• Title/Summary/Keyword: x-ray noise

Search Result 258, Processing Time 0.024 seconds

Noise Reduction of medical X-ray Image using Wavelet Threshold in Cone-beam CT (Cone-beam CT에서 웨이브렛 역치값을 이용한 x-ray 영상에서의 노이즈 제거)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-Oh;Jeon, Sung-Chae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.42-48
    • /
    • 2007
  • In x-ray imaging system, two kinds of noises are involved. First, the charge generated from the radiation interaction with the detector during exposure. Second, the signal is then added by readout electronics noise. But, x-ray images are not modeled by Gaussian noise but as the realization of a Poisson process. In this paper, we apply a new approach to remove Poisson noise from medical X-ray image in the wavelet domain, the applied methods shows more excellent results in cone-beam CT.

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Noise Characteristic Analysis of X-Ray Fluorescence Spectrum (형광 X-선 스펙트럼의 잡음 특징 분석)

  • Lee, Jae-Hwan;Chon, Sun-Il;Yang, Sang-Hoon;Park, Dong-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2298-2304
    • /
    • 2012
  • X-ray fluorescence spectrum analysis method can be applied in many areas, including concentration analysis of RoHS elements and heavy metals etc. and we can get analysis results in a relatively short time. Because X-ray fluorescence spectrum has noises and several artifacts that lowers the accuracy of the analysis. This paper analyzes the characteristics of the noise of the X-ray fluorescence spectrum to increase the accuracy of analysis. X-ray fluorescence spectrum have the characteristics of shot noise (Poisson noise), so the noise size is relatively large in the small signal portion and the noise the size is relatively small in the large part of the signal. Existing methods of analysis and to remove noises is a method for general purposes algorithm. Since these algorithm does not reflect these noise characteristics, we get distorted analysis result. We can design efficient noise remove algorithm based on the accurate noise analysis method, and we expect high accuracy results of the elemental concentration analysis result.

X-ray Absorptiometry Image Enhancement using Sparse Representation (Sparse 표현을 이용한 X선 흡수 영상 개선)

  • Kim, Hyungil;Eom, Wonyong;Ro, Yong Man
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.10
    • /
    • pp.1205-1211
    • /
    • 2012
  • Recently, the evaluating method of the bone mineral density (BMD) in X-ray absorptiometry image has been studied for the early diagnosis of osteoporosis which is known as a metabolic disease. The BMD, in general, is evaluated by calculating pixel intensity in the bone segmented regions. Accurate bone region extraction is extremely crucial for the BMD evaluation. So, a X-Ray image enhancement is needed to get precise bone segmentation. In this paper, we propose an image enhancement method of X-ray image having multiple noise based sparse representation. To evaluate the performance of proposed method, we employ the contrast to noise ratio (CNR) metric and cut-view graphs visualizing image enhancement performance. Experimental results show that the proposed method outperforms the BayesShrink noise reduction methods and the previous noise reduction method in sparse representation with general noise model.

Regional Image Noise Analysis for Steel-tube X-ray Image (강판튜브 엑스선 영상의 영역별 영상잡음 특성분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.32-34
    • /
    • 2007
  • The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.

  • PDF

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.

X-Ray Image Enhancement Using a Boundary Division Wiener Filter and Wavelet-Based Image Fusion Approach

  • Khan, Sajid Ullah;Chai, Wang Yin;See, Chai Soo;Khan, Amjad
    • Journal of Information Processing Systems
    • /
    • v.12 no.1
    • /
    • pp.35-45
    • /
    • 2016
  • To resolve the problems of Poisson/impulse noise, blurriness, and sharpness in degraded X-ray images, a novel and efficient enhancement algorithm based on X-ray image fusion using a discrete wavelet transform is proposed in this paper. The proposed algorithm consists of two basics. First, it applies the techniques of boundary division to detect Poisson and impulse noise corrupted pixels and then uses the Wiener filter approach to restore those corrupted pixels. Second, it applies the sharpening technique to the same degraded X-ray image. Thus, it has two source X-ray images, which individually preserve the enhancement effects. The details and approximations of these sources X-ray images are fused via different fusion rules in the wavelet domain. The results of the experiment show that the proposed algorithm successfully combines the merits of the Wiener filter and sharpening and achieves a significant proficiency in the enhancement of degraded X-ray images exhibiting Poisson noise, blurriness, and edge details.

Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image (경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

3D Non-local Means(NLM) Algorithm Based on Stochastic Distance for Low-dose X-ray Fluoroscopy Denoising (저선량 X-ray 영상의 잡음 제거를 위한 확률 거리 기반 3차원 비지역적 평균 알고리즘)

  • Lee, Min Seok;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.4
    • /
    • pp.61-67
    • /
    • 2017
  • Low-dose X-ray fluoroscopic image sequences to avoid radiation exposure risk are contaminated by quantum noise. To restore these noisy sequences, we propose a 3D nonlocal means (NLM) filter based on stochastic distancesed can be applied to the denoising of X-ray fluoroscopic image sequences. The stochastic distance is obtained within motion-compensated noise filtering support to remove the Poisson noise. In this paper, motion-adaptive weight which reflected the frame similarity is proposed to restore the noisy sequences without motion artifact. Experimental results including comparisons with conventional algorithms for real X-ray fluoroscopic image sequences show the proposed algorithm has a good performance in both visual and quantitative criteria.

The Effects of Total Variation (TV) Technique for Noise Reduction in Radio-Magnetic X-ray Image: Quantitative Study

  • Seo, Kanghyen;Kim, Seung Hun;Kang, Seong Hyeon;Park, Jongwoon;Lee, Chang Lae;Lee, Youngjin
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.593-598
    • /
    • 2016
  • In order to reduce the amount of noise component in X-ray imaging system, various reduction techniques were frequently used in the field of diagnostic imaging. Although the previous techniques -such as median, Wiener filters and Anscombe noise reduction technique - were able to reduce the noise, the edge information was still damaged. In order to cope with this problem, total variation (TV) noise reduction technique has been developed and researched. The purpose of this study was to evaluate and compare the image quality using normalized noise power spectrum (NNPS) and contrast-to-noise ratio (CNR) through simulations and experiments with respect to the above-mentioned noise reduction techniques. As a result, not only lowest NNPS value but also highest CNR values were acquired using a TV noise reduction technique. In conclusion, the results demonstrated that TV noise reduction technique is proved as the most practical method to ensure accurate denoising in X-ray imaging system.