• Title/Summary/Keyword: x-ray diffraction analysis

Search Result 2,273, Processing Time 0.024 seconds

Comparison of Microscopic Method with X-ray Diffraction Analysis of Rock Minerals (주요암석(主要岩石) 광물(鑛物)에 대(對)한 현미경적분석(顯微鏡的分析)과 X-선회절분석(線回折分析)과 비교(比較))

  • Choi, Dae Ung;Hwang, Kyung Sun;Shin, Jae Sung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.6 no.4
    • /
    • pp.253-255
    • /
    • 1973
  • Microscopic method was compared with X-ray diflraction analysis for the identification of rockforming minerals using 11 main rock samples in Korea. 1. There was no difference between X-ray diffraction analysis and microscopic one in major minerals, but some accessary minerals. 2. The rock-forming minerals of main rocks presented in this study occured almost in crystalline state so that they could be easily identified by X-ray analysis alone.

  • PDF

Clay Minerals and Their Distribution in the Soft Ground Deposited along the Coastline (한국 해안에 퇴적된 연약지반의 점토광물의 종류와 분포)

  • 김상규;임희대;문성권
    • Geotechnical Engineering
    • /
    • v.14 no.6
    • /
    • pp.73-80
    • /
    • 1998
  • In order to identify clay minerals in the soft ground, which has been deposited along the coastline of the Korean peninsula, 14 samples have been taken at different locations and then X-ray diffraction analysis is carried out for them. It is known from the analysis that the various kinds of clay minerals mixed with different portions exist in the soft ground, but halloysite is not traced in any samples. It is featured regionally that kaolinite and illite are found in the western coast and the southern coast. Montmorillonites exists only in the western coast. This feature of regional occurrences can be explained with the help of geology of the region. Activities determined from physical properties of the soils do not coincide with those of clay minerals identified from X-ray diffraction analysis.

  • PDF

A Study on the Precipitates in Rapidly Solidified Al-(Fe, Ce) Alloys by Analysis of X-Ray Diffraction (급냉응고된 Al-(Fe, Ce) 합금에서 형성되는 석출상의 X-선적연구)

  • Park, Ik-Min;Lee, Kyu-Han;Choe, Jeong-Cheol;Jo, Hyung-Ho
    • Journal of Korea Foundry Society
    • /
    • v.8 no.4
    • /
    • pp.446-452
    • /
    • 1988
  • To obtain detailed information on the metastable and the equilibrium phases in rapidly solidified Al-(Fe,Ce) alloys, analysis of X-ray diffraction pattern has been carried out. It has been found that the metastable phase formed in Al-Fe alloys including up to 6wt%Fe is $Al_6Fe$ and the equilibrium phase is $Al_3Fe$. Any X-ray diffraction peak corresponding to the equilibrium phase $Al_{13}Fe_4$ has not been observed during aging. In Al-4wt%Fe alloy, which is ribbon shape with thickness less than $70\;{\mu}m$, aged at $400^{\circ}C$ for 1h after rapid solidification, unidentified phase has been found. In Al-4wt%Ce alloy, only X-ray diffraction peak corresponding to the equilibrium phase, $Al_4Ce$ has been observed. It has been found that the metastable phase Formed in Al-Fe-Ce alloys including up to 6wt% Fe and 4wt% Ce is $Al_6Fe$ and the equilibrium phases are $Al_3Fe$ and $Al_{10}CeFe_2$.

  • PDF

A Study of Practical and Optimized Mineral Quantification (실용적이고 최적화된 광물정량분석법 연구)

  • Son, Byeong-Kook;An, Gi-O
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.227-239
    • /
    • 2021
  • A practical and effective method of X-ray powder diffraction analysis was investigated for quantitative analysis of the mineral content of natural samples. Sample mounting experiments were conducted to select the best randomly oriented powder sample mount. A comparative experiment was also made between a reference intensity ratio (RIR) method, which compares a single peak intensity with standard material, and the Rietveld method, which calculates a full X-ray diffraction pattern, to search for the effective method of mineral quantification. In addition, samples containing amorphous minerals were quantitatively analyzed by the Rietveld method and the efficiency was reviewed. As a result of the study, the optimal random orientation could be reached by the side mounting method. The Rietveld method using the full pattern of X-ray diffraction was more suitable for mineral quantitative analysis, rather than the RIR method using a specific peak. However, either method could depend on the analyst's experience in addition to analytical technique. Moreover, amorphous minerals can be quantitatively analyzed by the Rietveld method, and the analysis results make the geological analysis possible.

Phase Analysis of Mechanically Alloyed $\sigma$-VFe Alloy Powders by Neutron and X-ray Diffraction (기계적 합금화한 $\sigma$-VFe합금의 중성자 및 X선 회절에 의한 상분석)

  • 이충효;조재문;이상진;심해섭;이창희
    • Korean Journal of Materials Research
    • /
    • v.11 no.8
    • /
    • pp.664-664
    • /
    • 2001
  • The mechanical alloying (MA) effect in $\sigma$-VFe intermetallic compound was studied by neutron and X-ray diffraction. The structure of MA $\sigma$-VFe powders were characterized by the X- ray diffraction with Cu- $K\alpha$ radiation and neutron diffraction with monochromatic neutrons of $1.835\AA$ using a high resolution powder diffractometer (HRPD). Mechanical alloying of $\sigma$-VFe compound gives rise to a dramatic structural change. After 60 hours of MA, the Fe-Fe distribution of the $\sigma$- phase VFe tetragonal structure with 30 atoms in a unit cell is found to change into that of the $\sigma$-(V,Fe) solid solution with bcc structure, which is a stable phase at elevated temperature above $1200^{\circ}C$. A comparison of X-ray diffraction data for the $\alpha$-phase has been also made with the corresponding neutron diffraction data. The (101) and (111) diffraction peaks of the $\sigma$-phase was clearly observed only in neutron diffraction pattern, which is believed to be a characteristic feature due to the chemical atomic ordering of $\sigma$- VFe phase.

The Determination of Glass content in fly Ash by X-Ray Diffraction (분말X선회절법에 의한 플라이 애시의 유리질 정량)

  • 이승헌;김홍주
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.159-162
    • /
    • 2000
  • The purpose of this study is to develope an accurate procedure for measuring the glass content of fly ash produced by bituminous coal to assist in predicting their behavior in concrete. Quantitative mineralogical compositions of fly ashes were obtained by internal standard method using powder X-ray diffraction analysis. In the X-ray diffraction method, the specimen and standard fluorite were cautiously mixed and pulverized to 22$\mu$m in wet process so as to avoid the prefered orientation of the crystal and microabsorption effect of X-ray. calibration curve were fitted for several references peaks of four phases:$\alpha$-quartz. mullite, magnetite, hematite. The amount of glass was calculated by subtracting the amount of crystal phase and loss on ignition from the total amount. Glass content determined with this method ranged from 66.7 to 75.wt%.

  • PDF

Characterization of Two-Dimensional Transition Metal Dichalcogenides in the Scanning Electron Microscope Using Energy Dispersive X-ray Spectrometry, Electron Backscatter Diffraction, and Atomic Force Microscopy

  • Lang, Christian;Hiscock, Matthew;Larsen, Kim;Moffat, Jonathan;Sundaram, Ravi
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.131-134
    • /
    • 2015
  • Here we show how by processing energy dispersive X-ray spectrometry (EDS) data obtained using highly sensitive, new generation EDS detectors in the AZtec LayerProbe software we can obtain data of sufficiently high quality to non-destructively measure the number of layers in two-dimensional (2D) $MoS_2$ and $MoS_2/WSe_2$ and thereby enable the characterization of working devices based on 2D materials. We compare the thickness measurements with EDS to results from atomic force microscopy measurements. We also show how we can use electron backscatter diffraction (EBSD) to address fabrication challenges of 2D materials. Results from EBSD analysis of individual flakes of exfoliated $MoS_2$ obtained using the Nordlys Nano detector are shown to aid a better understanding of the exfoliation process which is still widely used to produce 2D materials for research purposes.

Microscopic analysis of gas hydrates using X-ray diffraction method (X-ray diffraction을 이용한 가스 하이드레이트 미세구조 분석)

  • Lee, Jong-Won;Seol, Ji-Woong;Koh, Dong-Yeun;Lee, Huen
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.178-181
    • /
    • 2008
  • 다양한 조성을 갖는 $CH_4+CO_2$ 혼합 기체 하이드레이트 샘플의 미세 구조 분석을 위하여 X-ray 회절 방법을 이용하였다. X-ray 회절 분석을 이용할 경우, 하이드레이트로의 전환율과 같은 정성적인 분석뿐 아니라 각 객체별 cage occupancy와 같은 정량적인 분석까지도 가능한 것으로 나타났다. 또한 이렇게 얻어진 X-ray 회절 분석 결과 및 refinement 결과를 $^{13}C$ 고체 NMR 방법과 교차 비교함으로써 측정 결과의 신뢰도를 높이려 하였다. 얻어진 분석 결과는 이후 가스 하이드레이트를 이용한 다양한 연구 분야에서 저장용량 평가 및 객체 점유율과 같은 미세 구조 정보를 얻는 데에 유용하게 사용될 것으로 전망된다.

  • PDF

X-ray Diffraction Analysis of Residual Stress in Laminated Ceramic

  • Jin, Young-Ho;Chung, Dong-Yoon
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.458-462
    • /
    • 2011
  • The strength of ceramic was improved by lamination by suppressing the propagation of cracks with compressive residual stress in the face layer of the laminate. Hot pressed SiAlON+SiC/SiC/SiAlON+SiC laminate discs were fabricated for tailored residual stress. The residual stress in this laminate was studied by X-ray diffraction (XRD). There was considerable compressive residual stress in the face layer. A Finite Element Analysis (FEA) was performed to support the measured XRD results and to determine the stress field in the laminate. The residual stress measured by XRD had satisfactory agreement with the analytically calculated and FEA values. The measured value by XRD was -385 ${\pm}$ 20 MPa over most of the face layer. The calculated and FEA values were -386 MPa and -371MPa, respectively. FEA also showed significantly modified stresses and the maximum tensile stress near the edge region which are possible crack generators in the presence of flaws or contact damage.

Analysis of Wear Proccess in Sliding Contact by X-ray Diffraction (X선회절에 의한 미끄럼접촉시 발생하는 마모과정의 해석(제1보 : 저경도강의 적용))

  • 이한영
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.19-24
    • /
    • 1999
  • Understanding of wear mode and prediction of wear rate of parts in sliding contact are very important in field of meterial design relating with wear resistant. This paper has been undertaken to analyze the possibility of elucidation of wear mode and prediction of wear rate for annealed steel in sliding contact using the X-ray diffraction. The sliding wear test with various velocities using pin-on-disc machine and the X-ray diffraction test on the worn surface have been carried out. The results have been shown that the magnitude of residual stress and half-value breadth on the worn surface have a good correlation with wear mode. The difference between before and after test of half-value breadth on worn surface has been shown to be exponential relation with wear rate in the same wear mode.

  • PDF