performance and life test method were presented by analyzing the failure modes for the tapered grid coupling. Zero failure test time was calculated to evaluate the reliability of tapered grid couplings and the test was performed under accelerated conditions. The nondestructive test and wear analysis using weighing were also carried out to check the failure modes of the field conditions. Conclusion: This study can be provided to improve the product reliability through failure analysis of a tapered grid coupling. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the tapered grid coupling.

Applicability of exponential stress-strain models for carbonate rocks

  • Palchik, Vyacheslav
    • Geomechanics and Engineering
    • /
    • v.15 no.3
    • /
    • pp.919-925
    • /
    • 2018
  • Stress-strain responses of weak-to-strong carbonate rocks used for tunnel construction were studied. The analysis of applicability of exponential stress-strain models based on Haldane's distribution function is presented. It is revealed that these exponential equations presented in transformed forms allow us to predict stress-strain relationships over the whole pre-failure strain range without mechanical testing of rock samples under compression using a press machine and to avoid measurements of axial failure strains for which relatively large values of compressive stress are required. In this study, only one point measurement (small strain at small stress) using indentation test and uniaxial compressive strength determined by a standard Schmidt hammer are considered as input parameters to predict stress-strain response from zero strain/zero stress up to failure. Observations show good predictive capabilities of transformed stress-stress models for weak-to-strong (${\sigma}_c$ <100 MPa) heterogeneous carbonate rocks exhibiting small (< 0.5 %), intermediate (< 1 %) and large (> 1 %) axial strains.

Life Analysis of Parallel Opening Type Pneumatic Chuck (크랭크 레버형 평행개폐 공기압 척의 수명 분석)

  • Kang, Bo-Sik;Song, Chang-Seop;Jang, Ji-Seong;Ji, Sang-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.9
    • /
    • pp.96-102
    • /
    • 2009
  • In this study, performs analysis of the life of parallel opening type pneumatic chucks that are usually applied in the factory automation line. Pneumatic chucks have complicated failure cause because they are organized as a complex of various elements. Therefore, we analyzed the main failure mode of pneumatic chuck, and then performed life test and performance test according to the international standards. On the basis of these processes, shape parameter of pneumatic chuk is proposed that is the main factor for the calculation of zero failure test time for the reliability of pneumatic chuck and their data analysis of life distribution.

Reliability Evaluation and failure Analysis for High Voltage Ceramic Capacitor (고압 커패시터의 고장분석과 신뢰성 평가)

  • 김진우;송옥병;신승우;이희진;신승훈;유동수
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.337-337
    • /
    • 2001
  • High voltage ceramic capacitors are widely applied in power electronic circuits, such as filters, snubbers, and resonant circuits, due to their excellent features of high voltage endurance and low aging. This paper presents a result of failure analysis and reliability evaluation for high voltage ceramic capacitors. The failure nodes and failure mechanisms were identified in order to understand the failure physics in a component. The causes of failure mechanisms for zero resistance phenomena under withstanding voltage test in high voltage ceramic capacitors molded by epoxy resin were studied by establishing an effective closed-loop failure analysis. Also, the condition for dielectric breakdown was investigated. Particular emphasis was placed on breakdown phenomena at the ceramic-epoxy interface. The validity of the results in this study was confirmed by the results of accelerated testing. Thermal shock test as well as pressure cooker test for high voltage ceramic capacitor mounted on a magnetron were implemented. Delamination between ceramic and epoxy, which, might cause electrical short in underlying circuitry, can occur during curing or thermal cycling. The results can be conveniently used to quickly identify defective lots, determine mean time to failure (MTTF) of each lot at the level of Inspection, and detect major changes in the vendors processes.

  • PDF

신뢰성보증을 위한 2단계 수명시험방식 설계

  • 권영일
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2005.06a
    • /
    • pp.379-384
    • /
    • 2005
  • 신뢰성 보증을 위한 인증시험(reliability qualification test)이나 수락시험(reliability acceptance test)에 있어서 가장 널리 사용되는 시험방식 중의 하나가 무고장 시험방식(zero-failure test)이다. 무고장 시험방식이 선호되는 이유는 요구수명을 주어진 신뢰수준으로 보장하는 시험방식들 중에서 적용이 비교적 수월하며 상대적으로 시험기간이나 시료수를 줄일 수 있다는 점 때문이다. 그러나 무고장 시험의 경우, 시험을 의뢰하는 입장에서는 고장이 하나라도 발생하면 불합격 된다는 부담감을 가질 수 있으며 생산자 위험이 커진다는 단점도 가지고 있다. 본 연구에서는 이러한 문제를 보완한 2단계 시험방식을 설계, 제안하고 시험시간, OC곡선 등 시험방식의 특성을 무고장 시험방식과 비교, 분석하였다.

  • PDF

Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

  • Henderson, David J.;Ginger, John D.;Morrison, Murray J.;Kopp, Gregory A.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.383-400
    • /
    • 2009
  • Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.