• Title/Summary/Keyword: x-ray detector

Search Result 457, Processing Time 0.027 seconds

Determination of Air-dry Density of Wood with Polychromatic X-ray and Digital Detector

  • Kim, Chul-Ki;Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.836-845
    • /
    • 2017
  • Gravimetric method is usually used to evaluate air-dry density, which is governing physical or mechanical properties of wood. Although it had high evaluation accuracy, the method is time consuming process. Thus, this study was conducted to estimate air-dry density of wood with high accuracy by using polychromatic X-ray and digital detector as alternative of gravimetric method. To quantify polychromatic X-ray projection for evaluating air-dry density, Lambert-Beer's law with the integral value of probability function was used. The integral value was used as weighting factor in the law, and it was determined by conducting simple test at various penetration depths and tube voltage. Mass attenuation coefficient (MAC) of wood also calculated by investigating polychromatic X-ray projection according to species, penetration depth and tube voltage. The species had not an effect on change of MAC. Finally, an air-dry density of wood was estimated by applying the integral value, MAC and Lambert-Beer's law to polychromatic X-ray projection. As an example, the relation of the integral value (${\alpha}$) according to penetration depth (t, cm) at tube voltage of 35 kV was ${\alpha}=-0.00091t{\times}0.0184$ while the regression of the MAC (${\mu}$, $cm^2/g$) was ${\mu}=0.5414{\exp}(-0.0734t)$. When calculation of root mean squared error (RMSE) was performed to check the estimation accuracy, RMSE at 35, 45 and 55 kV was 0.010, 0.013 and $0.009g/cm^3$, respectively. However, partial RMSE in relation to air-dry density was varied according to tube voltage. The partial RMSE below air-dry density of $0.41g/cm^3$ was $0.008g/cm^3$ when tube voltage of 35 kV was used. Meanwhile, the partial RMSE above air-dry density of $0.41g/cm^3$ decreased as tube voltage increased. It was conclude that the accuracy of estimation with polychromatic X-ray and digital detector was quite high if the integral value and MAC of wood were determined precisely or a condition of examination was chosen properly. It was seemed that the estimation of air-dry density by using polychromatic X-ray system can supplant the gravimetric method.

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

X-ray Image Correction Model for Enhanced Foreign Body Detection in Metals (금속 내부의 이물질 검출 향상을 위한 X-ray 영상 보정 모델)

  • Kim, Won
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.15-21
    • /
    • 2019
  • X-rays with shorter wavelengths than ultraviolet light have very good penetration power. It is convergence in industrial and medical fields has been used a lot. n particular, in the industrial field, various researches have been conducted on the detection of foregin body inside metal that can occur in the production process of products such as metal using x-ray, a non-destructive inspection device. Detectors are becoming increasingly popular for the popularization of DR (Digital Radiography) photography methods that digitally acquire X-ray video images. However, there are cases where foreign body detection is impossible depending on the sensor noise and sensitivity inside the detector. When producing a metal product, since the defective rate of the produced product may increase due to contamination of the foreign body, accurate detection is necessary. In this paper, we provide a correction model for X-ray images acquired in order to improve the efficiency of defect detection such as foreign body inside metal. When applied to defect detection in the production process of metal products through the proposed model, it is expected that the detection of product defects can be processed accurately and quickly.

Introduction of Dental X-ray Imaging with New Concept - intra Oral x-ray Tube (신개념 치과용 X-선 영상장치 소개 - 강내형 X-선 튜브)

  • Cho, Sung-Ho;Kim, Dong-Young;Baek, Kwang-Woo;Lee, Re-Na
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.94-101
    • /
    • 2011
  • Various kinds of medical imaging devices have been studied to develop periapical radiography. However, there are some problems such as high x-ray exposure rate and pains for patients because of the problems caused by intra-oral sensor based radiography system. In this study, a new concept of periapical radiography, intra oral X-ray tube and detector system, is introduced to solve these problems. This system is made up of miniature X-ray tube based on subminiature thermal electron or cold electron, CMOS based detector, and a body including automatic position and system control devices. In order to confirm the possibility of proposed new concept to periapical radiography, miniature x-ray tube from XOFT corporation is used to develop new x-ray system, and the performance evaluation of this system is performed according to collimator. Also, dental images are compared after acquiring both images from existing system versus new concept of system. As a result, new concept of system showed excellent image. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Design and Fabrication of HgI2 Sensor for Phosphor Screen based flat panel X-ray Detector (형광체 스크린 기반 평판형 X선 검출기 적용을 위한 요오드화수은 필름 광도전체 센서 설계 및 제작)

  • Park, Ji Koon;Jung, Bong Jae;Choi, Il Hong;Noh, Si Cheol
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.189-194
    • /
    • 2014
  • In this study, from a new x-ray detector that combines a columnar CsI:Na scintillation layer with a photosensitive mercuric iodide layer was investigated. In this structure, X-rays are converted into visible light on a thick CsI:Na layer, which is then converted to electric charges in a thin $HgI_2$ bottom layer. The thin coplanar mercuric iodide films as a photosensitive converter requiring only a few tens of volts of bias, associated with a thick columnar coating of phosphor layer, were simulated and designed. The results of this research suggest that the new coplanar x-ray detector with a hybrid-type structure can resolve the following problems: high voltage from the a-Se, and low conversion efficiency from the indirect conversion method. The results of this research suggest that the new CsI:Na/$HgI_2$ x-ray detector with a double-layer type structure can resolve the following problems: high voltage from the direct conversion method, and low conversion efficiency from the indirect conversion method.

Monte-carlo Simulation for X-ray Photon Counting using MPPC Arrays (배열형 실리콘광증배소자를 이용한 포톤 카운팅 검출기 설계를 위한 몬테칼로 시뮬레이션 연구)

  • Lee, Seung-Jae;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.929-934
    • /
    • 2018
  • Studies for counting and detecting X-rays for the improvement of image quality and material analysis are active. In this work, the detector for X-ray photon counting was designed using Multi-pixel photon counter (MPPC) array and the detector characteristics were evaluated through simulation. Geant4 Application for Tomographic Emission (GATE) was used to obtain the position where the X-ray and the scintillation interacted, and this position was used as the light generation position of DETECT2000. 0.5 mm and 1 mm thick Gadolinium Aluminium Gallium Garnet (GAGG) scintillators were used and the light generated through a $4{\times}4$ array of MPPCs was acquired. The spatial resolution of the designed detector was evaluated by reconstructed image using the light signal acquired for each channel. We obtained images of more than 2 lp/mm in both 0.5 mm and 1 mm thick GAGG scintillation. When this detector is used in a X-ray system, a low-cost system capable of photon counting can be made.

The Development of X-ray Unit of Remote Emergency medical System (원격응급시스템에 적합한 X-ray 장치 개발)

  • Cho, Dong-Heon;Koo, Kyung-Wan;Yang, Hae-Sool;Han, Man-Seok;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.49-54
    • /
    • 2006
  • The X-ray unit developed by this study is to diagnose emergency cases which is too far from a hospital and to classify the patients. We have to use the X-ray in a ambulance or the scene of an accident where we cannot use the AC220 outlet because of the distance from a hospital as well. The X-ray unit developed has a characteristics as follows. First of all, as the unit has a condenser in itself where there is no electric supply, we can use the X-ray inspector in a mountain area or a island. Second, we can detect by digital detector the information taken by X-ray from DC 12[V] electricity and store as a form of file. A control circuit can secure the reliability of the X-ray unit by using the Pic16F84A X-ray and provide various functions. The X-ray unit which suits remote emergency system can be efficiently used for the emergent cases who is too far from a doctor and a hospital or in the situation where it is difficult to diagnose, transcribe and treat simultaneously.

I-V Measurements of large area $HgI_2$ X-ray detector produced by PIB method (PIB법을 이용한 대면적 $HgI_2$ 검출기의 I-V 특성평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Sin, Jeong-Uk;Mun, Chi-Ung;Nam, Sang-Hee;Kim, Jin-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.254-255
    • /
    • 2005
  • In this paper, we investigated electrical characteristics of the X-ray detector of mercuric iodide (HgI2) film fabricated by PIB(Particle-in-Binder) Method on ITO substrates 17cm$\times$20cm in size with thicknesses ranging from approximately 200${\mu}m$ to 240${\mu}m$. In the present study, using I-V measurements, their electrical properties such as leakage current, X-ray sensitivity, and signal-to-noise ratio (SNR),were investigated. The results of our study can be useful in the future design and optimization of direct active-matrix flat-panel detectors (AMFPD) for various digital X-ray imaging modalities.

  • PDF

The Study on Quantum Efficiency of $CaWO_4$ Screen with Diagnostic X-ray (진단 X선에 대한 $CaWO_4$ 증감지의 양자효율 연구)

  • Park, Ji-Koon;Kang, Sang-Sik;Jang, Gi-Won;Lee, Hung-Won;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.379-382
    • /
    • 2002
  • Lately, intensifying screen of the $CaWO_4$ is used to medical treatment and diagnosis of the image. In this paper, we investigated transmission fraction and mass attenuation coefficient of $CaWO_4$ screen about diagnostic x-ray of low energy using MCNP 4C code. Experimentally, for 0.9 mm-$CaWO_4$ screen, the absorbable rate of diagnostic x-ray is more than 95%. according to kVp, the experimental value of mass attenuation coefficient is in a1most agreement with an corrected estimate value of MCNP and the deviation of experimental values is less than ${\pm}7%$. Using the MCNP code through this paper, we can make an estimate of signal and design for construction of the CaWO4/a-Se based digital x-ray image detector and make a good use of the foundation data for development of other materials.

  • PDF