• Title/Summary/Keyword: zero-IF

Search Result 707, Processing Time 0.035 seconds

Performance Improvement on Cycloconverter-fed Induction Motor Speed Control System (공침법을 이용한 PbTiO3-Polymer O-3 압전 Composites)

  • Cho, Ok-Kyun;Shin, Hwi-Beom;Yuon, Myung-Joong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.5
    • /
    • pp.352-359
    • /
    • 1987
  • The cycloconverter operating on a circulating current-free mode has many zero crossing points. If an exact zero crossing points are not detected, the three phase-unbalanced currents will flow in a motor. In this paper, the current feedback using a current reference wave is proposed to improve the problems of zero crossing detection, three phase-unbalanced voltages, currents, and torgue ripples. To prevent the saturation of the air gap flux and keep the torque constant, the constant voltage / hertz control with IR compensation is adopted. The PI-controller is designed using the linearized model of the cycloconverterinduction motor system. Alsi, Z-80A single board computer has been used to implement the proposed scheme which results in the performance improvement of cycloconterter-fed induction motor speed control system.

  • PDF

STABILITY OF ZEROS OF POWER SERIES EQUATIONS

  • Wang, Zhihua;Dong, Xiuming;Rassias, Themistocles M.;Jung, Soon-Mo
    • Bulletin of the Korean Mathematical Society
    • /
    • v.51 no.1
    • /
    • pp.77-82
    • /
    • 2014
  • We prove that if ${\mid}a_1{\mid}$ is large and ${\mid}a_0{\mid}$ is small enough, then every approximate zero of power series equation ${\sum}^{\infty}_{n=0}a_nx^n$=0 can be approximated by a true zero within a good error bound. Further, we obtain Hyers-Ulam stability of zeros of the polynomial equation of degree n, $a_nz^n$ + $a_{n-1}z^{n-1}$ + ${\cdots}$ + $a_1z$ + $a_0$ = 0 for a given integer n > 1.

Kaplansky-type Theorems, II

  • Chang, Gyu-Whan;Kim, Hwan-Koo
    • Kyungpook Mathematical Journal
    • /
    • v.51 no.3
    • /
    • pp.339-344
    • /
    • 2011
  • Let D be an integral domain with quotient field K, X be an indeterminate over D, and D[X] be the polynomial ring over D. A prime ideal Q of D[X] is called an upper to zero in D[X] if Q = fK[X] ${\cap}$ D[X] for some f ${\in}$ D[X]. In this paper, we study integral domains D such that every upper to zero in D[X] contains a prime element (resp., a primary element, a t-invertible primary ideal, an invertible primary ideal).

Zeros and Step Response αlaracteristics in LTI SISO Systems (선형시불변 단일입출력 시스템의 영점과 계단응답 특성)

  • Lee, Sang-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.8
    • /
    • pp.804-811
    • /
    • 2009
  • This paper deals with the relationship between zeros and step response of the second and third order LTI(Linear Time Invariant) SISO(Single-Input and Single-Output) systems. As well known, if a system has a single unstable zero, it shows the step response with undershoot and, on the other hand, a stable zero slower than the dominant pole causes the system to have the step response with overshoot. Generally, in the case of a system with two unstable real zeros, it is known to have B type undershoot[7]. But there are many complex cases of the step response extrema corresponding to zeros location in third order systems. This paper investigates the whole cases depending on DC gains of the additive equivalence systems and they are to be classified by the region of zeros which are related to the shape of the step response. Moreover, monotone nondecreasing conditions are proposed in the case of complex conjugate zeros as well as the case of two stable zeros.

A Study on the Algorithm for Fault Discrimination in Transmission Lines using Advanced Computational Intelligence(ACI) (ACI 기법을 이용한 송전선로 고장 종류 판별에 관한 연구)

  • Park Jae Hong;Lee Jong Beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.619-621
    • /
    • 2004
  • This paper presents the rapid and accurate algorithm for fault discrimination in transmission lines. When faults occur in transmission lines, fault discrimination is very important. If high impedance faults occur in transmission lines, it cannot be detected by overcurrent relays. The method using current and voltage cannot discriminate high impedance fault. Because of this reason this paper uses voltage and zero sequence current, and the proposed algorithm uses fuzzy logic method. This algorithm uses voltage and zero sequence current per period in case of faults. Single line ground fault and three-phase fault can be detective using voltage. Two-line ground fault and line to line fault and high impedance can be detected using zero sequence current. To prove the performance of the algorithm, it test algorithm with signal obtained from ATPDraw simulation.

  • PDF

Design of Zero Cross Detection Power Factor Correction IC (Zero Cross Detection Power Factor Correction IC 설계)

  • Seo, Kil-Soo;Kim, Hyoung-Woo;Kim, Ki-Hyun;Park, Hyeon-Il;Kim, Nam-Kyun;Park, Ju-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.519-520
    • /
    • 2008
  • In this paper, we design and implement the monolithic zero crossing detection power factor correction IC using a high voltage 30V BCD process. The ZCD PFC IC is designed for power applications, such as notebook, LCD monitor, etc. It includes power factor correction function and several protection circuit, regulator, high-voltage high current output drivers. And also, the designed IC has restart timer function which the output pulse is generated if the output signal of IC is not in a 200us. The simulation results show that the designed IC acts properly as power factor correction IC with efficient protective functions.

  • PDF

A Case Study on Efficiency Worker blunder Preventive Management (효율적 작업자 실수 예방 관리 사례연구)

  • Ryu Byung-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.27-42
    • /
    • 2006
  • Considering in view of China's low price and Japan's high technology, the most important point is the quality of product. To increase the comparative power internationally all workingmen have to fulfill the responsibility to maximize the quality, and this is possible practiced under 'Zero Defect' spirit. To reduce the defect ratio to 'Zero' the workingmen have to recognize own fault, all the manufacturing process should be conducted under 'Fool Proof System', If done under this circumstances, then labor force can work comfortably and safely without nervousness and tiresome. The productivity and quality can increase ultimately and even foreign labor, imbecile child, old-aged labor can participate in work, which can reduce shortage of labor source. Therefore, in this study all defects in manufacturing process, it would be recognized the errors and mistakes caused by human.

Establishment of Zero-Accident Goal Period Based on Time Series Analysis of Accident Tendency (재해율 예측에 근거한 사업장별 무재해 목표시간의 설정)

  • 최승일;임현교
    • Journal of the Korean Society of Safety
    • /
    • v.7 no.2
    • /
    • pp.5-13
    • /
    • 1992
  • If zero-accident movement is to be successful, the objective goal period should be surely obtainable, and much more in our country where frequency rate of injury are remarkably fluc-tuating. However In our country, as far as we know, no method to establish a reasonable zero-accident goal period is guaranteed. In thls paper, a new establishing-method of reasonable goal period for individual industry with considering recent accident trend is presented. A mathematical model for industrial accidents generation was analyzed, and a stochastic process model for the accident generation inteual was formulated. This model could tell the accident generation rate in future by understanding the accident tendency through the time-series analysis and search for the distribution of numbers of accidents and accident interval. On the basis of this, the forecasting method of goal achievement probability by the size and the establishment method of reasonable goal period were developed.

  • PDF

ON SENDOV'S CONJECTURE ABOUT CRITICAL POINTS OF A POLYNOMIAL

  • Nazir, Ishfaq;Mir, Mohammad Ibrahim;Wani, Irfan Ahmad
    • Korean Journal of Mathematics
    • /
    • v.29 no.4
    • /
    • pp.825-831
    • /
    • 2021
  • The derivative of a polynomial p(z) of degree n, with respect to point α is defined by Dαp(z) = np(z) + (α - z)p'(z). Let p(z) be a polynomial having all its zeros in the unit disk |z| ≤ 1. The Sendov conjecture asserts that if all the zeros of a polynomial p(z) lie in the closed unit disk, then there must be a zero of p'(z) within unit distance of each zero. In this paper, we obtain certain results concerning the location of the zeros of Dαp(z) with respect to a specific zero of p(z) and a stronger result than Sendov conjecture is obtained. Further, a result is obtained for zeros of higher derivatives of polynomials having multiple roots.

Interleaved ZVS Resonant Converter with a Parallel-Series Connection

  • Lin, Bor-Ren;Shen, Sin-Jhih
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.528-537
    • /
    • 2012
  • This paper presents an interleaved resonant converter with a parallel-series transformer connection in order to achieve ripple current reduction at the output capacitor, zero voltage turn-on for the active switches, zero current turn-off for the rectifier diodes, less voltage stress on the rectifier diodes, and less current stress on the transformer primary windings. The primary windings of the two transformers are connected in parallel in order to share the input current and to reduce the root-mean-square (rms) current on the primary windings. The secondary windings of the two transformers are connected in series in order to ensure that the transformer primary currents are balanced. A full-wave diode rectifier is used at the output side to clamp the voltage stress of the rectifier diode at the output voltage. Two circuit modules are operated with the interleaved PWM scheme so that the input and output ripple currents are reduced. Based on the resonant behavior, all of the active switches are turned on under zero voltage switching (ZVS), and the rectifier diodes are turned off under zero current switching (ZCS) if the operating switching frequency is less than the series resonant frequency. Finally, experiments with a 1kW prototype are described to verify the effectiveness of the proposed converter.