• 제목/요약/키워드: xenon light

검색결과 83건 처리시간 0.025초

악성종양의 형광영상 진단을 위한 다파장 여기광원장치의 개발과 평가 (Development and Evaluation of Multi-Wavelength Excitation light Source for Fluorescence Imaging to Diagnose Malignancies)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권2호
    • /
    • pp.113-121
    • /
    • 2009
  • This study aims at designing and evaluating light source devices that can stably generate light with various wavelengths in order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands. It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-420nm, 430-480nm, and 480-560nm. The transmission part of the light source was developed to enhance the efficiency of light transmission. To evaluate this light source, the characteristics of light output and wavelength band were verified. To validate the capability of this device as PDD, the detection of auto-fluorescence using mouse models was performed.

도파된 UV 빛에 의한 광섬유 단면의 폴리머 팁 제작 (Fabrication of polymer tip on an optical fiber end-face by guided UV light)

  • 박민규;정호중;오경환
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2009년도 동계학술발표회 논문집
    • /
    • pp.147-148
    • /
    • 2009
  • We have fabricated a down tapered polymer tip on optical fiber end-face by a guided UV light. One side of fiber was aligned with a mercury-xenon lamp and another was put into UV curable polymer. A shape of tip was controlled by adjusting an irradiance of lamp and time of exposure. A bending effect also affects the result. Optical characteristic was achieved preliminarily with solution of minute particles.

  • PDF

군용 도포직물의 내후성시험 대체에 대한 연구 (A Study on the Alternative Method for Weathering Test of Military Coated Fabrics)

  • 손찬영
    • 품질경영학회지
    • /
    • 제44권3호
    • /
    • pp.509-526
    • /
    • 2016
  • Purpose: We would like to find the alternative method for the weathering test on rubber coated fabrics and adhesive-coated fabrics for the military products, KS M 0706 (Sunshine carbon arc) to KS M ISO 4892-2 (Xenon arc). Methods: We measured the tensile strength of adhesive-coated fabrics and adhesive products treated with sunshine carbon arc and xenon arc during 100, 150 and 200 hours, respectively. All of the results were treated with statistical test, ANOVA method. We also validate the surface modifications caused by treatment method and time by using FT-IR ATR and, SEM. Results: In case of the thick adhesive-coated fabrics (app. 1 mm), there was no distinctive difference on tensile strength by treatment method and time. In case of the thin mask hood (app. 0.22 mm) and TENT (app. 0.5 mm), there was distinctive difference on tensile strength. Especially, carbon arc showed a huge lowering properties. We could validate the curing from light and moisture, and the functional group change from cross-linking and oxidation using FT-IR ATR. In case of IBS, there was a surface cracks on SEM images. In case of mask hood, there was no distinctive differences, except for a particle falling from decreased affinity between rubber and particles caused by carbon arc. Conclusion: We concluded that there was no problems for changing xenon arc weathering test with same treatment time on IBS, KM7, K21 and adhesive products. In case of TENT and mask hood, there was a difference in tensile strength in accordance with the change of the treated time and method.

광중합기의 광원에 따른 브라켓 전단결합강도 비교 (Comparison of the shear bond strength of brackets in regards to the light curing source)

  • 차정열;이기준;박선형;김태원;유형석
    • 대한치과교정학회지
    • /
    • 제36권3호
    • /
    • pp.198-206
    • /
    • 2006
  • 제논 플라즈마 아크 광중합기나 LED 광중합기가 치과영역에 소개된 이후로 기존의 텅스텐 할로겐 광중합기를 사용할 때에 비해 교정장치의 부착시간이 현저하게 줄어들 수 있게 되었다. 제논 플라즈마 아크 광중합기에 대한 중합시간과 전단강도에 대해서는 여러 연구가 있어왔던 반면, LED 광중합기를 이용하여 교정용장치의 부착을 위한 중합시간에 대한 연구는 미진하다. 본 연구의 목적은 LED 광중합기의 중합시간에 따른 결합강도를 플라즈마 아크 광중합기와 비교하여 적절한 브라켓의 부착강도를 얻기 위해 요구되는 중합시간을 알아보는데 있다. 120개의 발치된 사람의 소구치에 컴포짓 레진으로 브라켓을 부착시킨 후 4초, 6초, 8초 동안 플라즈마 아크 광원과 LED 광원으로 각각 중합시켰다. 그 후 결합강도를 만능시험기(Universal Testing Machine)로 계측한 결과, 플라즈마 아크 광중합기에서는 4초 이상에서, LED 광중합기에서는 8초 이상의 중합시간에서 기존의 할로겐 광원을 40초간 노출시켰을 때와 비슷한 전단결합강도를 나타내었다. 플라즈마 아크 광중합기와 LED 광중합기의 중합시간이 접착제 잔류지수 (adhesive remnant index) 수치에 대해 영향을 미치지 않았다.

유기전하이동착체 랭뮤어-블로젯 초박막의 광전도 특성 (Photoelectric Properties of Organic Charge Transfer Complex Langmuir-Blodgett Ultra Thin Films)

  • 정순욱
    • 한국응용과학기술학회지
    • /
    • 제18권1호
    • /
    • pp.49-54
    • /
    • 2001
  • Ultra-thin films of organic charge transfer complex were prepared on a hydrophilic substrate by Langmuir-Blodgett(LB) technique. In this study, the photoelectric properties of a LB film consisting of (N-docosyl quinolinium)-TCNQ(1:2) complex was investigated. The visible light(${\lambda}$ : 700 nm) of xenon lamp was illuminated on the LB films and light absorptivity and photoconductivity were observed. The photocurrent increased linearly and was saturated at the light intensity of 23 ${\mu}W/cm^{2}$.

녹색발광 Zn2SiO4:Mn2+ 형광체가 코팅된 엑시머 램프의 제작 및 특성 (Fabrication and Property of Excimer Lamp Coated with Green-emitting Zn2SiO4:Mn2+ Phosphor Film)

  • 강부식;정현지;정용석;손세모;김종수
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.106-109
    • /
    • 2022
  • The green-emitting Zn2SiO4:Mn2+ phosphor film was evaluated in a xenon excimer lamp. The phosphor film with 2 ㎛ thick was formed of monolithic structure on the inner side of quartz through a long-time annealing process of coated ZnO solution doped with Mn2+ ion and SiO2 of quartz tube. The coated quartz was filled with 100 torr of xenon gas, and simultaneously both sides was melt and sealed. The xenon-field quartz tube was discharge by applying the voltage of 15 kV with a frequency of 26 kHz, and emitted the glow with dominant peak at 172 nm. The vacuum ultraviolet excited the inner-side coated Zn2SiO4:Mn2+ phosphor film, which emitted the pure and strong green light.

Intense Pulsed Light의 안전성 및 성능평가를 위한 시험 항목 및 시험방법(안) 연구 (Guideline Development to Evaluate the Safety and Performance of Intense Pulsed Light(IPL))

  • 강동연;손태윤;주예일;최응호;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제31권2호
    • /
    • pp.129-133
    • /
    • 2010
  • Intense pulsed light(IPL) is a photo-therapeutic medical device using xenon lamps with optical characteristics of incoherence, defocusing, and polychromatic. IPL has been recognized as a representative medical therapeutic device with growth of domestic skin care market. However, there is no standard regulation manual and guideline to evaluate the safety and performance of IPL. International Electrotechnical Commission(IEC) is being statued "Technical Report IEC TR 60825-16" which is a guidelines for the safe use of intense light source equipment on humans and animals. In this study, a standard Korea Food & Drug Administration (KFDA) regulation for the safety and performance of IPL was suggested by developing minimal evaluation methods for optical parameters of IPL such as output energy density, pulse mode, spot size, wavelength and uniformity of output light. We expect that this study may be a step to statue a standard regulation manual and guideline for IPLs used in domestic.

Development portable hair removal applies PET ($Pause^{10-90}$ and $Energy^{20-40}$ $Trigger^{1-7}$) function

  • Kim, Whi-Young
    • Journal of information and communication convergence engineering
    • /
    • 제7권2호
    • /
    • pp.223-230
    • /
    • 2009
  • For pulse trigger way and the energy injection rate according to PET ($Pause^{10-90}$ $Energy^{20-40}$ $Trigger^{1-7}$) function, indeed, human body condition, period of dormancy in this research about this back correctly adjustment possible and designed harmless micro carrying along style hair exclusion so that can design and manufacture and run special quality examination and Xenon flash lamp to crawl in human body. Because creating individual's skin model to do stable treatment by light transmission way by skin impedance and measure, must embody treatment special quality of most suitable that draw skin color, energy, wave length, approximately, transmission time, pulse delay etc. and want. Specially, saved standard of war treatment pulse modeling by skin impedance, and manufacture pulse modeling system of most suitable by skin subordinate, and embody suitable treatment pulse. Specially, embody as could do root of a hair exclusion being emitted in pulse form using multi wave length of 560nm, 590nm, 640nm, 755nm and embodied clinical data. If become research repletion furthermore little more, is seen that can approximate in commercialization.

광소결용 제논 램프 구동을 위한 파워 서플라이 시스템 (The Power Supply System for Xenon Lamp Light Sintering)

  • 조찬기;송승호;박수미;박현일;배정수;장성록;류홍제
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.327-328
    • /
    • 2017
  • This paper presents the power supply system which is made of three units: the capacitor charging and main pulse unit, simmer power supply unit, and series trigger unit. The capacitor charging and main pulse unit charges the capacitor bank by using the series parallel resonant converter and the generated main pulses apply to the lamp. The series trigger unit ionize the xenon gas located in the lamp and the simmer power supply unit sustains the ionized condition. It means that the lamp lifetime and efficiency are advanced by reducing the number of triggering. Not only the operation of the proposed system but also the performance of each unit will be verified by the experimental results.

  • PDF