• 제목/요약/키워드: zero current soft switching

검색결과 225건 처리시간 0.024초

Zero-Voltage-Transition Synchronous DC-DC Converters with Coupled Inductors

  • Rahimi, Akbar;Mohammadi, Mohammad Reza
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.74-83
    • /
    • 2016
  • A new family of zero-voltage-transition converters with synchronous rectification is introduced in this study. Soft switching condition for all the converter operating points is provided in the proposed converters. The reverse recovery losses of the rectifier switch body diode are also eliminated. In comparison with the main switch voltage stress, the auxiliary switch voltage stress is reduced significantly. The auxiliary switch does not need the floating gate drive. The auxiliary inductor is coupled with the main converter inductor, and the leakage inductor is used as the resonance inductor. Thus, all inductors of the proposed converter can be implemented on a single core. The other features of the proposed converters include no extra voltage and current stresses on the main converter semiconductor elements. Theoretical analysis for a synchronous buck converter is presented in detail, and the validity of the theoretical analysis is justified with the experimental results of a prototype buck converter with 180 W and 80 V to 30 V.

공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선 (The improvement of sterilization effective using resonance inverter Power conversion device)

  • 김주용;김영문;권순걸;이현우;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

단일 보조 스위치를 이용한 ZC-ZVS PWM DC-DC 컨버터 (ZC-ZVS PWM DC-DC Converter using One Auxiliary Switch)

  • 박진민;박영조;서기영;문상필;김영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.158-161
    • /
    • 2003
  • A new soft switching technique that improves performance of the high power factor boost rectifier by reducing switching losses is introduced. The losses are reduced by air active snubber which consists of an inductor, a capacitor a rectifier, and an auxiliary switch. Since the boost switch turns off with zero current, this technique is well suited for implementations with insulated gate bipolar transistors. The reverse recovery related losses of the rectifier are also reduced by the snubber inductor which is connected in series with the boost switch and the boost rectifier. In addition, the auxiliary switch operates with zero voltage switching. A complete design procedure and extensive performance evaluation of the proposed active snubber using a 1.2[kW] high power factor boost rectifier operating from a $90[V_{rms}]$ input are also presented.

  • PDF

새로운 액티브 스너버 셀을 적용한 ZVT PWM DC-DC 컨버터 (Zero-Voltage-Transition PWM DC-DC Converter Using A New Active-Snubber-Cell)

  • 하이 뜨란;아디스티라;김선주;최세완
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.273-280
    • /
    • 2018
  • This paper proposes a zero-voltage-transition pulse-width modulation (PWM) DC-DC converter that uses a new active-snubber-cell. The converter main switch can be turned on and off with ZVS, while the snubber switch is turned on with ZCS and turned off with ZVS. Other semiconductor devices are operated under the soft-switching condition. Normal PWM control can be used, the proposed active-snubber-cell does not impose any additional voltage and current stresses. The active-snubber-cell is suitable for high-power applications due to its easy integration into interleaved converters. This paper discusses the operation of the converter, presents some design guidelines, and provides the results of an experiment with a 100 kHz and 1 kW prototype. A peak efficiency of 97.8% is recorded.

개선된 전파형 ZVT PWM DC-DC 컨버터 (Improved Full Wave Mode ZVT PWM DC-DC Converters)

  • 김태우;김학성
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.10-16
    • /
    • 2004
  • 본 논문에서는 공진 에너지 회생율을 최대화하여 전체적인 효율을 증가시킨 개선된 전파형 ZVT(Zero-Voltage-Transition) PWM(Pulse-Width-Modulation) DC-DC 컨버터를 소개한다. 개선된 회로는 단지 기존 컨버터의 보조스위치와 공진형 인덕터 사이에 직렬로 역공진 저지 다이오드를 추가로 달아서 모든 스위칭 소자들이 소프트 스위칭 조건에서 턴온/턴오프하여 스위칭 손실을 최소화하고, 공진 에너지를 완전히 입력으로 회귀시켜 전도손실을 절감하여 효율의 증감을 이루었다. 본 논문에서는 부스터 컨버터를 이용하여 개선된 컨버터의 동작을 분석하고, 실험결과를 바탕으로 제안된 회로의 타당성을 입증하였다.

1차 지연회로를 사용한 ZVS Full-Bridge 컨버터 구동회로 설계 (The Driving Circuit Design for ZVS Full-Bridge Converter with 1st Order Delay Circuit)

  • 조내수;최연호;윤경섭;구본호;권우현
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.569-574
    • /
    • 2010
  • The full bridge converter have been used for high power system that is needed to switch the big current. So, EMI and stability problem is occurred. The Soft switching method is the solution to solve the above problem, But implementation of soft switching(ZVS: Zero Voltage Switching) is so complicate and expensive because of the DSP MCU and shift circuit. In this paper, we introduce the technical method for driving circuit of ZVS full bridge converter with 1st order delay circuit and logic elements. The realization of this method is so simple and cheap. The effectiveness of the proposed circuit is verified by experimental results.

Analysis and Implementation of a DC-DC Converter with an Active Snubber

  • Lin, Bor-Ren;Lin, Li-An
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.779-786
    • /
    • 2011
  • This paper presents a soft switching converter to achieve the functions of zero voltage switching (ZVS) turn-on for the power switches and dc voltage step-up. Two circuit modules are connected in parallel in order to achieve load current sharing and to reduce the size of the transformer core. An active snubber is connected between two transformers in order to absorb the energy stored in the leakage and magnetizing inductances and to limit the voltage stresses across the switches. During the commutation stage of the two complementary switches, the output capacitance of the two switches and the leakage inductance of the transformers are resonant. Thus, the power switches can be turned on under ZVS. No output filter inductor is used in the proposed converter and the voltage stresses of the output diodes is clamped to the output voltage. The circuit configuration, the operation principles and the design considerations are presented. Finally, laboratory experiments with a 340W prototype, verifying the effectiveness of the proposed converter, are described.

Full-bridge Converter의 새로운 ZVS 스위칭 기법 (Novel ZVS Switching Method of Full-bridge Converter)

  • 김승룡;선한걸;한만승;박성준
    • 전력전자학회논문지
    • /
    • 제16권5호
    • /
    • pp.477-483
    • /
    • 2011
  • 일반적인 DC/DC 전력변환기의 스위칭 방식은 하드 스위칭 방식과 공진을 이용한 소프트 스위칭 방식으로 분류할 수 있으며, 하드 스위칭 방식은 스위치의 턴 온/오프시 스위칭 소자에 생기는 전력손실이 커서 효율 면에서 불리하며, 공진형 소프트 스위칭 방식은 별도의 리액터와 커패시터를 추가함으로서 시스템의 사이즈와 비용이 증가하는 단점이 있다. 본 논문에서는 이러한 단점을 극복하기 위해 새로운 스위칭 방식의 소프트 스위칭 방식의 Full-bridge 전력변환기의 구조를 제안하였으며, 제안된 소프트 스위칭 방식은 앞단의 벅 컨버터의 다이오드 전류시 영전압이 되는 구간에서 Full-Bridge 컨버터의 스위치를 교변 함으로써 리액터와 커패시터의 추가없이 소프트 스위칭을 이루어냄으로서 시스템의 효율과 신뢰성을 향상시킨다. 또한 제안된 절연형 소프트 Full-bridge DC/DC 컨버터의 타당성을 검증하기 위해 Psim을 이용한 시뮬레이션과 500[W]급 DC/DC 컨버터를 제작하여 DC/DC 컨버터의 효율이 우수함을 확인하였다.

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

자려식 전류형 고주파 공진 인버터의 특성해석 (Characteristic analysis of self tuning controlled current fed high frequency resonant inverter)

  • 송진화;김동희;노채균;황계호;이봉섭;심광열;정성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2638-2640
    • /
    • 1999
  • This paper proposes a current-fed type high frequency inverter using a soft switching technology Zero-Voltage-Switching to reduce turn on and off loss at the switching. The analysis of the proposed circuit was described by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. In the future, the proposed circuit is considered to be useful for induction heating applications.

  • PDF