• Title/Summary/Keyword: x-ray analysis

Search Result 4,827, Processing Time 0.034 seconds

Electron Probe Micro Analysis of Cs in $UO_2$ (우라늄산화물중 Cs의 전자탐침 미세분석)

  • Park, Soon Dal;Joe, Kih Soo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.203-211
    • /
    • 2001
  • In this paper it was described on the intereference effect of uranium to analyze Cs in $UO_2$ by Electron Probe Micro Analysis(EPMA) and the beam stability of Cs $L_{\alpha}$ X-ray intensity for some Cs compounds. According to the experimental results, the CsI showed the highest $L_{\alpha}$ X-ray intensity among the tested Cs compounds at the experimental condition; 15~30 kV of accelerating voltage and PET, LiF crystal. When 100 nA of beam current was applied to Cs compounds, Cs $L_{\alpha}$ X-ray intensity was continuously decreased with increasing time. The decreasing rate of Cs $L_{\alpha}$ X-ray intensity was directly proportional to the applied beam current and accelerating voltage but inversely proportional to the applied beam size. It was found that uranium interference can be prevented by using Cs $L_{\alpha}$ X-ray wavelength of Lif crytal for Cs analysis in $UO_2$ by EPMA.

  • PDF

Correlation Analysis of Body Parameters between Chuna Posture Analysis System and X-ray (추나체형진단기와 단순 방사선 검사로 측정된 신체 지표들간의 상관 분석)

  • Kim, Chang-Gon;Lee, Jin-Hyun;Min, Seon-Jeong;Kim, Byung-Sook;Song, Yung-Sun;Lee, Su-Kyung;Ko, Youn-Suk;Lee, Jung-Han
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.4
    • /
    • pp.177-185
    • /
    • 2014
  • Objectives This study analyzed the correlation between body parameters measured using X-ray and Chuna posture analysis system to determine their clinical value in diagnosing and evaluating skeletomuscular diseases. Methods X-ray and Chuna posture analysis system were performed for 105 patients to measure physical characteristics such as Interacromial angle, Pelvic obliquity angle, Structural leg length discrepancy (SLLD), Midpatella-midtalus angle (MMA) and Q-angle, Anterior head translation (AHT), Anterior superior iliac spine to posterior superior iliac spine angle (ASIS-PSIS angle), Interscapular angle, Scoliotic angle and Cobb's angle. Statistical analysis using statistical analysis techniques and Pearson correlation coefficients was performed to assess the body parameters obtained by X-ray and Chuna posture analysis system. Results Significant correlations were observed between the values for Interacromial angle, Pelvic obliquity angle, SLLD, MMA and Q-angle, AHT, ASIS-PSIS angle, Interscapular angle, Scoliotic angle and Cobb's angle obtained by X-ray and Chuna posture analysis system. Significant correlations were also observed between right MMA and left Q-angle as well as between left MMA and right Q-angle. Conclusions Chuna posture analysis system can be used instead of X-ray measure body parameters and perform posture analysis in clinical practice. This study's findings are expected to serve as a basis for further research on the clinical application of Chuna posture analysis system.

Radiation Quality Analysis of Diagnostic X-ray Equipment (진단용 X선 기기의 선질 분석)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.771-772
    • /
    • 2010
  • X-ray equipment used to diagnose a patient has a big defect of a patient's exposure to radiation caused in irradiating X-ray to the human body, ICRP restricts the permissible exposure dose of the human body. A number of studies has been proceeded to reduce these exposures. In this study the high voltage generator with inverter system, which is possible to increase the generation efficiency of X-ray and to control the precise output power was produced. Also, to minimize the ripple which is possible to occur in the direct voltage that is applied to X-ray tube the propagation rectification method was applied and the radiation reproducibility and properties were evaluated to use this for the diagnosis of patient.

  • PDF

A Study of Practical and Optimized Mineral Quantification (실용적이고 최적화된 광물정량분석법 연구)

  • Son, Byeong-Kook;An, Gi-O
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.4
    • /
    • pp.227-239
    • /
    • 2021
  • A practical and effective method of X-ray powder diffraction analysis was investigated for quantitative analysis of the mineral content of natural samples. Sample mounting experiments were conducted to select the best randomly oriented powder sample mount. A comparative experiment was also made between a reference intensity ratio (RIR) method, which compares a single peak intensity with standard material, and the Rietveld method, which calculates a full X-ray diffraction pattern, to search for the effective method of mineral quantification. In addition, samples containing amorphous minerals were quantitatively analyzed by the Rietveld method and the efficiency was reviewed. As a result of the study, the optimal random orientation could be reached by the side mounting method. The Rietveld method using the full pattern of X-ray diffraction was more suitable for mineral quantitative analysis, rather than the RIR method using a specific peak. However, either method could depend on the analyst's experience in addition to analytical technique. Moreover, amorphous minerals can be quantitatively analyzed by the Rietveld method, and the analysis results make the geological analysis possible.

Analysis of Water Penetration through Pores in Spray-applied Waterproofing Membrane Using X-ray CT Images (X-ray CT를 이용한 분무식 방수 멤브레인의 공극 내 물 침투 분석)

  • Choi, Soon-Wook;Kang, Tae-Ho;Chang, Soo-Ho;Lee, Chulho;Choi, Myung-Sik;Kim, Kwang Yeom
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.211-219
    • /
    • 2017
  • The spray-applied waterproofing membrane is installed on shotcrete or concrete surface to make impermeable layer with 3-5 mm thick for the purpose of waterproofing. This study aims to determine the internal structure of a spray-applied waterproofing membrane including pores by using X-ray CT technique. Before obtaining X-ray images of the membrane specimens, a waterproof performance test was performed on the membrane specimens with a water pressure of 500 kPa for 28 days. Results show that the movement of moisture is made through micropores. This is based on the fact that the large pores inside the membrane are not saturated and the degrees of saturation of the micropores are high. X-ray image is effective for determining the pore size distribution and whether the membrane with pores contains the water However, it is necessary to pay attention to the determination of water content, since water content may vary depending on the threshold value of X-ray image analysis applied to calculate the water content.

STUDY OF ULTRALUMINOUS X-RAY SOURCES IN SOME NEARBY GALAXIES

  • Singha, Akram Chandrajit;Devi, A Senorita
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.1
    • /
    • pp.1-9
    • /
    • 2019
  • We present the results of the spectral and temporal analysis of eight X-ray point sources in five nearby (distance < 20 Mpc) galaxies observed with Chandra. For spectral analysis, an absorbed powerlaw and an absorbed diskblackbody were used as empirical models. Six sources were found to be equally fitted by both the models while two sources were better fitted by the powerlaw model. Based on model parameters, we estimate the X-ray luminosity of these sources in the energy range 0.3 - 10.0 keV, to be of the order of ${\sim}10^{39}ergs\;s^{-1}$ except for one source (X-8) with $L_X>10^{40}ergs\;s^{-1}$. Five of these maybe classified as Ultraluminous X-ray sources (ULXs) with powerlaw photon index within the range, ${\Gamma}{\sim}1.63-2.63$ while the inner disk temperature, kT ~ 0.68 - 1.93 keV, when fitted with the disk blackbody model. The black hole masses harboured by the X-ray point sources were estimated using the disk blackbody model to be in the stellar mass range, however, the black hole mass of one source (X-6) lies within the range $68.37M_{\odot}{\leq}M_{BH}{\leq}176.32M_{\odot}$, which at the upper limit comes under the Intermediate mass black hole range. But if the emission is considered to be beamed by a factor ~ 5, the black hole mass reduces to ${\sim}75M_{\odot}$. The timing analysis of these sources does not show the presence of any short term variations in the kiloseconds timescales.

Study on Correlation between the Gait Analysis Indices and Lumbar X-ray Indicators (보행과 기립위 요추 방사선 지표와의 상관성 연구)

  • Park, Jong-Han;Jeong, Su-Hyeon
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.4
    • /
    • pp.121-130
    • /
    • 2017
  • Objectives This study was designed to investigate the correlation between the gait analysis indices and Lumbar X-ray indicators. Methods 21 cases of patients who received treatment from October 2013 to February 2017 for abnormal posture were analyzed. Three indicators were measured in the lumbar spine X-ray. These indicators include Ferguson's angle, Lumbar lordotic angle, L4-5 IVD angle. Gait analysis indices were estimated by Treadmill Gait Analysis system. The data were analyzed to find out correlation between the gait analysis indices and Lumbar X-ray indicators. Spearman correlation was used. Results Ferguson's angle and Difference of gait balance of front and rear had a negative linear relationship, but there was no statistical significance. Lumbar lordotic angle and Difference of gait balance of front and rear had a negative linear relationship, but there was no statistical significance. L4-5 IVD angle and Difference of gait balance of right and left had a negative linear relationship, but there was no statistical significance. Conclusions Difference of gait balance of front and rear had strong level of a negative linear relationship with Ferguson's angle and Lumbar lordotic angle.

The analysis and design of X-ray cross sectional imaging system for PCB solder joint inspection (PCB 납땜 검사를 위한 X선 단층 영상 시스템의 해석 및 설계)

  • 노영준;강성택;김형철;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.109-112
    • /
    • 1996
  • The more integrated and smaller SMD are needed, new solder joints packaging technologies are developed in these days such as BGA(Ball Grid Array), Flip Chip, J-lead etc. But, it's unable to inspect solder joints in those devices by visual inspection methods, because they are hided by it's packages. To inspect those new SMD packages, an X-ray system for acquiring a cross-sectional image of a arbitrary plane is necessary. In this paper, an analysis for designing X-ray cross sectional imaging system is presented including the way for correcting the distortion of image intensifier. And we show computer simulation of that system with a simple PCB model to show it's usefulness in applying PCB solder joint inspection.

  • PDF

Aerial image analysis of replicated linewidths patterned by synchrontron X-ray proximity lithography (싱크로트론 X선 근접 리소그래피에 의하여 전사되어진 라인의 폭에 대한 에어리얼 이미지 시뮬레이션)

  • 이재웅;서용덕;김오윤;최보경;김희상
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.70-77
    • /
    • 1998
  • An aerial image simulator for the synchroton X-ray proximity lithography system has been developed. The modal expansion method and Rayleigh-Sommerfeld diffraction theory are used in calculating the aerial image which is formed by diffracting of the partially coherent X-ray, Experimental results of PALC(POSTECH Advanced Lithography Center) lighography system and simulated results are compared. The experimental and theoretical values of the width of replicated lines are consisted with the relative error less than ~5%. The method to determine the divergent angle of X-ray from the analysis of the width of replicated lines is given.

  • PDF

Measurement of Dose Distribution for Diagnostic X-ray (X선진단(診斷) 영역(領域)에 있어서의 심부선량분포(深部線量分布)의 측정(測定))

  • Kim, You-Hyun;Huh, Joon;Kim, Seung-Chul;Yoon, Jong-Min
    • Journal of radiological science and technology
    • /
    • v.18 no.1
    • /
    • pp.55-62
    • /
    • 1995
  • This study was performed to find out dose distribution, pdd, surface dose and off center ratio. A few articles is analysis of dose data in radiotherapy field, there is no standardized measure of an assessment of exposure dose at diagnostic radiology, yet. And authors demonstrated a new assessment measure by ion chamber, TLD and film dosimetry system. We assurance that our data is useful to quantiative analysis of exposure dose and clinical fields for reduction of radiation dose.